Server FAQ — real answers from the field

Questions sourced from Dell, Lenovo, HPE and Cisco community support threads, rewritten for clarity, each linking to the original discussion.

Frequently asked questions

What are the part numbers for the R1B (FL) and R5B (FL) risers needed for a DELL PowerEdge R770 server to install GPUs?

The part number for the R1B (FL) riser is CDTJW, and for the R5B (FL) riser, it is 0T5DV. [community thread]

What GPUs are compatible with the Dell PowerEdge T440 server?

For information on compatible GPUs, it is recommended to check the official Dell parts website or consult with their Sales team for assistance with specific models. [community thread]

What should I do if my PowerEdge R740 shows no video or keyboard response after adding memory?

First, try removing the CMOS battery for a few minutes to reset the BIOS to its default settings. Ensure that all necessary connections are secure and check the status LEDs on the mainboard to determine if the server is ready to boot. If the issue persists, further hardware diagnostics may be needed. [community thread]

What GPUs are compatible with the PowerEdge R7525 and what is the maximum power draw?

For compatible GPUs and recommended slots, consult the technical guide, specifically page 27. The maximum power draw for GPUs is detailed in the table on page 7. [community thread]

What does the error 'CPU 1 VCCIO PG Voltage Is Outside of Range' mean on a PowerEdge R760?

This error is typically associated with issues in the motherboard's voltage regulation or CPU seating. To troubleshoot, perform a power drain, check for firmware updates, and inspect the CPU for any bent pins or debris. If the problem continues, the motherboard may need to be examined. [community thread]

What are the compatible CPU upgrade options for the Dell PowerEdge R640?

A detailed list of supported processors for the R640 can be found in the technical guide provided by Dell. If you have questions about specific processors not listed, consider reaching out to customer support for assistance. [community thread]

Can I upgrade the CPUs in my Dell PowerEdge T440 to Intel Xeon Gold 6242 processors?

Yes, the Dell PowerEdge T440 with the 81VG9 motherboard supports Intel Xeon Gold 6242 processors. It is advisable to check for any necessary BIOS or firmware updates before proceeding with the upgrade. [community thread]

Why does the iDRAC display CPU speed in MT/s instead of MHz or GHz on my server?

This is a known presentation error in iDRAC9 where the CPU speed is incorrectly labeled as MT/s instead of MHz or GHz. It does not indicate a hardware or firmware issue, but rather a unit-labeling mistake in the user interface. [community thread]

Can the R760 server support two Nvidia L40 video cards?

Yes, the R760 server with dual CPUs can accommodate two Nvidia L40 GPUs, as they are double-width and within the power specifications. Ensure you have a power supply of at least 1600W and the appropriate GPU riser kit, power cables, and cooling components for optimal performance. [community thread]

What should I do if my Dell R450 shows HWC8010 and UEFI0459 errors during startup?

To resolve HWC8010 and UEFI0459 errors, first reseat the PERC 755 RAID card and any associated risers, ensuring they are in the correct slots. Next, access the BIOS/iDRAC settings to accept the current hardware configuration as valid. If the issue persists, check for firmware updates or temporarily remove the PERC card to see if the error clears. [community thread]

What is the pinout configuration for the GPU power cable DP/N: 04VPD3 on a PowerEdge R740xd?

For specific pinout details of the 04VPD3 GPU power cable, it is recommended to contact the sales department or a third-party vendor directly, as this information is not typically available in public forums. [community thread]

Is the DXD9H HDD tray caddy compatible with the PowerEdge R360 server?

Yes, the DXD9H hard drive tray caddy is compatible with the PowerEdge R360 server, as it is part of the 16th generation of PowerEdge servers. [community thread]

What parts are needed to install a GPU on a PowerEdge R750XS server?

The PowerEdge R750XS does not have a specific GPU enablement kit, and there is no documented support for GPU configurations. For detailed information, refer to the technical guide provided by the manufacturer. [community thread]

What power cable is needed for the NVIDIA Tesla V100 32GB in a PowerEdge R740?

The required power cable for the NVIDIA Tesla V100 32GB in a PowerEdge R740 varies based on the specific GPU configuration. It is recommended to consult with the sales department or refer to the manufacturer's documentation for the appropriate riser and power kit details. [community thread]

Why does my Dell R640 show a memory incompatible error when using mixed DIMMs?

The issue may arise from differences in memory rank, firmware, or PCB revisions between the original and new DIMMs, even if the part numbers match. To troubleshoot, try booting with one module from each set in different CPU slots, and consider updating the BIOS and iDRAC firmware. If problems persist, you may need to return the new modules for ones that match the original revision. [community thread]

What should I do if my Dell R7525 server gets stuck at the IDRAC initializing screen with solid DS0 and DS3 LED lights?

First, ensure that the CPUs and memory modules are properly seated and compatible. Clear the NVRAM by using the onboard jumper or removing the battery to reset the BIOS settings. If the issue persists, it may indicate a fault with the motherboard. [community thread]

What NVMe expanders are compatible with the R740XD's 0P1MJ3 backplane?

The 0W0DNK NVMe expanders are not compatible with the 0P1MJ3 backplane. You should use the 0235NK expanders, as they are specifically designed for this configuration, allowing for optimal performance with 12 NVMe drives. [community thread]

What should I do if I encounter a memory error when installing RAM in a Dell PowerEdge R750xs server?

If you receive a memory error, try rearranging the RAM modules to different slots, as one of the DIMMs may be faulty. Additionally, ensure that your BIOS and iDRAC are updated to the latest versions, as this can sometimes resolve compatibility issues. [community thread]

What components are necessary for installing an NVIDIA L4 GPU in a PowerEdge R760xd2 server?

To install an NVIDIA L4 GPU in a PowerEdge R760xd2, you will need Riser Config 3A, a GPU enablement kit (part number 470-BBWW), and the NVIDIA L4 GPU itself (part number 490-BJRQ). Ensure that your server's BIOS and iDRAC are updated, and a power supply of 1100W or more is recommended for stable operation. [community thread]

Is the H750 PERC controller compatible with the PowerEdge T440?

Yes, the H750 PERC controller is compatible with the PowerEdge T440, provided that you use the appropriate cables and only pair it with PERC 11 controllers. Avoid mixing it with older PERC models to ensure proper functionality. [community thread]

What should I do if my PowerEdge R740xd is stuck at boot after switching from RAID to HBA mode?

To resolve the boot issue, revert the PERC controller back to RAID mode via iDRAC and perform a cold power cycle for 30 to 60 seconds. After rebooting, access the System Setup to delete any old UEFI boot entries, clear all configurations in the PERC settings, and ensure that your BIOS, iDRAC, and PERC firmware are updated before switching back to HBA mode. [community thread]

What should I do if I encounter a memory incompatible error after installing RAM in a Dell PowerEdge T440 server?

Verify that the RAM modules are installed according to the server's memory configuration guidelines. Ensure that the DIMMs are compatible and properly seated as per the specifications provided in the installation manual. [community thread]

What do the LED codes on the R660 motherboard indicate when the server fails to boot?

The LED codes on the R660 motherboard can signal various issues, such as a 5V switch fault or problems with connected USB devices, iDRAC cables, or the rear I/O card. To troubleshoot, perform a flea power drain, clear the NVRAM, and test with only the minimum components necessary for POST. If the server still does not boot, further inspection of the components may be required. [community thread]

Why isn't a second CPU recognized after reinstalling it in a PowerEdge R750?

This is almost always a seating issue — power down, remove the processor and heatsink, then reinstall and torque all four corner screws evenly. If it still isn't detected in iDRAC, update BIOS/iDRAC firmware and run the Lifecycle Controller's repurpose option so the CPLD re-registers the second socket. [community thread]

How can I enable TPM on a Lenovo SR650 running ESXi 7.0 without disrupting my current setup?

To enable TPM on your Lenovo SR650, refer to the technical documentation available at Lenovo's website, which provides guidance on configuring TPM with VMware environments. Ensure to follow the steps carefully to minimize any potential impact on your existing system. [community thread]

What should I do if my 16GB RAM is not functioning in my SR550 server?

To troubleshoot the issue, try resetting or swapping the problematic DIMM with a functioning one to determine if the issue lies with the DIMM or the slot. If the server is still under warranty, contact customer support for assistance. [community thread]

How can I configure RAID 1 with NVMe drives on the SR650 V2 server?

Ensure you have the appropriate NVMe RAID FoD license, as only Intel-branded NVMe SSDs are supported for RAID configurations. Additionally, verify that you are using Lenovo-qualified NVMe drives for compatibility and consider updating your firmware with the latest Lenovo Bootable Media Creator ISO. [community thread]

Why is one of my RAID 1 arrays showing 0 GB capacity on my ThinkSystem SR630 V3?

To resolve the issue of a RAID array displaying 0 GB capacity, ensure that the Xclarity Controller (XCC) and UEFI firmware are updated to the latest versions. If the problem persists, you can refresh the inventory by using the OneCLI command or by making a minor change in the BIOS settings and rebooting the server. [community thread]

Why is my MicroSD card not recognized in the ThinkSystem ST50 V3?

The ThinkSystem ST50 V3 does not officially support the use of a MicroSD card, despite having a slot for it. To confirm if the server recognizes a MicroSD card, check the Remote RDOC menu in the XCC2 GUI; if the card is supported, the available size will increase beyond the default 100MB. [community thread]

What should I do if my SR 665 server crashes after an SSD failure?

To resolve the issue, replace the faulty SSD promptly to avoid data loss. Additionally, check if your server has a RAID card and provide the current array level, along with FFDC logs for further diagnosis. [community thread]

What should I do if my Lenovo ThinkSystem V2 server reports a low CMOS battery during operation?

If your server indicates a low CMOS battery, it is necessary to replace the battery. Additionally, updating the firmware may help enhance battery performance. [community thread]

How can I resolve missing base system drivers on an SR650 V3 server running Windows Server 2022?

To fix missing base system drivers, first check the hardware IDs in Device Manager to identify which drivers are needed. Download the latest compatible drivers from the Lenovo Support website for the SR650 V3 model, and consider using Lenovo XClarity Essentials for assistance in driver installation. [community thread]

What should I do if my server is not recognizing all installed NVMe drives?

First, verify that the NVMe drives in the affected bays are properly seated and connected. Restarting the XClarity Controller (XCC) may also help restore the drive inventory. Additionally, ensure that your server's firmware is up to date and check the VMD settings in the BIOS/UEFI for correct configuration. [community thread]

What is the maximum SEL log capacity for the SR630 V3 server?

The SR630 V3 can accommodate up to 2,046 SEL logs when the IPMI SEL log wrapping feature is turned off. [community thread]

What can I do if my ThinkSystem SR630 V2 has slow disk speeds?

If you're experiencing low write speeds of 15-20 MBps, this may be expected due to the cacheless nature of the 5350 controller, which operates in write-through mode. To potentially improve performance, you can enable the drive cache using the MegaRAID BIOS interface or storcli commands. For significant speed enhancements, consider upgrading to a controller with a cache module. [community thread]

How can I upgrade the BIOS on my ThinkSystem SR530 if I need an intermediate version?

To upgrade the BIOS on your ThinkSystem SR530, first download the required intermediate version TEE180J from the following link: https://datacentersupport.lenovo.com/us/en/downloads/DS560929. After installing TEE180J, you can proceed to upgrade to the latest version. [community thread]

How can I enable Intel VT-d for virtualization on the SR650 V2 server?

To activate Intel VT-d, reboot the server and press F1 to access the UEFI Setup. Navigate to System Settings, then Operating Modes, set it to Custom Mode, and save the changes. Next, go to Devices and I/O Ports, enable Intel VT for Directed I/O (VT-d) and SR-IOV, then save and reset the system. [community thread]

Is the NVMe backplane upgrade compatible with the ThinkSystem SR650 V3 server?

Yes, the ThinkSystem SR650 V3 server supports upgrading to an NVMe backplane, allowing for the use of NVMe SSDs and M.2 drives with the appropriate adapter. Ensure that the backplane is specifically designed for this model and that all firmware and drivers are current for optimal performance. [community thread]

Why does my ThinkSystem ST650v3 server hang at the Windows logo after adding a virtual drive to the 9350-16i RAID controller?

To resolve this issue, check the BIOS settings to ensure the m.2 NVMe drive is set as the primary boot device and that the boot mode for the RAID controller is configured to UEFI. Additionally, update the firmware and drivers for the RAID controller and verify the RAID configuration to ensure it does not conflict with the boot drive settings. [community thread]

Do I need a True Sine Wave UPS for my ThinkSystem SR250V3 server?

Yes, a True Sine Wave UPS is essential for the ThinkSystem SR250V3. Using a Simulated Sine Wave UPS can lead to instability and potential damage, as the server's power supplies cannot correct poor quality AC input. [community thread]

What should I do if my Lenovo ThinkSystem SR530 shows error code FQXSPPW0063M after a BIOS update?

To troubleshoot this issue, collect the Service Data (FFDC log) from the server for further analysis. It is also recommended to consult with Lenovo support for assistance, as the error may indicate a system voltage fault. [community thread]

How can I enable PCIe Bifurcation in the BIOS of a ThinkSystem SR530?

To enable PCIe Bifurcation, ensure your system firmware is updated to the latest version. Check the UEFI Setup under System Settings > Devices and I/O Ports for PCIe slot configuration options. If these options are unavailable, your current hardware may not support manual bifurcation, and you might need to use a compatible active dual-NVMe adapter. [community thread]

What should I do if the Lenovo UpdateXpress fails with a ping error during firmware updates?

Check the settings in the XCC GUI to ensure that 'IBM Over KCS Access' and 'Ethernet over USB' are both enabled. Additionally, consider reinstalling the BoMC utility and following the official guide step by step, ensuring that 'Enable Task Auto Run' is selected and the BMC access information is correctly configured. [community thread]

Why is the Broadcom OCP not detected in my SR655 V3 server?

First, ensure the OCP card is properly seated and check for any visible damage. If the card is still unrecognized, test it in a different compatible server to determine if the issue lies with the OCP itself. [community thread]

What is the recommended procedure for updating UEFI/BMC firmware on an older server model?

To update UEFI/BMC firmware on an older server, first identify your server model and current firmware versions. Download the latest UpdateXpress System Pack for your model and check for any prerequisite updates. Use the bootable UpdateXpress tool for a more reliable update process, and ensure to follow any specified order for updates, rebooting and verifying after each phase. [community thread]

Where can I find the latest firmware for the ThinkSystem SR635 V3 server?

The latest LXPM firmware version 4.21.05 can be downloaded from the Lenovo support site, although it may not appear correctly on some machine type pages. If you encounter issues, you can still access it through the direct link provided or by using the BOMC download option. [community thread]

Why can't I install Windows Server 2025 on my SR650 v3 with RAID1 configuration?

Ensure that you are using UEFI boot mode, as Windows Server 2025 requires it and does not support Legacy mode. Additionally, make sure to import the Intel software RAID driver during installation, or consider using the LXPM deployment method, which automatically includes necessary drivers. [community thread]

What memory upgrades are compatible with the Lenovo SR650 server?

For the Lenovo SR650, you can use the ThinkSystem 64GB TruDDR4 2933 MHz RDIMM (Part No 01KR356) and the ThinkSystem 128GB TruDDR4 2933 MHz 3DS RDIMM (Part Nos 02JG082 and 02YH249). Ensure that all installed memory modules are of the same type, rank, and capacity to achieve optimal performance. [community thread]

How can I resolve issues with configuring RAID on a ThinkSystem SR630 V3 with NVMe drives?

To successfully configure RAID with the 940 RAID controller, ensure you are using U.3 NVMe drives, as other types are not supported. Additionally, verify that the internal cabling connects the RAID controller to the backplane without any conflicts from onboard NVMe connections. Lastly, adjust the backplane speed settings to U.3 x1 lane speed using the XCC2 GUI. [community thread]

How can I resolve the fqxspca0016m error code on my SR650 V2 server?

To fix the fqxspca0016m error, ensure that your server has the correct number of fans installed based on its configuration—typically 6 fans for systems with 2 CPUs. If you have already installed the correct number of fans, reboot the XCC for fan detection and check that the fans meet the thermal requirements. If issues continue, collect service logs from the XCC WebGUI and upload them for further analysis. [community thread]

How can I clear the debug logs on a THINKSYSTEM SD530 server after a factory reset?

To clear the old event logs, access the XCC web interface and use the option available in the designated tab. Keep in mind that a factory reset will restore the XCC configuration to default settings, but it does not remove the debug logs, which are intended for troubleshooting and cannot be manually deleted. [community thread]

How many power supplies are needed for the ThinkSystem SR780a V3 servers in an N+N configuration?

In an N+N setup, each group of power supplies can manage the entire load, but the adequacy of 4 power supplies depends on their wattage and the overall power requirements of the system. It's important to review the specifications of the power supplies to ensure they can handle the peak consumption of all components. [community thread]

Why does my SR250 V3 server power off unexpectedly?

Random shutdowns can be caused by overheating, power supply unit failure, loose internal connections, unstable power environments, software issues, or motherboard defects. To troubleshoot, check the server's temperature and logs, test the power outlet, reseat internal power cables, and ensure firmware is up to date. [community thread]

What should I do if my server shows a critical sensor drive mismatch error after an XCC update?

This issue may arise after updating to XCC version 5.50, which includes a fix for drive mismatch reporting. Check the physical connections of your drives and ensure that the controller is installed in the correct PCIe slot, as improper placement can lead to detection errors. If the problem persists, consider updating the controller firmware or contacting support for further assistance. [community thread]

What does the security warning for SNMP V3 on the SR630 V3 indicate?

The warning appears because enabling SNMP V3 in Standard Security Mode may use non-FIPS compliant cryptography. While the functionality is supported, it is advisable to use Enhanced Mode for stronger security standards in production environments. [community thread]

How can I reset the BIOS password on a Lenovo ST550 if I've forgotten it?

To regain access to the BIOS, consider rolling back the UEFI firmware to a previous version. Alternatively, you can create a bootable media using BoMC, boot from it, and select the option to load UEFI/BMC defaults to reset the password. For detailed instructions, refer to Lenovo's support documentation. [community thread]

How can I resolve the unknown device issue on Windows Server 2016 for the SR630 V3?

The device ID ACPI0017 relates to the Compute Express Link (CXL) Root Object, which is not supported by Windows Server 2016. This means the device will show as unknown in Device Manager, but it can be safely ignored as it does not affect system performance. For optimal compatibility, consider using a certified operating system. [community thread]

Why does the UpdateXpress System Pack report no components to update on my ThinkSystem server?

Ensure that the XCC connection settings are properly configured for the UpdateXpress System Pack. Check that IPMI over KCS is enabled and that the necessary network settings are correctly set up in the BMC Configuration. Additionally, verify that the UXSP packages available for your specific machine type and operating system include the updates you are expecting. [community thread]

How can I update the BIOS on my server to the latest version without multiple incremental updates?

To update the BIOS to the latest version in one go, use the BoMC tool and ensure you select the option to check for the latest individual updates from the Lenovo support website. If there are no dependencies, this should allow the update to complete in a single attempt. [community thread]

Can I upload multiple firmware files at once for the SR630 server upgrade?

No, the firmware upgrade for the SR630 server must be done one file at a time through the XCC web interface. Other methods may be available, but issues with the server could affect the upgrade process. [community thread]

What should I do if my Think System SR650 shows a disk in JBOD state with a critical health status?

First, prioritize backing up any accessible data from the disk. Then, check the disk's role in the system using the XCC interface to determine if it's part of a RAID array or a standalone JBOD. If it's part of a RAID, replace the failed disk and allow the array to rebuild; if it's standalone, replace the disk and reconfigure it as JBOD or a RAID 0 array, then restore your data. [community thread]

Why is the PCIe Bifurcation setting not visible in my Lenovo SR650 server's BIOS?

The PCIe Bifurcation option is not available in the UEFI settings for the Lenovo SR650 Gen 1, as it is managed automatically based on the riser card and installed adapters. With the ThinkSystem 2U x8/x8/x8 PCIe Riser 1, the lanes are pre-configured for x8 operation, and no additional settings are necessary. [community thread]

How can I resolve issues updating the BMC firmware on my SR650 server?

To address BMC firmware update problems, first verify that the firmware version you are attempting to install is compatible with your server, as some versions may be OEM-specific and unavailable on public download sites. If compatibility is confirmed, consider using the latest version of Lenovo XClarity Essentials for the update, and check for any necessary system updates using the Lenovo Vantage App. [community thread]

How can I verify VMware ESXi compatibility for the Lenovo SR650 server?

To confirm compatibility, check the Lenovo support site and the VMware I/O recipe for the SR650. The Emulex VFA5.2 Adapter may not be listed in the latest recipes, but it is included as an inbox driver in ESXi according to Broadcom's compatibility page. For the latest drivers and firmware, visit the Lenovo Datacenter support site and search for your machine type. [community thread]

Can I use any SAS SSD model with the SR630 V2 server?

The SR630 V2 server is compatible with SAS SSDs, but it's advisable to use drives that are factory-shipped for the best performance and compatibility. For specific storage options, refer to the manufacturer's documentation. [community thread]

What should I do if my server displays a critical sensor voltage fault and won't power on?

To troubleshoot the issue, reduce the server to its minimum configuration by using only one processor, one DIMM, and one power supply, without any additional adapters or drives. If the server powers on successfully, gradually reintroduce components to identify the faulty part. [community thread]

What should I do if my Thinksystem SR630 server won't start after changing the jumper settings?

First, revert the jumper J181 back to Pin1-2 and power on the server. Then, access the UEFI settings by pressing F1 and navigate to BMC Settings to reset to factory defaults, which will restore the default user ID and password. [community thread]

How can I obtain SATA power for the Lenovo ThinkSystem ST550?

The Lenovo ThinkSystem ST550 does not provide standard SATA power leads from the power supply. Instead, you need to use the proprietary Tape & ODD power harness, specifically the 01KN091 or 03HC016 cables, to supply power to SATA drives. [community thread]

Can I replace the SAS backpanel with an NVMe backpanel on the SR650 v3 server without issues?

Yes, the SR650 v3 server supports various configurations for front drive bays, including NVMe backpanels. Ensure that the RAID card and NVMe cables are properly configured with the new disk panel. [community thread]

What should I do if the remote video on my SR650 V3 server is not displaying correctly?

If the remote video via Xclarity is not showing the login screen, first ensure that you are using the latest firmware for the XCC2. If the issue continues, try accessing the XCC2 from a different computer, restarting the XCC2, or performing an AC cycle by unplugging the server. If none of these steps resolve the issue, consider reapplying or updating the XCC2 firmware. [community thread]

Why is Windows Server 2022 installation failing on my SR650 V3 server with a RAID 540-8i adapter?

The installation may be failing due to an incorrect driver being loaded for the RAID controller. Ensure you download the appropriate driver for Windows Server 2022 from the Lenovo support site, and verify that your UEFI, XCC, and LXPM firmware are updated to the latest versions. After updating, reboot the server and attempt the installation again. [community thread]

How can I verify the compatibility of the Lenovo SR650 V2 server with VMware ESXi 8.0?

To confirm compatibility, refer to the Lenovo VMware Recipe link for the SR650 V2, which provides a detailed matrix. Ensure that you are using the latest drivers and firmware for your adapters, and check for any specific version updates, such as the ThinkSystem RAID 930-8i adapter. [community thread]

How can I apply firmware updates for the R340 server if the Nautilus utility is not available?

You can attempt to extract the firmware from the Windows driver version using a tool like 7-ZIP. Additionally, check the Dell support page for the R340 to find any available firmware updates that may not be prominently listed. [community thread]

Why do my 4TB SSDs work after a power cycle but fail to initialize after a reboot on a Dell R640 with a PERC H730P Mini?

This issue may arise from a compatibility problem between the SSDs and the RAID controller, particularly during reboot sequences. To troubleshoot, ensure that both the PERC H730P Mini and the SSDs have the latest firmware updates, and verify if the SSDs are officially supported by Dell. Additionally, consider adjusting BIOS settings, checking power connections, or testing different RAID configurations. [community thread]

How can I obtain a GPU installation kit for the PowerEdge R7625 and what is the correct kit number?

To acquire the GPU installation kit for the PowerEdge R7625, it is recommended to contact the customer support hotline for a quote tailored to your system. The installation cable kit number is typically 06KX6, which includes specific cables such as 0M6CK, GPN9K, 0DK9Y, and MD9J9. [community thread]

What CPU upgrades are compatible with the Poweredge T430 when using the KX11M motherboard?

The Poweredge T430 with the KX11M motherboard supports several E5-2600 v4 processors, including the E5-2660 v4, E5-2650 v4, and E5-2630 v4, among others. It's important to note that the motherboard may have limitations on power draw, so consider using CPUs with lower TDP ratings, such as the E5-2650L v4. Additionally, upgrading to a higher wattage PSU, like the 1100W unit, may help support more demanding configurations. [community thread]

How can I install an NVMe drive in a Dell R340 server with 3.5-inch bays?

To install a 2.5" NVMe SSD in a 3.5" hot-swap bay, you will need a 3.5" LFF tray and a 2.5"-to-3.5" adapter. However, for proper NVMe functionality, it is recommended to use a PCIe adapter card instead of relying on the drive bays, as NVMe drives require a different connection type. [community thread]

What power supply is compatible with the PowerEdge T340?

The compatible power supply for the PowerEdge T340 is part number G9TRF, which is a 350W unit. Ensure that you check for the correct connector type, as the T340 may have variations with 8-pin and 12-pin connectors. [community thread]

How can I add NVMe support to a Dell R740XD server?

The Dell R740XD chassis does not support NVMe drives in a 12 + 4 configuration, which means there is no available option to add NVMe capabilities to this server model. [community thread]

What should I do if my PowerEdge R7515 shows a POST error?

To address a POST error on your PowerEdge R7515, ensure that the firmware is updated to the latest version and run the built-in hardware diagnostics by booting into the LifeCycle Controller. Take note of any errors that arise during the diagnostics for further investigation. [community thread]

What is the part number for the 8-pin GPU cable compatible with the A100 GPU in an R760xa server?

The appropriate part number for the 8-pin GPU cable for the A100 GPU in an R760xa server is 191JG, which is the GPU PUCK cable. You can refer to the cabling guide for additional details. [community thread]

How can I manage fan speeds on a Dell R740XD2 when they are stuck at high RPMs?

To address high fan speeds on the Dell R740XD2, ensure you are using a supported operating system, as Flatcar is not officially validated for this server model. Consider switching to a supported OS like Ubuntu or Red Hat, which may allow for better fan control. If you continue to use Flatcar, be aware that Dell does not provide support for issues related to it. [community thread]

What should I do if my Dell T640 server shows a memory error after CPU installation?

If you encounter a memory error after changing CPUs, first ensure that the memory modules are correctly seated and populated in the appropriate slots. Check for any bent pins on the CPU socket, as this could indicate a problem. If issues persist, consider isolating the components to determine if the memory or CPU is faulty. [community thread]

How can I synchronize the firmware versions on my R7725 servers with ConnectX-6 Dx cards?

To align the firmware versions, download the July 2025 Server Update Utility (SUU) for your R7725 servers. This utility will help you update the firmware to version 22.42.1000 for the ConnectX-6 DX cards. Follow the provided instructions to mount the ISO and execute the update. [community thread]

What should I do if I encounter a SUP0528 error while updating firmware on a Dell R630 server?

To resolve the SUP0528 error, ensure that the Intel 10G X710 rNDC network card has SFP modules connected. Additionally, you may want to disable and then re-enable the Lifecycle Controller to see if that helps with the update process. [community thread]

How can I determine if my Dell R7525 server chassis is OEM or not?

To identify if your R7525 chassis is OEM, check the service tag on the Dell support page. If it is OEM, the support page will explicitly indicate this. [community thread]

How can I disable the liquid cooling setting on a PowerEdge server?

To disable the liquid cooling setting, you can use an undocumented OEM IPMI command with ipmitool. Ensure you have root/admin privileges, and after executing the command, reboot both the iDRAC and the host operating system to apply the changes. [community thread]

Why is my Dell PowerEdge T440 not showing partitionable GPUs for vGPU on Windows Server 2025?

The issue may stem from driver compatibility, so ensure you have the latest Nvidia drivers specifically certified for Server 2025. Additionally, check that SR-IOV is enabled in the BIOS and that a valid Nvidia vGPU license server is accessible. If problems persist, consider testing with an earlier version of Windows Server or contacting Nvidia support for further assistance. [community thread]

What should I do if my PowerEdge R330 server fails to start after a BIOS update was interrupted by a power outage?

Try disconnecting the power cables and holding the power button for about 30 seconds to clear any residual power. If that doesn't work, reset the BIOS settings by clearing the NVRAM on the motherboard. Additionally, remove all non-essential components and peripherals, and if necessary, perform a BIOS recovery using a USB drive with the recovery file. [community thread]

Is it safe to update the BIOS and iDRAC firmware on a PowerEdge R6525 server, and which should be updated first?

It is generally safe to update both the BIOS and iDRAC firmware to the latest versions. It is recommended to update the iDRAC firmware before proceeding with the BIOS update. [community thread]

Where can I find the supported hardware components for Dell R430, R440, R730, and R740 servers?

Documentation for supported hardware components for the Dell R430, R440, R730, and R740 servers can be found in their respective technical guides. For detailed specifications, refer to the manuals available on Dell's support website, or contact the sales department for information on any unsupported hardware. [community thread]

Why can't I access iDRAC or SSH on my Dell R330 server?

Ensure that the iDRAC and BIOS firmware are updated to the latest versions. If you have an iDRAC Enterprise license, connect directly to the iDRAC Dedicated port; otherwise, use one of the LOM ports. Test connectivity by connecting a notebook directly to the server and verifying that both devices are on the same subnet. [community thread]

Why is my Dell T430 not displaying video output with the E5-2699 V3 CPU?

The E5-2699 V3 processor is not officially supported for the Dell T430, which may lead to compatibility issues such as the lack of video output and iDRAC not recognizing the CPU. It is recommended to use one of the validated processors for the T430 to ensure proper functionality. [community thread]

What cables and components are needed to retrofit an R440 server for NVMe support?

For retrofitting the R440 to support NVMe drives, it's advisable to refer to the user manual for accurate cabling instructions. A PCIe extender card may be necessary if utilizing the SAS drive slots, and ensure that the SAS cables are of adequate length to connect to the HBA card. [community thread]

Can I downgrade the firmware of an X710 network interface card from version 17.5.10 to an earlier version like 16.5.20?

Downgrading the firmware of the X710 from version 17.5.10 to 16.5.20 is not supported and will likely fail. It is advisable to check the manufacturer's documentation for any specific downgrade procedures or limitations. [community thread]

What should I check if my NVIDIA Tesla P40 GPU is not recognized in a PowerEdge R740 server?

Ensure that the GPU is properly powered by installing the necessary power cable (part # 4VPD3) from the motherboard to the GPU. It's recommended to use a complete GPU support kit for the R740 to ensure all components for detection and thermal management are included. Additionally, verify the configuration by testing with only one GPU and checking iDRAC for any power initialization errors. [community thread]

What power cable is needed to install a Nvidia A100-SXM4-40GB in a R760 server?

To connect the Nvidia A100-SXM4-40GB GPU in a R760 server, you will need the appropriate power cable. The correct part numbers to look for are 9PVH2 for Riser 4 and CPH58 for Riser 1, but it's advisable to verify compatibility before purchasing. [community thread]

What does the PCI1318 error mean on a T440 server and how can it be resolved?

The PCI1318 error on a T440 server may indicate an issue with the Broadcom network interface cards when using kernel versions greater than 6.5. Disabling these network cards in the system BIOS can allow the server to boot without errors. Alternatively, replacing the network card with a compatible one can also resolve the issue. [community thread]

What NIC card and DVD/RW drive are compatible with the R550 server?

Both a NIC card and a built-in DVD/RW drive can be used with the R550. To ensure compatibility, check the Dell Support page with your server's service tag for a list of supported hardware, or refer to the official specification sheet for detailed options. [community thread]

Why can't I see my PCIe storage card drives as boot options in the R740xd?

Ensure that the PCIe storage card is compatible with the R740xd, as only specific models are validated for this server. Additionally, check the BIOS settings to confirm that the boot mode is correctly configured. [community thread]

Why does my R440 reboot when the UPS switches to battery power?

The reboot may be due to the UPS outputting a simulated sine wave, which can cause the R440's power supply to lose sync and restart. Ensure the UPS provides a pure sine wave output and has a transfer time of less than 4 ms. Additionally, check for firmware updates for both the UPS and the R440. [community thread]

Can I add U.2 NVMe drives to an R6615 server with an H755 SAS controller?

No, the H755 SAS controller is not compatible with NVMe drives, even if the backplane supports them. You will need to use a dedicated NVMe controller for this configuration. [community thread]

What should I do if the Riser 1A length interferes with the PERC H330 mini in my R740XD server?

Consider using a different riser slot, such as Riser 2 or 3, for your GPU installation. Additionally, ensure you have the necessary GPU enablement kit components to facilitate proper installation. [community thread]

Where can I find a block diagram for the R540 motherboard?

A public block diagram for the R540 motherboard is not available. However, you can access the Field Service Manual by visiting the Dell support website, logging in with your service tag, and navigating to the Documents section. [community thread]

How can I disable the third-party PCI fan response on an R640 server?

To turn off the default fan speed response for a third-party PCI card, use the command 'racadm set system.thermalsettings.ThirdPartyPCIFanResponse 0'. If you encounter an 'Invalid object specified' error, ensure that your iDRAC firmware is up to date and that you are using the correct command syntax. [community thread]

What could cause my T640 server to restart and burn out an H100 GPU?

The T640 server is not compatible with H100 GPUs due to its insufficient power capacity and PCIe generation limitations. The server can only support GPUs with a maximum power consumption of 300W, while the H100 requires at least 350W and is designed for Gen 5 PCIe, which the T640 does not support. [community thread]

What should I do if my Dell PowerEdge T140 server shows an IDRAC RAC0501 error and I can't access the disks?

The RAC0501 error suggests a communication problem between the iDRAC and the storage controller. Start by updating the iDRAC firmware, system BIOS, and storage controller firmware. Additionally, verify the storage controller's status during boot, ensure it is properly seated, and check iDRAC settings for correct storage configuration. [community thread]

Is the 64GB 2RX4 DDR4 RDIMM 3200 MT/s compatible with the Poweredge R640 using Intel Xeon Gold 6230 processors?

The 64GB 2RX4 DDR4 RDIMM 3200 MT/s is not compatible with the Poweredge R640 when using Skylake CPUs. Please verify compatibility with your specific server configuration before purchasing. [community thread]

What can I do if my USB keyboard is experiencing input lag in the BIOS of a Dell PowerEdge C6320?

If you're encountering intermittent keyboard input in the BIOS, try using a different USB keyboard to see if the issue persists. Additionally, ensure that the USB settings are configured correctly, as some systems may have legacy USB options that can affect performance. [community thread]

Are Micron 9200 MAX 3.2TB drives compatible with R440 and R640 servers?

Both the R440 and R640 servers can support up to x8 U.2 NVMe SSDs with the appropriate storage controller. Ensure that your Micron 9200 MAX drives are U.2 NVMe models, as they are compatible for use in both servers. [community thread]

What is the part number for the TPM 2.0 chip in a T340 server?

The part number for the TPM 2.0 chip in a T340 is 461-AAEN. For availability in your area, it's recommended to reach out to the spare parts sales team. [community thread]

What should I do if my PowerEdge R430 freezes during shutdown while running VMWare ESXi?

The issue may be related to the CMOS battery, which can be replaced easily with a standard CR2032 coin cell. Additionally, access the LifeCycle Controller (LCC) during boot to check for errors in the LCC log and run hardware diagnostics. If possible, also review the iDRAC logs for any relevant error messages. [community thread]

Are T330 HDD caddies compatible with the T360 model?

Yes, the HDD caddies from the T330 are compatible with the T360. Specifically, the DXD9H and WH5D2 parts can be used interchangeably between these two server models. [community thread]

Why am I getting a memory module error after replacing my T330's RAM?

The issue may arise from using non-certified memory modules. It is advisable to use Dell-certified parts to ensure compatibility and avoid errors. [community thread]

How can I update the firmware on a refurbished R530 server?

To update the firmware on your R530 server, access the iDRAC interface using the default username 'root' and password 'calvin'. If necessary, you can reset the iDRAC by pressing the System Identification button on the front of the server or using the racadm racresetcfg command. For detailed instructions on firmware updates, refer to the official Dell support documentation. [community thread]

What is the part number for the right ear of a PowerEdge R340 server?

The right ear for the PowerEdge R340 has two part numbers: the original is C0XH4, and the version 2 is P6CV8. [community thread]

How can I identify and replace a failed drive in a PowerEdge R540 or R550 server?

To identify the failed drive, collect a Technical Support Report (TSR) that includes storage logs, which can provide insights into the drive's status. If the drive rebuild process is unsuccessful, you can replace the drive by following the hot-swapping procedure, ensuring to verify the correct drive using the server management interface. [community thread]

What is the optimal memory configuration for an R830 server with four CPUs?

For the best performance in an R830 server, ensure that memory is evenly distributed across all CPUs. A symmetrical configuration, such as using an equal number of 32GB and 8GB sticks in each memory channel, can enhance memory performance significantly. [community thread]

What power supply units are compatible with the PowerEdge T430?

The PowerEdge T430 is compatible with several redundant power supply units, including VKDD2, GRTNK, and 2FR04. Additionally, you can use substitutes such as TH1CT, 9338D, HDV6P, and YGF8T. [community thread]

Can the Dell PowerEdge R650 be configured with 10 NVMe U.3/U.2 drives and 2 SATA drives without a RAID controller?

Yes, the Dell PowerEdge R650 can support this configuration using the S150 PERC software controller, which does not require a hardware RAID card. For software RAID, ensure that you are using compatible Dell NVMe drives and check the specifications for any additional requirements. [community thread]

Why is my U.2 drive not recognized in my Dell R740 server?

The U.2 drive may not be detected because it is not a Dell-certified component, which can lead to compatibility issues with the server's controller. For optimal performance and support, it is recommended to use drives that are certified by Dell. [community thread]

What cables are needed when replacing the backplane and controller in a Dell R650 server?

When replacing the backplane and controller in a Dell R650 server, it's important to note that the necessary cables may not be included with the new components. It is recommended to contact local support or raise a ticket to ensure you receive the correct cables for your setup. [community thread]

What should I do if my Poweredge T340 won't boot after being dropped?

If your T340 is not booting and shows a failsafe mode indication, first remove any recently added hardware. Then, perform a power drain by disconnecting all cables and holding the power button for 20 seconds. After waiting for three minutes, reconnect the NIC and power, allowing two minutes for the system to initialize before turning it on. [community thread]

Which power cable do I need for a 16-pin (12VHPWR) GPU in a PowerEdge R750?

The standard R750 GPU power kit ships with 12-pin to 8-pin and 12-pin to dual 6+2 cables, which don't fit 16-pin cards. Dell offers several GPU installation kits for the R750 keyed to the specific GPU model, so the right kit part number depends on which card you're installing — check the kit matched to your GPU before ordering. [community thread]

What are the limitations for using a single H100NVL GPU in the R760XA server?

The R760XA server requires a minimum of two H100NVL GPUs for proper operation, as it is designed for optimized GPU support. Installing a single GPU may lead to boot errors and complications during hardware upgrades. It is advisable to consult with a sales engineer to ensure the configuration meets your needs. [community thread]

Can I replace the motherboard of a Dell Poweredge R640 with any compatible version, or do I need the exact model with DP/N 0PHYDR?

You can use any compatible motherboard for the Poweredge R640, but it's advisable to stick with the same version or a newer revision to ensure full feature support. The PCIe layout should remain consistent across all motherboards for this model. [community thread]

Why are my NVMe drives not recognized by Ubuntu Server on a Dell PowerEdge R6625?

Ensure that you are using the correct controller for NVMe drives, as some configurations may require a specific controller like the Boss controller for booting. Additionally, verify that the RAID settings are properly configured and that the Ubuntu installation supports the NVMe drivers for your specific setup. [community thread]

What cables are needed for an H755N Front NVMe RAID card in a PowerEdge R650xs server?

The H755N requires NVMe-specific cables, which are different from those used for SAS PERC cards. Ensure that your server's configuration supports the necessary backplane for the H755N, as it typically accommodates specific drive setups. [community thread]

How can I resolve the UEFI0401 and UEFI0339 errors when upgrading RAM on a Dell PowerEdge R760xs?

To address these errors, ensure that your RAM modules are installed in the correct slots designated for a single processor configuration, specifically in CPU 1 slots. Additionally, verify that the RAM specifications are compatible and clear any stale hardware errors in the iDRAC by powering down the server, draining residual power, and clearing the system event log. [community thread]

How can I troubleshoot PCIe device detection issues on a Dell PowerEdge T360?

Ensure that the server's BIOS is updated to the latest version, as compatibility can be affected by outdated firmware. Additionally, check the card's specifications for compatibility with the server and verify that any required settings, such as ASPM, are correctly configured. [community thread]

What should I do if my PowerEdge T140 fails to boot after a BIOS update when using a PCIe graphics card?

If your T140 does not boot after updating to BIOS 2.19 with a PCIe graphics card connected, try using a monitor connected to the onboard video output instead. Alternatively, reverting to BIOS version 2.18 may resolve the issue, as the system does not officially support GPUs. [community thread]

Why can't I achieve PXB communication between two NVIDIA L40S GPUs in my PowerEdge R760xa?

The R760xa's architecture does not support PXB communication between the GPUs in slots 36 and 38, as they are connected to separate CPU root ports. This configuration results in NODE communication instead of the desired PXB, since there is no available riser that allows both GPUs to connect through the same PCIe switch. [community thread]

What should I do if my Dell R740 server is stuck on configuring memory during boot?

To resolve the issue, first drain the flea power by shutting down the server, disconnecting all power and network cables, and holding the power button for 20 seconds. After waiting for three minutes, reconnect the NIC and power cables, then wait an additional two minutes before turning the server back on. If the problem persists, try clearing the NVRAM by adjusting the jumper settings as indicated in the server's manual. [community thread]

How do I replace the HBA355i with the H745 RAID controller in a PowerEdge R6525?

Begin by performing a full backup, as the drive configurations may change when switching controllers. The cabling is generally the same, but it's advisable to verify specific configurations. The part number for the H745 RAID controller is JT47Y. [community thread]

What type of RAM is compatible with the PowerEdge R440?

The PowerEdge R440 supports specific DIMMs that are compatible with its 14th generation architecture. For a list of supported RAM modules, please refer to the official documentation or product page. [community thread]

How can I downgrade the X710 firmware on my R630 server?

Downgrading the X710 firmware on Dell R630 servers may be restricted due to OEM policies or BIOS settings. It is recommended to use Intel's NVM Update Tool with Secure Boot disabled, but be aware that the downgrade may still fail due to these limitations. [community thread]

What is the Dell part number for a CPU expansion module for the R940 server?

An expansion module is not necessary for the R940 server, as it supports only two CPUs mounted directly on the motherboard. All four CPUs are installed on the motherboard in other models. [community thread]

What should I check when an NVIDIA Tesla M10 throws a warning in R750 integrated diagnostics?

Start by reviewing the Lifecycle Controller logs (F10 at boot) for details on the warning, confirm System BIOS and iDRAC are current, and reseat the card — slot position and auxiliary power connections matter for the M10. If the warning persists after a reseat and firmware update, the card itself may need swapping to isolate hardware vs. configuration. [community thread]

What are the differences between the Poweredge R640 and the R640 XL?

The R640 and R640 XL are similar in many respects, but the R640 may have access to firmware updates that the OEM version does not. For more specific details, consult the documentation provided by the manufacturer. [community thread]

What should I do if my Dell PowerEdge R640 server won't start after a BIOS update failure?

Begin by reducing the server to its essential components: one CPU in socket 1, one memory module in socket A1, the right control panel with cable, one power supply, and the system board. Power on the server; if it successfully posts, gradually reintroduce the removed components to identify any faulty parts. If the issue persists, consider clearing the NVRAM or testing with a different motherboard. [community thread]

What should I do if I encounter a Riser 1 Fault on my refurbished R630 server?

The Riser 1 Fault may be due to an incorrect riser card installed in your server. Ensure you have the correct part numbers for the R630, such as 0YNF4C or 0999FX, as the part number 06K9W2 is intended for the R620. Contact support with your service tag for assistance in identifying the right component. [community thread]

How do I configure memory for a Dell PowerEdge R440 with dual CPUs?

For the Dell PowerEdge R440 with two CPUs, ensure that all memory modules are DDR4 and do not mix RDIMMs with LRDIMMs. Populate memory slots starting with the highest capacity modules in the white release tab slots, followed by lower capacity modules in the black release tab slots, and maintain identical configurations for both processors to avoid performance issues. [community thread]

How can I resolve the persistent battery missing alert on my PowerEdge R630 with a PERC H730p?

This alert is a normal indication of a missing Cache Protection Module (CPM) and cannot be permanently disabled. To address the issue, ensure the controller is properly seated and check the battery connections. Additionally, updating the PERC and iDRAC firmware may help with detection issues. [community thread]

How can I find the part number for a replacement hard drive caddy for a T440 server?

For the T440 server, you can use the following part numbers for hard drive caddies: WH5D2 for a 3.5-inch HDD, NTPP3 for a 2.5-inch SATA HDD, and 58CWC for a 3.5-inch SATA HDD. Additionally, the part number 9W8C4 is a bracket adapter that may also be useful. [community thread]

What are the correct configurations and part numbers for setting up NVMe and SAS drives in an R740XD server?

The R740XD's configuration for NVMe drives requires direct connections, and the specific drive slots for NVMe and SAS can vary based on the backplane used. For part numbers related to PCIe riser cards and cables, it's essential to refer to the official documentation or support, as modifications after purchase are not supported. [community thread]

What should I do if my PowerEdge R250 won't power on after adding components?

If your server shows no signs of power, indicated by blinking LEDs, it may be experiencing a 5V SW fault. Begin troubleshooting by disconnecting all USB devices, checking for shorts in the iDRAC Direct cable and video connections, and removing the front control panel cable. If the issue persists after these steps, consider testing with minimal components or replacing the motherboard. [community thread]

What CPUs are compatible with the Dell R440 server?

The Dell R440 server with the 4JN2K motherboard can support processors with a thermal design power (TDP) of up to 150 W, including the Xeon 6252, 6428, 6242, and 6240. For other motherboard versions, ensure the CPU has a TDP of less than 140 W for compatibility. [community thread]

What should I do if the DMI manufacturer and model information is missing from the iDRAC10 and operating system?

This issue may occur if the Lifecycle Controller detects incomplete initialization, limiting access to certain menus. If the server was purchased through the Dell OEM program, it may intentionally lack branding and DMI information. For resolution, consider contacting Dell support for assistance in restoring the generic branding. [community thread]

What can I do if my Intel X710 cards on C6420 servers won't upgrade past a certain firmware version?

To resolve firmware upgrade issues, consider performing a staged upgrade by first updating to version 22.5.x before moving to 23.0.x. Additionally, try running the updates from a Live ISO environment and ensure that the BIOS and iDRAC versions are consistent across all systems. [community thread]

Can I use a different server's heatsink on a PowerEdge T430 for better cooling?

It is not advisable to use heatsinks from other servers or third-party vendors due to potential compatibility issues and the need for proper thermal paste application. Instead, consider checking for airflow blockages and utilizing the fan speed offset feature to improve cooling performance. [community thread]

Will the NVIDIA RTX A4000 GPU function in a Dell PowerEdge T550 server?

The NVIDIA RTX A4000 has not been officially validated for use with the Dell PowerEdge T550, which means compatibility is uncertain. While it may work, there are no guarantees, and users are encouraged to seek experiences from others who may have tested this configuration. [community thread]

How can I set PXE as the primary boot device on a PowerEdge R7525 running in UEFI mode?

To set PXE as the first boot option, access the System BIOS Settings, navigate to Boot Settings, and then UEFI Boot Settings. You may need to disable other boot options to ensure that PXE remains the primary boot device, as changes to the UEFI boot sequence may not persist otherwise. [community thread]

What is the correct part number for the H740P Mini Mono card for the R6515 server?

The part number GP6RN is confirmed to be valid for both the R6515 and R6415 servers. [community thread]

Why is my second CPU not being detected in my R640 or R740 server?

Ensure that the memory configuration for both processors is identical and that the B side memory is populated. Additionally, verify that the BIOS and iDRAC firmware are updated, check for any bent pins in socket 2, and confirm that the heat sink and thermal paste are properly applied. [community thread]

Why can't I boot from the installed OS on my NVMe drives in the R640 server?

Ensure that the BIOS is set to the correct mode for the OS installation, either UEFI or Legacy. Additionally, verify that you are using supported NVMe SSDs, as not all drives may be compatible with the R640. [community thread]

Can I use a splitter for the PCIe power connectors on an R740xd to power both the backplanes and a GPU?

No, there is no official splitter available for the J_BP0 or J_BP2 connectors on the R740xd that would allow simultaneous power to both the backplanes and a PCIe GPU. Attempting to split these connections could lead to power delivery issues or damage to the components. [community thread]

Are the motherboard part numbers 4N3DF and 599V5 compatible for the R730 and R730xd servers?

The motherboards with part numbers 4N3DF and 599V5 are not compatible with each other. Each server model requires its specific motherboard part number for proper functionality. [community thread]

What should I do if I can't access the BIOS menu on my Dell PowerEdge R730xd?

If you're unable to enter the BIOS, try removing the RAID controller and see if that allows access. If it does, the issue may be related to the RAID disks or controller, so consider starting the server without the hard drives connected. [community thread]

What riser do I need to install a SAS9207-8e card in a PowerEdge R630?

To install a SAS9207-8e card in a PowerEdge R630, you will need to identify the correct riser part number based on your server's configuration. It is recommended to check the server's service tag for specific riser details. [community thread]

What should I do if my T630 server's iDRAC8 is not detected by the BIOS and shows a solid blue LED?

Start by performing an iDRAC reset to see if that resolves the issue. If the reset does not help, consider checking the TSR logs for further diagnostics. If problems persist, a motherboard replacement may be necessary. [community thread]

What is the maximum RAM capacity for the R630 server with LRDIMMs?

The R630 can support a maximum RAM capacity of 768GB with 32GB LRDIMMs and up to 3072GB with 128GB LRDIMMs, depending on the BIOS version and system configuration. To determine your server's current and maximum memory capacity, access the iDRAC interface and navigate to the Memory section. [community thread]

Why is the secondary PSU on my R730 becoming loud intermittently?

This issue may be related to the 'Hot Spare' feature, which can cause the secondary PSU's fan to ramp up and down. To troubleshoot, check for system event log warnings, ensure that the iDRAC BIOS and PSU firmware are current, and verify that the input power is within the specified range. If the problem persists, consider swapping the power supplies or connecting them directly to a wall outlet to rule out other factors. [community thread]

What NVMe expansion kits are compatible with the Dell PowerEdge R740XD server?

To expand NVMe storage on the R740XD, you need to ensure compatibility with the correct backplane. The complete part number for the backplane is K2Y8N 58D2W 0P1MJ3, but note that transitioning to NVMe may require replacing the PERC controller, as there is no conversion kit available. [community thread]

What should I do if my R630 server shows blinking DS0 and DS6 lights and won't power on?

If your R630 is not powering on and the DS0 and DS6 indicators are blinking, first ensure that all components, including RAM and expansion cards, are properly seated. If the issue persists, consider reseating or testing the CPUs, as they may be the source of the problem. [community thread]

What should I do if my Dell PowerEdge R740 server is stuck in a reboot loop after a BIOS update?

To resolve the reboot loop, try the following steps: first, check the iDRAC for a RollBack option to revert the BIOS. If that doesn't work, perform a power drain by shutting down the server, disconnecting all power and network cables, and holding the power button for 20 seconds. After waiting three minutes, reconnect the cables and power on the server, allowing two minutes for the system to initialize before turning it on. [community thread]

What should I do if my Dell PowerEdge R730 or R830 is stuck at the configuration memory screen?

To resolve this issue, ensure that the server has the minimum required components connected: the system board, one power supply, one CPU in socket CPU1, one memory module in socket A1, the left control panel, and one backplane card. If the problem persists after verifying these components, further troubleshooting may be necessary. [community thread]

Can I upgrade the RAID controller in a Dell PowerEdge R740 to a Dell PERC 12 H965i?

The Dell PERC 12 H965i is designed for newer server generations and may not be compatible with the R740, which is a 14th generation model. Additionally, the cable connections for the H965i may not fit the backplane of the R740, making this upgrade impractical. [community thread]

How can I resolve issues with Layer 1 connectivity on a PowerEdge C6620 using Dell SFP28 and Cisco SFP+ transceivers?

Ensure that the system firmware, including CPLD, BIOS, and iDRAC, is fully updated. You may also want to drain flea power by disconnecting all power and network cables, holding the power button for 20 seconds, and then waiting for 3 minutes before reconnecting. Additionally, check the BIOS settings to disable 1Gb options on the OCP NIC, leaving only 10Gb and 25Gb enabled. [community thread]

Do I need to update anything when upgrading the CPU in a Dell R430 server?

It is advisable to update both the BIOS and iDRAC firmware to ensure the server operates smoothly and maintains stability after the CPU upgrade. For detailed guidance on firmware versions, refer to the relevant support documentation. [community thread]

Is the 750W power supply from the Poweredge T430 compatible with the T340?

The 750W power supply from the T430 is not compatible with the T340. The T340 supports specific power supplies, including 350W and 495W options from different manufacturers. [community thread]

What motherboard revisions are compatible with the R730XD?

The R730XD does not have different revisions of systemboards, only varying part numbers. You can use any R730XD systemboard if the WCJNT revision is unavailable. [community thread]

Can I upgrade my R240 2Bay cold tray to a 4Bay configuration?

Upgrading from a 2Bay to a 4Bay cold tray is not possible after purchase, as these components are not designed for post-sale modifications. It's advisable to confirm specifications before making a purchase. [community thread]

What should I do if I can't access the iDRAC on my Dell PowerEdge R830 server?

If you're unable to log into the iDRAC, check for a default password on a pull-out tab located on the front control panel. Additionally, ensure that the service tag is registered in your name and consider clearing the NVRAM by adjusting the jumper settings as outlined in the server's documentation. If issues persist, verify the condition of the VGA port and try using different monitors and cables. [community thread]

Is the DELL 1.6TB NVME PCIE HHHL 0TWFTD compatible with the R730xd server?

Yes, the DELL 1.6TB NVME PCIE HHHL 0TWFTD is validated for use with the R730xd server. It can be purchased under part number DP/N: 91XH3. [community thread]

Why am I getting an unsupported memory configuration error after adding DIMMs to my Poweredge R650?

The error is likely due to an unbalanced memory channel configuration, which does not comply with Dell's memory population guidelines. To resolve this, ensure that each channel has an equal number of DIMMs and that the total count of DIMMs matches the supported configurations for your CPU. [community thread]

What parts are needed to install a 4 x 2.5" drive flex bay kit in a PowerEdge T630?

To install a 4 x 2.5" drive flex bay kit in a PowerEdge T630, you will need the drive cage and backplane assembly (DPN# WYNC0), a cable from the backplane to the bridge card (DPN# G3FGM), the bridge card itself (DPN# P31H2), and a signal cable (DPN# KV109). Ensure to consult the user guide for specific configuration details and limitations regarding RAID capabilities. [community thread]

How can I update the iDRAC firmware on a Dell R740 server using the RACADM tool?

To update the iDRAC firmware, first ensure the firmware image is stored on a TFTP or FTP server. Then, use the appropriate RACADM command to point to the firmware location on the server, specifying the iDRAC IP address, username, and password. [community thread]

What should I do if my PowerEdge R750xs server shows no POST?

First, remove all memory modules and check if the motherboard emits any beeping sounds. If there are no beeps, the motherboard may be faulty; if it beeps, test each memory module individually to identify any defective ones. [community thread]

What should I do if my PowerEdge R7525 is not completing BIOS updates or recovery?

Ensure that the service tag has been correctly imported to the new motherboard, as this is crucial for iDRAC to recognize the system. If you encounter errors like RAC0508, RED098, or RAC1236, they may indicate issues with BMC initialization, firmware compatibility, or internal errors during recovery. [community thread]

What should I do if I encounter memory errors after swapping CPUs in a Dell R640?

If you experience memory errors after a CPU swap, first try reseating the CPUs and removing power for at least 24 hours. If the issue persists, inspect the memory slot for any visible damage and consider testing with the original CPUs. If problems continue, it may indicate a motherboard issue. [community thread]

What should I do if my FC630 Blade won't power on after reseating a DIMM?

Begin by reseating the CMC module, as this action should not affect other blades and may restore access. If that fails, try connecting to the CMC via a terminal emulator with the appropriate settings. If access is regained, check the blade's status and logs; otherwise, power down the chassis to inspect the blade and ensure the DIMM is correctly seated. [community thread]

What should I do if my Dell PowerEdge T430 server displays voltage error messages?

To address voltage error messages, first simplify the server to its Minimum Hardware Configuration by removing all non-essential components, leaving only one CPU, one DIMM, and one power supply. If the errors persist after this step, it may indicate a failure in the system board, particularly in the voltage regulation or power distribution circuitry, which could require motherboard replacement. [community thread]

Why is my R360 server so loud even after adjusting the fan settings in iDRAC?

If your R360 server remains excessively loud despite configuring the fan settings to 'Minimum Power' and 'Off', it may indicate a deeper issue such as a faulty temperature sensor, a defective motherboard, or a firmware bug affecting thermal control. In such cases, professional support may be necessary to diagnose and resolve the problem. [community thread]

What should I do if my Dell R7615 server is stuck on the 'Please wait while the system is initializing' screen?

If your Dell R7615 server is stuck on this message, start by power cycling the server and checking all internal connections for security and damage. If the issue persists, access the iDRAC to review system logs and run diagnostics, and ensure the correct boot device is selected in the BIOS settings. [community thread]

What hardware is needed to convert a PowerEdge C6400 server to support an NVMe backplane?

To upgrade the C6400 to an NVMe backplane, you will need the NVMe backplane itself and specific backplane cables. Note that the C6400 can only support 8 NVMe drives, and if you have a PERC H330 or H730 installed in the C6420 nodes, you will need to replace them with a PERC S140 or HBA330, as the former do not support NVMe. [community thread]

What could cause an oscillating noise in a PowerEdge T440 server after a power supply replacement?

The oscillating noise may be due to a faulty power supply, even if it appears to be functioning. To accurately diagnose the issue, consider recording the sound and sharing it for further assistance. [community thread]

Is the NVIDIA Tesla M60 GPU compatible with the R770 CSP Edition server?

The NVIDIA Tesla M60 GPU is not supported on the R770 CSP Edition server. Currently, the only validated GPU for this model is the NVIDIA L4. [community thread]

How can I resolve compatibility issues with the X550 T4 NIC on my Dell R630 server?

The driver version 21.5.9 is not validated for the R630, so it's advisable to downgrade the NIC driver to a compatible version before installation. If you've already attempted an update, ensure to reboot the server to apply any changes, and consider power cycling the system to check if the iDRAC reflects the updated firmware. [community thread]

What should I do if I encounter a UEFI pre-boot error during a firmware upgrade on a PowerEdge R740xd?

If you see a UEFI pre-boot error, first ensure all hardware components are properly seated and connected. Try draining the flea power by shutting down the server, disconnecting all power and network cables, and holding the power button for 20 seconds. After waiting for three minutes, reconnect the cables and attempt the firmware upgrade again. If the issue persists, consider clearing the NVRAM and running diagnostics through the LifeCycle Controller. [community thread]

How can I remove a server that has been installed upside down in the rack?

To address a server that is installed upside down, first remove the side door of the rack to inspect the latch mechanism for any damage or bending. If the latch is obstructed, it may be necessary to contact technical support for further assistance, as removing the server could result in damage. [community thread]

Can I combine 128GB and 256GB Intel Optane RAM in the same server?

No, you cannot mix different capacities of Intel Optane persistent memory in the same system. Each server must have only one capacity of Optane RAM, and mixing operating modes is also not supported. [community thread]

Why is my Samsung 32GB 2Rx8 PC4 3200AA RAM not being recognized by my Dell PowerEdge R640 server?

If your server is not detecting the RAM, ensure that the memory modules are compatible with your system. It's advisable to check the server's specifications and possibly consult with the manufacturer for the correct part numbers or compatible memory options. [community thread]

What should I do if my EMC PowerEdge R7525 is stuck during BIOS loading?

First, perform a flea power drain by shutting down the server, disconnecting all power and network cables, and holding the power button for 20 seconds. After waiting for 3 minutes, reconnect the NIC and power cables, allowing 2 minutes for the system to initialize before powering on. If the issue persists, reduce the system to its minimum components required for POST and check for any faulty parts. [community thread]

Will the Samsung 990 Pro NVMe SSD work with the Dell Ultra 4x M.2 NVMe SSDs to x16 PCIe Adapter Card?

Yes, the Samsung 990 Pro NVMe SSD is compatible with the Dell Ultra-Speed adapter. However, to use multiple drives, ensure the adapter is installed in a PCIe x8 or x16 slot on a motherboard that supports bifurcation. [community thread]

Do I need to match CPUs when upgrading to dual processors in a T440 server?

Yes, both CPUs must be identical for proper functionality in a dual-processor configuration. Additionally, ensure that the memory is evenly distributed between the two CPUs, and keep your BIOS and iDRAC firmware updated for optimal compatibility. [community thread]

Is the RTX A4000 graphics card compatible with the PowerEdge T550 server?

The PowerEdge T550 server has not been officially validated for the RTX A4000 graphics card by Dell. While it may still function, there is no confirmation of compatibility, and users are encouraged to share their experiences. [community thread]

How can I download the latest BIOS for the PowerEdge R730?

If you're having trouble accessing the latest BIOS for the PowerEdge R730, it may be due to a temporary issue. You can download version 2.19 directly from the Dell support site at this link: https://dl.dell.com/FOLDER11275684M/1/BIOS_KM6P8_WN64_2.19.0.EXE. [community thread]

What should I do if my PowerEdge T440 freezes after installing a Radeon RX6600 graphics card?

The Radeon RX6600 is not officially certified for use with the PowerEdge T440, which may lead to stability issues. It is advisable to use a Dell-certified GPU for optimal performance and compatibility, as non-certified components can result in unpredictable behavior. [community thread]

What should I do if my Dell R640 server reboots frequently after upgrading CPUs?

First, ensure that the iDRAC firmware is updated to the latest version. Check for any bent pins in the CPU sockets and test each CPU individually by removing the second CPU and DIMMs, then running diagnostics to identify any issues. [community thread]

Why does the firmware update for Samsung SSDs in R740 servers fail with an invalid image file error?

Ensure that the server's BIOS, iDrac, and H730 RAID controller firmware are all updated to the latest versions, as outdated components may interfere with the SSD firmware update process. If the issue persists, consider reaching out to support for further assistance. [community thread]

What should I do if my Dell PowerEdge R760 displays a Fatal IO error?

This error indicates a malfunctioning component at bus 126 device 0 function 3. To pinpoint the issue, access the iDRAC interface, go to System > Hardware Inventory, and check the PCIe Devices section for details on the problematic component. Additionally, reviewing the iDRAC log may provide further insights into the device's status. [community thread]

Are Micron 7500 U.3 NVMe disks compatible with Dell R750 servers?

The Micron 7500 U.3 NVMe disks are not compatible with Dell R750 servers, which only support U.2 drives. Therefore, there is no firmware available for U.3 disks on this server model, and users should consult Micron for further assistance. [community thread]

What should I do if my Dell R740 server is stuck on loading BIOS drivers after a firmware update?

It is advisable to perform BIOS updates incrementally rather than making large jumps in version numbers. Check the iDRAC job queue for the BIOS upgrade status, and if it remains stalled, you can attempt to recover the BIOS using the RACADM command. If that fails, consider clearing the NVRAM as an alternative solution. [community thread]

Why is the 'OCP Slot Power During Host Off' setting missing from the iDRAC10 GUI on the R470 server?

The 'OCP Slot Power During Host Off' option is currently not visible in the iDRAC10 GUI, although it remains present in the SCP XML file. This issue may be addressed in future firmware updates, so it is advisable to submit a feature request through support for tracking. [community thread]

How can I identify genuine riser cards for the R730 server?

To verify authenticity, check for a Dell label on the riser card that includes the part number. Genuine riser cards usually come in professional packaging, which includes a box, instructions, and warranty information. [community thread]

Can I upgrade the CPU in my T430 server to an E5-2699 v4?

The T430 server does not support the E5-2699 v4 CPU. It is advisable to check for compatible processors, such as the E5-2698 v4, and ensure that your BIOS and iDRAC are updated before making any upgrades. [community thread]

Can the Dell PowerEdge R7725 server be configured with only one CPU and two RAM modules?

The PowerEdge R7725 server requires two processors, as it is designed for dual socket operation. Therefore, it is not possible to order it with just one CPU. [community thread]

What should I do if my Dell PowerEdge R740 is not booting and shows a critical RAID controller message?

If your server is not booting and displays a critical message related to the PERC, try powering off the server, removing all hard drives, and reseating the PERC card. If the issue persists, the PERC may need to be replaced. [community thread]

What should I do if my Dell PowerEdge R940 won't start and shows voltage errors?

First, ensure the chassis is securely closed, as an open chassis can prevent startup. Next, check that all power supplies are functioning and properly connected, and consider reseating CPU 4 and its RAM. If issues persist, inspect the motherboard for damage and test power supply voltages. [community thread]

What network cards are compatible with the R440 LOM slot?

The R440 LOM slot supports several Dell-branded network cards. Compatible options include the dual-port 1GbE cards (0N7HDF and 04GJJR), quad-port 1GbE cards (0N7HDV and 0N7HDW), and dual-port 10GbE cards (0N7HDP and 0N7HDN). [community thread]

What backplane is needed to add NVMe support to a Dell R740XD2 server?

To enable NVMe functionality on the Dell R740XD2, you will need the backplane with part number PC8TD, which supports 24 NVMe drives or a combination of SATA and NVMe. Ensure to consult the user guide for proper cabling instructions, as the hardware configurations for R740XD and R740XD2 differ. [community thread]

Can I install two NVIDIA A100 GPUs in NVLINK on a Dell PowerEdge R740 server?

Yes, the Dell PowerEdge R740 supports the installation of two NVIDIA A100 GPUs linked via NVLINK. For detailed specifications and compatibility, refer to the official data sheets and related resources. [community thread]

How can I transfer the iDRAC license from a malfunctioning Dell R740 motherboard?

To transfer the iDRAC license from a defective motherboard, you will need to contact Dell Technical Support for assistance. They can help you retrieve the license associated with your original motherboard. [community thread]

What are the part numbers for the PCIe risers in the Power Edge R6515?

The R6515 uses two different PCIe risers: the left riser is part number 6KKNH and the right riser is part number W53WP. For additional purchasing information, please reach out to a sales representative or authorized reseller. [community thread]

What rail and cable management kit is compatible with the R330 server?

For the R330 server, you can use the ReadyRails 1U Static Rails (SKU: 770-BBIC) or the ReadyRails Sliding Rails without a cable management arm (SKU: 770-BBJS). Additionally, a 1U Cable Management Arm (SKU: 770-BBIE) is available for cable organization. [community thread]

How can I remove UEFI boot order entries on a PowerEdge R750 server?

To delete UEFI boot entries, access the UEFI Boot Manager by pressing <F11> during startup. From there, you can select the option to delete existing boot options. [community thread]

What power cable configuration is needed to install an NVidia A30 GPU in an R730 server?

The R730 does not officially support the NVidia A30, but users have successfully operated similar GPUs by creating custom power cables. It is advisable to use a Y-cable that connects power from both PCI risers to the GPU to ensure adequate power supply. [community thread]

Can the Dell PowerEdge T150 be directly connected to UK mains power?

The Dell PowerEdge T150 features a universal auto-sensing power supply that accommodates input voltages from 100 to 240V AC, making it compatible with the UK mains power of 230V at 50Hz. However, you will need a UK-compatible power cable or a plug adapter for the US power cable. [community thread]

Why is the gateway not being saved on my R6725 iDRAC when using DHCP?

To troubleshoot the issue, first verify if the gateway is being received by using the command 'racadm getniccfg'. If it is missing, attempt a reboot with 'racadm racreset'. If the problem persists, consider resetting to factory defaults with 'racadm racresetcfg', keeping in mind that this will erase your current settings. [community thread]

Where can I find the NUMA layout diagram for the PowerEdge R640 motherboard?

Currently, there is no comprehensive architectural block diagram available for the NUMA nodes of the PowerEdge R640. The only diagram that exists may be limited in detail. [community thread]

Why won't my R550 server power on with the DELL BOSS-2 installed?

Ensure that both power and signal cables are properly connected to the BOSS-2 controller. Additionally, inspect the connectors for any bent or loose pins, and verify that the riser slots are not pinching the power cable. [community thread]

How can I add a new SATA hard disk to my Dell PowerEdge T440 server?

You have two main options for adding the new SATA hard disk: integrate it into the existing RAID-1 array or create a new virtual disk. If you choose to add it to the RAID-1, you will need to bring the disk online and consider converting to RAID-5 or RAID-10, as RAID-1 requires an even number of disks. Alternatively, you can keep the existing RAID-1 intact and set up the new disk as a separate virtual disk for additional storage. [community thread]

Can I set up an R740XD with a dual controller MPIO array and a separate controller for additional drives?

While the R740XD chassis can support dual controllers for a 24-bay MPIO array, there is no confirmed documentation indicating that this specific configuration is feasible. The compatibility of MPIO also depends on the operating system and storage subsystem in use, so further testing or user experiences may be needed to verify this setup. [community thread]

Why can't I find the firmware update list for my 17th Gen server in the Lifecycle Controller?

Firmware updates for 17th Gen servers are no longer available through the Lifecycle Controller. You can update firmware using iDRAC, where you can upload multiple files for updates, though a reboot may be necessary for changes to take effect. [community thread]

Can I use BIOS version 2.25.0 with iDRAC version 5.00.00.00 on a Dell R740 server?

No, you must upgrade iDRAC to at least version 6.00.00.00 before using BIOS version 2.25.0. It is advisable to update iDRAC first, followed by the BIOS, and ensure to back up your server configuration beforehand. [community thread]

How can I resolve the issue of my 2Rx4 memory being detected as Quad Rank?

To address this issue, ensure that your DIMMs are properly populated according to the server's memory guidelines. Check the BIOS version and verify the specifications of the installed DIMMs, as only certain capacities are supported for 2R DIMMs. [community thread]

Why is my Dell PowerEdge R350 server showing 'No memory found' after adding new RAM?

Ensure that all installed DIMMs are DDR4 and compatible with the server. Check that the memory modules are correctly seated and that a processor is installed, as memory sockets can only be populated in this case. For detailed installation guidelines, refer to the official documentation. [community thread]

What is the best dual CPU configuration for a Dell PowerEdge T430?

For optimal performance, it is recommended to use CPUs that are listed in the parts database for the T430. The Xeon E5-2620 v3 is confirmed to work in dual mode, while the E5-2696 v3 and E5-2699 v3 are not supported for dual configurations. [community thread]

What should I do if my Dell PowerEdge T340 server fails to POST and shows an amber blinking LED?

To troubleshoot a no-POST issue, start by powering down the server and disconnecting all components except for the processor, one memory module in socket A1, and one power supply. After waiting for two minutes, reconnect the power and attempt to power on the server. If it still does not POST, the problem may lie with one of the remaining components, such as the motherboard or power supply. [community thread]

What should I do if I encounter a memory initialization error on my R760 server?

If you receive a memory initialization error, first try replacing the DIMM in the specified slot, as it may be faulty. Additionally, you can test the memory by swapping it with another slot to determine if the issue lies with the memory module or the slot itself. [community thread]

What is the recommended heatsink for a R440 server with a 150W TDP CPU?

For the R440 server with a 150W TDP CPU, the recommended heatsinks are part numbers 1CW2J for CPU2 and 994RT for CPU1. It's advisable to verify compatibility with your specific configuration before making a purchase. [community thread]

Can I use both SAS and NVMe drives in an R640 server configuration?

The R640 supports a mixed configuration, but the last four slots are designated solely for NVMe drives, meaning SAS drives cannot be installed there. Additionally, there is no hardware NVMe RAID available for this server generation. [community thread]

How can I convert an R750 server into a vSAN ESA ReadyNode?

To convert an R750 into a vSAN ESA ReadyNode, it is recommended to use an HBA355. However, be aware that changes to the storage configuration after purchase are not supported, and there are no kits available for modifications. [community thread]

Where can I find part numbers for NVME backplane cables for an R960 server?

You can find the part numbers for NVME backplane cables by visiting the provided link: https://dell.to/3UlFMBW. [community thread]

What type of heat sink is needed for an Intel Xeon Gold 6134 processor in an R640 server?

For the Intel Xeon Gold 6134, a standard heat sink rated for up to 165W, such as part number 0F8NV, is suitable. The C6R9H heat sink, which supports up to 125W, may not be adequate for optimal performance. [community thread]

What should I do if I encounter a PR21 error while creating a virtual disk on a Dell R730 server?

Check the Lifecycle Log for more details on the failure. Ensure that the drives are validated by Dell, and consider removing certain drives to see if that allows the virtual disk creation to succeed. Alternatively, try creating the virtual disk using the PERC BIOS during the server's POST instead of using iDRAC. [community thread]

Can I set up NVMe hardware RAID on an R640 server?

The R640 server only supports NVMe RAID through the embedded S140 controller, which operates as a software RAID. For hardware RAID, you would need to use a 15th Gen server with an H755n controller, as the R640 does not support this feature. [community thread]

Why is my RAM not being recognized in my PowerEdge R740?

The issue may stem from compatibility between the RAM modules and the server. Ensure that your server's firmware is fully updated, as this can sometimes resolve recognition problems. [community thread]

What should I do if my Ubuntu OS installation via NFS on iDRAC 10 fails frequently?

To resolve installation failures, first ensure that both iDRAC and BIOS are updated to the latest versions. For better results, try installing on a single host before scaling up, and consider using a dedicated HTTP server for ISO delivery instead of co-hosting with NFS. As a temporary solution, using PXE/iPXE or local media for installations may help avoid issues during batch provisioning. [community thread]

How can I resolve a power cap issue on my C4140 with V100 GPUs?

Ensure that your system's BIOS and iDRAC firmware are updated to the latest versions. If the issue persists, try swapping the GPU with another one to determine if the problem is related to the GPU itself or the slot. Additionally, confirm that the NVLink Air Shroud is correctly installed and that the heatsink is properly secured. [community thread]

What should I do if my R640 iDRAC9 is intermittently unresponsive to SNMP/HTTPS requests?

Check for potential IP conflicts, as another device may be using the same iDRAC IP address. If conflicts are not the issue, consider downgrading the iDRAC firmware to a previous version or adjusting the query intervals of any third-party monitoring tools. [community thread]

How can I reduce the power consumption of my PowerEdge T430 server?

To minimize energy usage, consider switching to SSDs if you're currently using traditional spinning disks, as they consume less power. Additionally, remove any unused expansion cards and disable power-hungry features like C1E and C State if they are not necessary for your operations. [community thread]

What should I do if my server is stuck after a BIOS update following a RAM upgrade?

Check the status in the IDRAC interface to diagnose the issue. Additionally, test the server's functionality without the upgraded RAM to determine if the new memory is causing the problem. [community thread]

What is the pinout configuration for the T430 PSU GPU connector when installing a Tesla V100 GPU?

The T430 PSU GPU connector pinout shows that pins 1-3 provide +12V, pin 4 is GROUND, pins 5-6 are GROUND, pin 7 outputs 3.3V, and pin 8 is GROUND. It's important to ensure compatibility and to create a custom cable if necessary, as pre-made options may not have the correct pinout. [community thread]

Why is the PERC H730p not being detected on my PowerEdge R640?

Ensure that the PERC H730p is properly seated and that all connections are secure. Check the BIOS settings to confirm the Boot Mode is set to either BIOS or UEFI, as this affects access to the controller configuration. If the issue persists after verifying these steps, the controller may be faulty. [community thread]

How do I configure the backplane for a Dell R730xd with multiple controllers?

To set up the backplane for your R730xd with both the H730P and HBA330 controllers, refer to the Dell PowerEdge R730xd Owner's Manual for cabling diagrams and configuration guidance. You may need to experiment with the connections to determine the optimal configuration for your needs, as the setup can be complex. [community thread]

What transceivers are compatible with the Broadcom 57412 Dual Port 10Gb, SFP+, PCIe Adapter for Dell servers?

Compatibility of transceivers with the Broadcom 57412 adapter may vary, and it's recommended to consult with sales support or check with authorized resellers for specific part numbers. The SFP+ part number C5RNH has been noted for the R960 model, but confirming compatibility before purchase is advisable. [community thread]

What should I do if I encounter UEFI0375 or UEFI0351 errors after replacing NVDIMMs in an R940 server?

To resolve UEFI0375 or UEFI0351 errors, ensure that the NVDIMMs are installed in the correct CPU slots. Then, access the System BIOS, navigate to Memory Settings, and configure the Persistent Memory by setting the Persistent Memory Mode to 100% Persistent. Save the changes and reboot the server. [community thread]

Why doesn't the Poweredge T440 support Resizable BAR in the BIOS?

The Poweredge T440 is designed for general business applications rather than high-performance graphics tasks, which is why it lacks support for Resizable BAR. This feature is more relevant for gaming and graphics-intensive workloads, while the T440 is optimized for server functions like virtualization and database management. [community thread]

Where can I find the pinout for the GPU power connectors on a PowerEdge XR12 and the part number for the necessary cables?

The pinout information for the GPU power connectors on the PowerEdge XR12 can typically be found in the system's service manual. For specific cable part numbers, including fanout options, refer to the official documentation or support resources. [community thread]

Can I install an NVIDIA A100 GPU in a Dell R740 server?

The NVIDIA A100 80G is certified for the R750, but there is no confirmation for compatibility with the R740. Currently, only the A100 40G is validated for use with the R740xd. [community thread]

What should I do if my Dell PowerEdge R940 shows a BP0 PG voltage error and won't start?

To address the BP0 PG voltage error, you need to update the CPLD to version 1.0.5 via iDRAC. However, if the server does not power on, you may need to troubleshoot further or seek professional assistance. [community thread]

Why does my server shut down after losing one power supply when it shouldn't?

The unexpected shutdown may be due to outdated firmware or misconfigured settings. Ensure that all firmware, including BIOS and iDRAC, is updated to the latest version, and verify your power management settings. Running hardware diagnostics can also help identify any underlying issues. [community thread]

Will the R740 server support the Mellanox MCX416A-CCAT 100G card?

The R740 server is compatible with PCIe 3.0 x16 interfaces, which suggests that the Mellanox MCX416A-CCAT card may work. However, since this specific card is not verified with Dell's part number, compatibility cannot be guaranteed, and using a non-Dell version might lead to increased fan noise. [community thread]

Why are NVMe drives not showing up in the operating system on a R740xd server?

Ensure that the NVMe drives are properly initialized in the operating system settings, as they may not appear in Disk Management until this step is completed. Additionally, verify the configuration of the PCIe extender card and the slots used, as well as the compatibility of the H740P controller with NVMe drives. [community thread]

Does the PowerEdge R7525 support Resizable BAR?

To enable Resizable BAR on the PowerEdge R7525, check the BIOS settings for options related to memory addressing, such as 'Above 4G Decoding' or 'Resizable BAR'. If these options are not visible, ensure that your BIOS is updated to the latest version. [community thread]

What should I do if my Dell PowerEdge T430 server is not recognizing an installed HDD?

If your Dell PowerEdge T430 is not detecting a hard drive, first ensure that the drive is properly seated and check all connections. You can also try moving the drive to a different slot to see if the issue persists. If the drive remains undetected, it may be failing, and running the built-in hardware diagnostics through the LifeCycle controller can help identify any errors. [community thread]

What are the requirements for using a SATA/SAS/NVMe backplane with a PowerEdge C6400 and C6525 motherboard?

To successfully use a SATA/SAS/NVMe backplane with the PowerEdge C6400 and C6525, ensure that the motherboard supports dual SNAP I/O connections, as this is necessary for NVMe functionality. Check the cabling and hardware against the provided diagrams, and consider using part number 75F10 for the linking board to NVMe connection. [community thread]

Is the Dell firmware version 8.11.2.0.18-26 compatible with the PERC H965i Front RAID controller?

If the firmware is listed as compatible, it should work with the PERC H965i Front RAID controller. However, be aware that installation on unsupported servers may be challenging. [community thread]

Why are my 15.36TB Micron NVMe 9300 Pro drives not appearing in iDRAC on my Dell R750?

The 15.36TB Micron NVMe 9300 Pro drives are classified as Datacenter Scalable Solutions (DSS) and may not be visible in iDRAC as intended. To view these drives, consider using Dell OpenManage Server Administrator (OMSA) for better compatibility. [community thread]

What should I do if my R640 iDRAC is stuck on INITIALIZING after a firmware update?

To resolve the iDRAC initialization issue, perform a flea power drain by shutting down the server, disconnecting all power and network cables, and holding the power button for 20 seconds. After waiting for three minutes, reconnect the NIC and power cables, allowing two minutes before turning the server back on. If the problem persists, consider clearing the NVRAM by adjusting the jumper settings as indicated in the server documentation. [community thread]

Why is my PowerEdge T330 server not detecting the embedded NICs?

If the embedded NICs are not recognized by the operating system, it may indicate a hardware issue, particularly with the motherboard. Ensure that the NICs are enabled in the BIOS and check if they are visible in the iDRAC system inventory. If they are not detected by iDRAC, it is likely that the NICs are malfunctioning. [community thread]

What is the recommended BIOS upgrade path for the Dell PowerEdge R730?

To upgrade the BIOS from version 2.5.5 to 2.19.0, first update to BIOS version 2.10.5 and iDRAC version 2.70.70.70, then proceed to BIOS version 2.19.0 and iDRAC version 2.86.86.86. [community thread]

What should I do if my R740 server fails to POST?

If your R740 server does not POST even with a minimal configuration, it may indicate a hardware issue, likely with the motherboard. Ensure you have one CPU in socket 1 and one DIMM in socket A1, and consider testing different components or replacing the system board if voltage errors persist. [community thread]

What is the part number for the riser card compatible with the R660 server for a full height SAS card?

The appropriate riser card for the R660 server that supports a full height SAS card is part number 540-BFFR. This riser configuration includes 2x16 FH slots and is designed for customer installation. [community thread]

How can I replace the DVD drive in a PowerEdge T430 with a 2.5" drive?

Dell does not provide a direct 5.25" to 2.5" hard drive carrier for the PowerEdge T430. You can obtain a blank drive bay kit or a specific ODD blank part (P9C4X) by contacting the sales department for availability and purchasing options. [community thread]

What should I do if my R760xs server shows an error about authenticating the FPGA or CPLD?

This issue may be resolved by performing a cold reboot of the server. If the problem persists, it is advisable to check the TSR logs for further insights or to contact support for assistance. [community thread]

Will sending a test alert for high or critical temperature via iDRAC cause my server to shut down?

No, sending a test alert (TMP0102 or TMP0103) through iDRAC does not trigger an automatic shutdown. These alerts are designed to simulate conditions for monitoring purposes and do not initiate hardware management actions like shutting down the server. [community thread]

How can I disable Intel DCI on Dell R740 or R640 servers running Redhat 8?

Intel DCI cannot be turned off on Dell R740 and R640 servers as the BIOS does not provide options for Direct Connect Interface controls. For security, it's advisable to disable any unused ports such as USB and iDRAC direct. If you have concerns regarding CVE advisories, consider consulting the relevant security documentation or contacting your software vendor. [community thread]

What should I do if I encounter a PCIe error when installing a Tesla A2 in a Dell PowerEdge R640?

The PCIe error may be due to compatibility issues, as the Tesla A2 is not listed as supported for the R640 or XC640 models. It's advisable to check the part number of the GPU for compatibility with your server, as only certain models like the Tesla T4 or NVIDIA Quadro NVS 310 are confirmed to work. [community thread]

How can I configure 64GB or 96GB DIMMs for the R6715 or R7715 servers when the sales tool only allows 32GB DIMMs?

It appears that the sales tool may have limitations preventing the selection of larger DIMMs. For assistance, it's recommended to contact the sales team directly with your requirements, as they can provide options and a quote based on your needs. [community thread]

How can I find the PCIe specifications for the R760 server?

You can refer to the PCIe specifications for the R760 server on the manufacturer's website, specifically on page 3 of the provided link. Unfortunately, detailed block diagrams are not available. [community thread]

Why does the DSU fail to update the DPU firmware on PowerEdge R7625 and R6615?

The failure to update the DPU firmware is likely due to an issue with the update catalog, which incorrectly identifies the package as applicable to your system. This problem should be resolved in the next catalog release, so ensure you are using the latest version. [community thread]

Can I connect a Tesla P100 GPU to an R740 server without the proper riser?

Connecting a Tesla P100 GPU to an R740 server requires a complete installation kit, including the appropriate riser with power connectors. It is recommended to consult the official documentation or contact sales for the necessary components. [community thread]

What does the RED007 error mean when updating SAS-RAID on a PowerEdge R730?

The RED007 error indicates that the system cannot verify the digital signature of the SAS-RAID update package, which is a security measure to ensure the update's integrity. To resolve this, check the operating system, the specific update being attempted, and ensure that other components like BIOS and iDrac are also up to date. [community thread]

Can NVMe SSDs be used in the PowerEdge R360 server with the H755 storage controller?

The R360 server does not officially support NVMe SSDs with the H755 controller, as the only validated NVMe option is the BOSS-N1, which is a specific configuration. The server primarily supports 2.5-inch and 3.5-inch SAS and SATA drives. [community thread]

Is there an air shroud required when using NGC09 coolers in the R730XD server?

No air shroud is needed when using the 165W heatsink with the R730XD. The only available air shroud is designed for lower power processors. [community thread]

How can I add more drives to my Dell T430 or T440 servers if there is no front space available?

The Dell T430 and T440 servers have fixed backplane configurations that cannot be changed after purchase, limiting the number of drives you can add. If you have the x8 SAS/SATA backplane, you cannot add more drives; however, you could consider upgrading to larger capacity drives and creating a new array. [community thread]

What should I do if I receive a write endurance alert for my SSD in an R640 server?

You can replace the SSDs one at a time, allowing the RAID 1 configuration to maintain data redundancy during the process. When selecting new SSDs, consider their write endurance, capacity, compatibility with your server, and overall reliability. [community thread]

Why do identical R450 servers show different IPMI sensor readings?

Discrepancies in IPMI sensor data among identical R450 servers can occur due to variations in the tools used for monitoring. Using a more reliable command-line tool like 'ipmitool' may provide consistent and comprehensive sensor information across all servers. [community thread]

Why is the system status image missing after updating iDRAC9 on my R7525 server?

The absence of the system status image is due to missing graphics for NVMe drives in iDRAC versions 7.x. This issue has been acknowledged and is expected to be resolved in a future iDRAC update. [community thread]

Is it safe to rollback the iDRAC firmware on a T640 from version 6.10.30.20 to 3.21.21.21?

Rolling back directly to version 3.21.21.21 from 6.10.30.20 is not recommended due to compatibility issues. It is advisable to downgrade incrementally through several intermediate versions to ensure stability. [community thread]

Why does the OS Driver Pack RMG6P 25.08.04 show as applicable for the PowerEdge R650 when it is not compatible?

The OS Driver Pack RMG6P 25.08.04 is incorrectly listed as applicable for the PowerEdge R650 in the DSU catalog, despite not being supported for this system. This issue is recognized, and efforts are underway to correct the catalog to prevent this update from being offered for the R650. [community thread]

Why can't I see or use the SD cards in my T430 server after installing a dual SD card model?

The SD cards may not be recognized due to compatibility issues, especially if they are not from a supported brand. Ensure that the SD cards meet the necessary specifications and check the server's documentation for any required configurations. [community thread]

What should I do if my Dell R7615-XL server is not booting and shows an amber LED light?

First, ensure that the server's firmware is updated to the latest versions for BIOS and iDRAC. Then, simplify the configuration by removing all components except for one CPU, one memory module in slot A1, and one power supply, and attempt to power on the server. If it still does not boot, consider reseating any modular cables and swapping power supplies between slots to identify the issue. [community thread]

What should I do if my R440 server shows a CPU 2 machine check error?

First, ensure that the server has completed POST and check if any hardware changes were made recently. Perform a flea power drain by shutting down the server, disconnecting all power and network cables, and holding the power button for 20 seconds. After waiting for three minutes, reconnect the cables and power on the server, allowing two minutes for the system to initialize before turning it on. [community thread]

Can I configure an R750xd with both SSD SAS and NVMe drives?

Yes, the H755 controller supports both SSD SAS and NVMe drives, while the H755N is specifically for NVMe only. Ensure that your configuration aligns with the capabilities of the chosen controller. [community thread]

Can I upgrade the TPM firmware from 1.2 to 2.0 on a PowerEdge T330 server?

No, it is not possible to upgrade the firmware of a TPM 1.2 chip to 2.0. The TPM 2.0 firmware is specifically designed for the TPM 2.0 chip. [community thread]

Why is my PowerEdge R740xd showing a HWC2003 error related to the NVMe backplane connection?

The HWC2003 error is likely due to the use of a non-Dell SFF-8654 cable, which may not support necessary sideband signaling. To resolve this, consider using a Dell-branded cable designed for the R740xd to ensure proper connectivity and signaling. [community thread]

What does a flashing amber LED on the motherboard of a T340 indicate?

A flashing amber LED typically signals a hardware issue. Ensure that your server meets the minimum configuration for POST, which includes a processor, one memory module in socket A1, and one power supply unit. If the problem persists, consider checking the iDRAC or raising a support ticket for further assistance. [community thread]

What are the part numbers for replacement fans on a Dell PowerEdge R640 server?

The acceptable part numbers for replacement fans on a Dell PowerEdge R640 server are KG52T for the high-performance fan and RG2X2 for the standard fan. You can also check the current fan part numbers installed in your server. [community thread]

Why isn't my PowerEdge T440 recognizing my installed graphics card?

The PowerEdge T440 is not compatible with additional graphics cards due to its design limitations. If you're experiencing issues with the integrated graphics, consider troubleshooting those or replacing the server if a dedicated GPU is necessary. [community thread]

What should I do if my T430 won't power on after a CPU upgrade?

If your T430 fails to power on after upgrading the CPU, try resetting the system by removing all components except for the essential ones, including the system board, one power supply, and a single DIMM in socket A1. Additionally, remove the CMOS battery for about 30 seconds and hold the power button for 15 seconds without power before reconnecting and attempting to power on the server again. [community thread]

What caddy or tray is needed for a Samsung PM9A3 2.5" 3.84TB NVMe U.2 SSD in a Dell R760XS server?

To install the Samsung PM9A3 SSD in a Dell R760XS server, you will need the following parts: 1x DXD9H (caddy for 2.5" drive), 4x HFX4T (screws), and 1x P7G03 (SSD itself). It is advisable to confirm with sales for any integrated part options. [community thread]

Is the BOSS-S2 compatible with the Dell R640 server?

The BOSS-S2 is not listed as compatible with the Dell R640; only the BOSS-S1 is supported. For detailed compatibility information, refer to the technical guide and user manuals provided by Dell. [community thread]

Why won't my PowerEdge R540 boot from an NVMe drive?

Ensure that your BIOS, iDRAC, and PERC firmware are updated, and check that secure boot is disabled. Set the BIOS to prioritize booting from the NVMe drive before other devices, and save the changes. If issues persist, consider using a compatible BOSS card with your NVMe SSD. [community thread]

Why is my 99GTM NDC Quad-port showing 6 ports in iDRAC instead of 4?

The issue may arise from compatibility, as the 99GTM NDC is not officially supported in 14th generation servers like the R640, which could lead to incorrect port detection. Testing the NDC in a compatible 13th generation server may provide clarity on its functionality. [community thread]

What should I do if the NIC on my PowerEdge R760 servers keeps failing?

If you are experiencing recurring issues with the Integrated BCM57416 NetXtreme-E Dual-Media 10G RDMA Ethernet Controller, it is advisable to open a support ticket for assistance. Ensure to request an escalation for a more permanent solution, especially if the problem persists despite previous repairs. [community thread]

Is the BOSS-N1 controller compatible with the PowerEdge T160 server?

Yes, the PowerEdge T160 is compatible with the BOSS-N1 controller. It is a monolithic controller that connects directly to the mainboard rather than through a PCIe slot. Ensure you use the correct components and supported M.2 drives as specified in the user guide. [community thread]

Can I use a second PCIe card in an R650xs with only one CPU installed?

No, to utilize a second PCIe card in slot 3 via riser 2, a second CPU is necessary. Without the second CPU, slot 3 will not function, and you will only have access to slot 1. [community thread]

Can I use the same heatsink for the second CPU in a Dell PowerEdge R540?

For the second CPU in a Dell PowerEdge R540, you will need a specific heatsink part number 401-ABHI, which includes both the fan and heatsink components. It's advisable to check your server's fan configuration to ensure proper cooling and prevent overheating. [community thread]

Can I use 2RX4 DIMMs instead of 2RX8 DIMMs in an R730 server configuration?

Yes, 2RX4 DIMMs are compatible with the R730, and they may provide slightly improved performance in specific workloads due to their design. However, the performance difference is often minimal and may not be significant in all use cases. [community thread]

How can I disable the integrated NIC on a PowerEdge R730xd while still accessing iDRAC with a new NIC?

The R730xd features a dedicated iDRAC port that has its own MAC address, allowing you to use either the integrated NIC or a slotted NIC without affecting iDRAC functionality. If the iDRAC is connected to its dedicated port, changes to the other NICs will not impact iDRAC access. [community thread]

Is the Dell PCIe x16 NVMe adapter P/N: 80G5N compatible with the Poweredge T440?

The Dell PCIe x16 NVMe adapter P/N: 80G5N is primarily designed for workstation models and may not be compatible with the Poweredge T440. For accurate compatibility information, it is advisable to consult with the retailer or manufacturer directly. [community thread]

What is the part number for the cable connecting CTRL_SRC_SB1 to BP_DST_SB1 and RBP_B in a R750xs server?

The required part numbers are WTHHV for the 12x3.5-inch SAS/SATA cable assembly and R4C4X for the micro cable assembly. It's advisable to verify these numbers against the documentation to ensure accuracy. [community thread]

How can I resolve the UEFI0097 error when adding memory to an M630 server?

To fix the UEFI0097 error, access the BIOS setup by pressing F2 during boot and change the Memory Operating Mode to 'Optimizer Mode,' which is the default setting. Ensure that the memory configuration meets the server's requirements. [community thread]

How can I bypass the PERC H730 on a Dell R640 server?

To bypass the PERC H730 on a Dell R640, you may need to use cable part number 9G3T5. However, it's advisable to consult with sales for confirmation, as additional components like the backplane may also need to be changed. [community thread]

How can I safely remove failed hard drives from a PowerEdge R7525 server?

To remove the failed hard drives, you will need to power down the server using the physical power button, as exiting the Device Health Manager may not be possible. If you have not configured iDRAC, the power button is your only option. After shutting down, replace the drives with compatible ones, and if data recovery is necessary, consider contacting a professional data recovery service. [community thread]

How do I add more RAM to my R730xd server?

The R730xd supports various DIMMs from 4GB to 64GB, so you can choose based on your needs. For purchasing, contact Spare Parts at 1-800-372-3355, and refer to the memory population guidelines in the server documentation for installation instructions. [community thread]

What riser options and NVMe support are available for the Dell R440 with a single CPU?

The R440 can utilize the right riser (0RHWXM + 0MC2DD) in a single CPU setup, but only the slots connected to CPU1 will be active. For NVMe support, the R440 can accommodate up to four PM1725a drives, provided the correct backplane and cabling are used, with two add-in cards also fitting within the PCIe slot limitations. [community thread]

What should I do if my R630 iDRAC keeps rebooting after a firmware update?

If the iDRAC is rebooting frequently, it may indicate memory corruption. Try disabling the Lifecycle Controller in the iDRAC settings, then power cycle the server. If issues persist, consider using the NVRAM clear jumper or contacting support for further assistance. [community thread]

Why is my Dell R630 only detecting one of the four new memory modules I installed?

If your memory modules are compatible but only one is recognized, try reseating them to ensure they are properly installed. Test each module in different slots to check for faulty slots, and inspect for any physical damage or debris. Additionally, consider updating the BIOS/UEFI, as this may resolve detection issues. [community thread]

What should I do if my DELL R730 server is experiencing a purple screen of death related to network components?

To address the purple screen issue, verify if the Intel I350 Gigabit Network card is installed by using the command 'lspci | grep -i intel' to check the bus ID. You can troubleshoot further by either removing the network card to see if the problem persists or replacing it with a spare unit. [community thread]

What is the power consumption of a Dell PowerEdge R6625 with 2 PDUs rated at 1.8W?

For detailed power consumption specifications of the Dell PowerEdge R6625, please refer to the PSU specifications found on page 28 of the provided documentation. [community thread]

Can I use different sizes of RAM in the PowerEdge R450?

Yes, it is possible to mix different RAM sizes in the PowerEdge R450, provided that all modules are of the same type, specifically Registered DIMMs (RDIMMs). For optimal performance, it's recommended to arrange the RAM modules evenly across the channels and ensure they operate at the same speed. [community thread]

What should I do if my PowerEdge T340 shows correctable memory errors for DIMM_A4?

If your PowerEdge T340 is indicating correctable memory errors for DIMM_A4, consider replacing the DIMM if the errors persist after performing a memory drain and swapping the DIMM to another slot. The server's BIOS includes self-healing features, but ongoing errors may require hardware replacement. [community thread]

What RTX GPUs are compatible with the R740 server?

For the R740 server, the compatible RTX GPUs from the 6000 series and above include the RTX6000 passive (part # 263NN) and the RTX8000 (part # 10K7M). Note that there is no XL version of the R740; only the R720 and R730 have XL variants. [community thread]

What should I do if both the CMOS and DRAC batteries in my Dell R440 are reported as bad intermittently?

The CMOS battery can fail, but the iDRAC does not have a battery. If you are experiencing issues with the RAID controller battery, it may impact the operating system boot process. Consider checking the specific error messages for further diagnosis. [community thread]

What is the front grill of the R930 server called and what does it look like?

The front grill of the Dell PowerEdge R930 is commonly known as the 'bezel.' In your model, it features an opening for four drive bays on the left side, while the remainder is solid. Bezel designs can differ based on the server's configuration and may be removable or replaceable. [community thread]

What does the CPU0000 CPI1 Internal Error (IERR) mean on my R730 server and how can I resolve it?

The CPU0000 CPI1 Internal Error (IERR) typically indicates a system error detected by the CPU rather than a direct CPU fault. This may stem from issues like firmware mismatches or system interrupts. To troubleshoot, perform a minimal POST by using only essential components and gradually reconnect other parts to identify any faulty hardware. [community thread]

Can I install an RTX A4000 GPU in my R760 server if the power connector types don't match?

You can use the CPH58 cable to connect the 8-pin riser to the 6-pin input of the RTX A4000, as it appears to be compatible. However, the A4000 is not officially listed as supported for the R760, so results may vary. [community thread]

Why is my R740 server's fan speed higher after updating the firmware?

An increase in fan speed can occur due to changes in iDRAC firmware that adjust thermal management settings for better cooling. If the Intel X710 network card is causing excessive fan activity, consider reviewing the system's thermal profile settings or fan offsets, as outlined in the Dell EMC documentation. [community thread]

Why can't I find the RAID 10 option for the PowerEdge R6615 during configuration?

The RAID 10 option may not be visible due to configuration settings or limitations in the sales tool. It is advisable to reach out to sales support for potential overrides or further assistance, as the H755 controller does support RAID 10. [community thread]

What is the recommended upgrade path for the BIOS and iDRAC firmware on a Dell PowerEdge T340 server?

To upgrade the BIOS and iDRAC firmware on a Dell PowerEdge T340, start with the BIOS updates followed by the corresponding iDRAC updates, ensuring to reboot between each update. The recommended sequence is: 2.4.1, 4.22.00.00, 2.6.3, 4.32.10.00, 2.8.3, 4.40.40.00, 2.10.1, 5.00.20.10, 2.12.2, 5.10.50.00, 2.14.1, 6.10.30.20, 2.17.3, and finally 7.00.00.175. [community thread]

What should I do if my PowerEdge R640 shows error code 2000-0251 and keeps rebooting?

Error code 2000-0251 usually indicates a memory-related issue. First, run the extended memory diagnostics by booting into the hardware diagnostics menu. Additionally, check that the memory modules are properly seated, and consider testing the server with a minimal memory configuration to identify any faulty modules. [community thread]

Why are my R740XD2 servers running DIMMs at 2666MT/s instead of 2933MT/s?

The R740XD2 servers manufactured before 2021 may not support 2933MT/s due to the absence of the required MLK V2 motherboard. To determine compatibility, check the part numbers of both the DIMMs and the motherboard. [community thread]

What does the RED097 error mean when updating firmware on a Dell R730XD?

The RED097 error indicates that the firmware image you are trying to install is not compatible with the components recognized in the system inventory. This can happen if the device has been updated to a version that is not yet listed in the firmware catalog, which is updated quarterly. [community thread]

What is the recommended upgrade path for the iDRAC and BIOS on PowerEdge R6515 and R6615 servers?

For both servers, it is advisable to update the iDRAC firmware first, followed by the BIOS. Ensure to check the specific firmware requirements on the manufacturer's driver page, and aim to make one major version jump at a time to avoid compatibility issues. Always perform updates during low-load periods and create backups beforehand. [community thread]

How can I fix the CPU0704 machine check error on my server?

To address the CPU0704 machine check error, first ensure that your server's firmware, including BIOS and iDRAC, is updated to the latest versions. If the issue persists, run hardware diagnostics by booting into the Lifecycle Controller during POST. [community thread]

Why can't I disable Virtualization Technology (VT-x) in the BIOS of my PowerEdge R470?

The inability to disable Virtualization Technology in the BIOS is likely by design and may relate to the server's hardware configuration. For further assistance, it is recommended to contact technical support, especially since the R470 is a newer model and should still be under warranty. [community thread]

Is the CP-104EL-A-DB9M 4 Port PCIe Board compatible with the Dell R360 server?

Dell has not officially validated the CP-104EL-A-DB9M board for use with the R360 server, so compatibility is uncertain. You may want to check the server's riser and slot specifications in the installation manual to see if it fits. [community thread]

Can I mix 3200 MT/s and 2933 MT/s RAM in a Dell PowerEdge R6515 server?

Yes, you can mix RAM speeds, but the system will automatically adjust the speed of all installed DIMMs to the lowest speed, which in this case would be 2933 MT/s. It is advisable to use identical DIMMs for optimal performance, so sourcing the same original parts is recommended. [community thread]

Can I install two different network interface cards (NICs) in the R340 server?

Yes, the R340 server supports the installation of two different NICs. However, ensure that the specific models you choose are compatible, as not all cards may be supported. [community thread]

Why won't my Dell PowerEdge R740xd boot from NVMe SSDs connected via an ASUS Hyper M.2 PCIe adapter?

The Dell PowerEdge R740xd's BIOS does not support booting from NVMe drives connected through third-party PCIe adapters. Although the drives are recognized during installation, the BIOS cannot identify them as bootable devices, leading to boot failures. [community thread]

Where can I find a replacement bracket for the Dell R6515 server?

The specific bracket (Dell P/N: PDP39) may not be available through official Dell parts channels. Consider checking online marketplaces or forums for user recommendations, and you can also explore general search engines for potential sources. [community thread]

Is the Dell part# 03THTT (600W 80 Plus Platinum) power supply compatible with the PowerEdge R640?

The Dell part# 03THTT is designed for 15G and 16G servers, and it is not compatible with the PowerEdge R640. [community thread]

Why does my Dell PowerEdge R630 server shut down unexpectedly after a few hours of use?

To diagnose the issue, check the Lifecycle Controller logs and the operating system logs for any errors. You can also run a diagnostic tool to identify potential problems, or consider submitting a support ticket for further assistance. [community thread]

How can I upgrade the CPU in a Dell PowerEdge T430 server?

To upgrade the CPU in a Dell PowerEdge T430, first ensure that the system board firmware, including iDRAC and BIOS, is updated. The server supports two Intel Xeon E5-2600 v4 or v3 processors, so refer to the owner's manual for guidelines on CPU and memory configurations. [community thread]

How can I boot from SSD hard drives on an R750xs server?

To boot from SSDs on the R750xs, ensure you have the OS driver pack installed. You can update the driver pack using the Lifecycle Controller by copying the file to a USB device, accessing Platform Update, and executing the installation. [community thread]

What should I do if I encounter an error while updating the firmware on my Dell T630 using iDRAC?

First, check your firewall settings as the error may be related to network access. If using a USB stick, try a different port, reformat the stick to FAT32, and ensure the .d7 file is located in the root directory. Alternatively, you can upload the .d7 file directly through the iDRAC web interface. [community thread]

What components are needed to install two NVIDIA H100 PCIe GPUs in a DELL PowerEdge R760xa server?

To install two NVIDIA H100 GPUs in a DELL PowerEdge R760xa, ensure you have the appropriate riser configuration and install the GPUs in slots 31, 33, 36, or 38. You will also need power cables, specifically part number 470-BCTG, for both the left and right connections. For further assistance, consider reaching out to server support after gathering the necessary components. [community thread]

What do the blinking DS5 and DS6 LEDs indicate on a Dell EMC T640 server that won't power on?

The blinking DS5 and DS6 LEDs typically suggest a hardware issue. To troubleshoot, ensure that the server has the minimum configuration required to POST, which includes one CPU in socket 1, one memory module in socket A1, and at least one power supply unit. [community thread]

Is the Broadcom NetXtreme II 10 GB-2 port PCI Express x8 compatible with the PowerEdge R250 server?

The Broadcom NetXtreme II 10 GB-2 port PCI Express x8 is not compatible with the PowerEdge R250 server, as it is designed for use with up to 14G models, while the R250 is a 15G model. [community thread]

How can I resolve hardware errors on an R640 server that frequently shuts down?

Start by updating the BIOS and iDRAC firmware. If the problem persists after these updates, consider contacting support for potential part replacements. [community thread]

What graphics card can I use to upgrade my PowerEdge T630 for dual HDMI outputs?

The only graphics card listed for the T630 is the Nvidia GeForce GTX 1080, which features one HDMI port along with DVI and DisplayPort options. For dual HDMI outputs, you may need to use adapters or explore community suggestions for alternative solutions. [community thread]

What should I do if only some ports on my Intel X550 OCP network card update successfully while others fail?

Try resetting each NIC port to default settings through the device configuration menu, then reboot the server. After rebooting, power down the system, disconnect the power cords, and use iDRAC to load a firmware version that is between the current versions of the ports to facilitate a proper upgrade. [community thread]

What should I do if my R630 server won't boot and shows voltage errors for CPU 2?

The voltage error suggests a potential issue with CPU 2. Try swapping CPU 1 with CPU 2 while keeping only essential components connected, then power on the server to see if the error persists. If the problem continues, revert the CPUs and check if the error follows CPU 2, indicating it may be faulty. [community thread]

What should I do if my T430 is not detecting all installed memory modules?

The memory detection issue may stem from using incompatible RAM types or faulty modules. Test each RAM stick individually in different slots, and ensure that you are using only one type of RAM at a time. Additionally, check for any motherboard issues or consider replacing any modules that show errors. [community thread]

What should I do if my Dell PowerEdge R630 server shuts down after an hour of operation?

The Dell PowerEdge R630 may not be compatible with Windows Server 2022, which could lead to driver or hardware issues. To troubleshoot, try running the server in BIOS for over an hour to see if it still shuts down, and ensure that the server's firmware is up to date. Additionally, check the Windows event logs and BIOS logs for any hardware errors. [community thread]

Does the Dell R760xs support Advanced ECC?

The Dell R760xs does not support Advanced ECC; instead, it features Optimizer Mode, Dell Fault Resilient Mode (FRM), and Dell NUMA Fault Resilient Mode (FRM). For more details, refer to the documentation on pages 43 and 44. [community thread]

Why is only one Emulex HBA detected in my R760 server after installation?

Ensure that the HBAs are installed according to the slot priority specified in the server's installation manual. If the issue persists after following the guidelines, consider opening a support ticket for further assistance. [community thread]

What are the compatible 25GBE SFP28 cards for the R7515 server?

The compatible 25GBE SFP28 cards for the R7515 server can be identified using the 'Customer Kit' SKU specifically for APOS. A detailed compatibility matrix is often available in community forums or technical documentation. [community thread]

Why does Hyper-V installation fail with a message about virtualization not being enabled despite it appearing enabled in the BIOS?

This issue may arise if the workload profile in the BIOS has disabled virtualization options. To resolve this, access the BIOS settings, navigate to the workload profile, and switch to either 'Virtualization - Power Efficient' or 'Virtualization - Max Performance'. If options remain greyed out, resetting the BIOS to default settings may also help. [community thread]

Why is my HPE DL380 Gen10 server not detecting the PCI-E riser card 809461-001?

Try reseating the PCI-E riser card to ensure a proper connection. If the issue persists, test with a different, known working riser card to determine if the problem lies with the riser or the server's motherboard. [community thread]

Why are the cpqDaPhyDrvLocationString values inconsistent in SNMP traps for my server's hard drives?

Inconsistent values for cpqDaPhyDrvLocationString in SNMP traps can occur due to variations in how the iLO reports drive status. It is advisable to check for firmware updates, as newer versions may address these discrepancies. [community thread]

How do I install RAM in an HPE ProLiant DL380 Gen10 Plus server?

To install RAM in the HPE ProLiant DL380 Gen10 Plus, refer to the memory population guidelines specific to your server model. Ensure that the RAM type and processor are compatible, and consult the documentation for the correct slot configuration. [community thread]

How can I resolve the 'Base System Device' issue on my HPE ProLiant DL380 Gen11 after installing Windows Server?

To fix the 'Base System Device' issue, download and install the Intel chipset driver from the HPE Support Center for your ProLiant DL380 Gen11. Alternatively, you can use the HPE Service Pack for ProLiant (SPP) to automatically install the necessary drivers. After installation, reboot the server and check Device Manager to ensure the devices are correctly identified. [community thread]

What should I do if my HP Proliant DL380 Gen10 fans are excessively noisy after an ILO5 firmware update?

If you experience increased fan noise following an ILO5 firmware update to version 3.04, downgrading to version 3.03 may resolve the issue. You can download the previous version and update the firmware through the ILO5 dashboard to restore normal fan operation. [community thread]

What should I do if my ML350 Gen10 server fails to POST and shows an error about the serial number?

It seems there may be a hardware issue with your server. Try powering on the server with a minimal configuration by removing all add-on cards. If the problem persists, consider contacting HPE support for further assistance. [community thread]

Do I need extra cables or backplanes to connect both SATA and NVMe drives in the HPE ProLiant DL325 Gen11?

Refer to the server's quickspecs and cabling guide for detailed information on required components. It's advisable to check the compatibility of your SATA and NVMe drives with the existing setup to determine if additional kits are necessary. [community thread]

Why is my BCM 57416 OCP3 Adapter only showing 1 Gbps speeds instead of 10 Gbps?

Ensure that the switch or router port is capable of 10 Gbps and is set to auto-negotiate or manually configured for that speed. Additionally, check the NIC settings in the operating system or BIOS to confirm that the speed is not locked at 1 Gbps. If issues persist, try installing the adapter in a different OCP slot. [community thread]

Why does my SATA RAID array show as an HDD instead of an SSD in the operating system?

SATA SSDs do not support the UNMAP command, which is a requirement for the operating system to recognize them as SSDs. Consequently, the OS may classify the SATA RAID array as an HDD, leading to features like defragmentation being enabled. Disabling defrag is advisable, but be aware that without TRIM support, performance may degrade over time. [community thread]

What should I do if I see 'Other Devices' listed in Device Manager on my DL380 Gen10 running Windows Server 2025?

The 'Other Devices' entries are usually due to missing HPE chipset or management interface drivers. To resolve this, ensure that you have installed the HPE iLO Channel Interface Driver and the latest Intel chipset drivers, as well as the HPE Agentless Management Service. If issues persist, check for updates to your iLO firmware and Smart Array drivers. [community thread]

How can I resolve the 'could not dequeue a packet' error when updating firmware on a ProLiant DL380 Gen12 server running Ubuntu 24.04 LTS?

This error typically means that the server is unable to communicate with iLO 7 via the Virtual NIC. Ensure that the Virtual NIC is activated, that the operating system recognizes it, and that the server can access the iLO VNIC address. Additionally, confirm that you are using the latest versions of the Gen12 SPP and SUM, and check the compatibility of the iLO firmware. [community thread]

Why are only 10 out of 12 drives detected on my DL380 Gen10 with the S100i controller?

The S100i controller may not support all 12 drives due to hardware limitations. It is advisable to check the compatibility of the drives being used and consider upgrading to a dedicated Smart Array controller for full support of all 12 drives. [community thread]

Why are the fans running at high speed after installing a 10Gbps Ethernet card in a DL320 Gen11 server?

High fan speeds may occur if the installed Ethernet card does not provide accurate thermal readings to the server's management system. Consider using HPE-branded network interface cards, as they are more likely to communicate effectively with the server's iLO and regulate fan speeds appropriately. [community thread]

What does an amber light indicate on my HP ProLiant DL360 Gen10 server?

An amber light on your HP ProLiant DL360 Gen10 server typically signals a hardware issue. For further assistance, consult the Service and Maintenance Guide from the HPE Support Center or check related forum discussions regarding similar problems. [community thread]

How do I configure the MR416i controller on my HPE Proliant DL360 Gen10 Plus to recognize SAS drives for OS installation?

To set up the MR416i controller, access System Utilities by pressing F9 during POST. Navigate to System Configuration > HPE MR416i-a Gen10+, create a logical drive by selecting the RAID level and drives, then apply and save the configuration to ensure the system recognizes the drives for OS installation. [community thread]

Why is the RAID disk not showing up during the installation of CentOS 7.2 on a DL380 Gen10 with a P408i-a RAID controller?

The issue may be related to the firmware version of the RAID controller. Updating to the latest firmware version could resolve the problem, as earlier versions may not support CentOS 7.2 properly. [community thread]

How can I update firmware for a component via iLO while VMWare is running on my server?

To update firmware through iLO without disrupting VMWare, upload the firmware file in the firmware update section of iLO. The installation typically occurs online, and you can reboot the server at your convenience to activate the new firmware. [community thread]

Can I replace a failed hard drive in a RAID 5 configuration with a larger but slower drive?

Yes, you can substitute a failed drive with a larger capacity, but the RAID configuration will default to the size of the smallest drive in the array. While it's possible to use a slower drive, be aware that this may affect overall performance. [community thread]

What is the maximum hard disk capacity for the HPE ProLiant DL20 Gen10 server?

The HPE ProLiant DL20 Gen10 can accommodate a maximum storage capacity of up to 48 TB, depending on the specific storage configuration used. [community thread]

Why is my DL360 Gen11 server not recognizing HPE NVMe drives?

Ensure that Intel VMD and Intel VROC are enabled in the RBSU settings. Additionally, verify that the NVMe drives are properly connected to the correct backplane and that the cabling is intact. If issues persist, consult the Intel VROC documentation for further troubleshooting steps. [community thread]

Why is my HPE Proliant DL20 Gen10 server making excessive fan noise while running FreeBSD?

To address loud fan noise, access the iLO web interface and check the fan status and speed under the System Information section. If the fan speed is consistently above 60% and the noise persists, consider opening a support case with HPE for further assistance. [community thread]

What should I do if I encounter a REST API error with my ProLiant DL380 Gen10 server's iLO firmware?

To resolve the REST API error, try resetting the iLO from the console and then SSH into the iLO to execute the command 'oemhp_clearRESTAPIstate'. After that, reboot both the server and the iLO by shutting down the server, disconnecting all power sources and cables, reconnecting them, and powering the server back on. [community thread]

How many drive bays, memory slots, and PCIe slots can I use with a single CPU in a DL360 Gen11 server?

With one CPU in a DL360 Gen11 8 Bay SFF server, all 8 drive bays are accessible. You will have 16 DIMM slots available for memory, and for PCIe slots, there is one primary riser with a combination of 1x16 FH and 1x16 LP slots. For detailed specifications, consult the HPE DL360 Gen11 Quickspecs guide. [community thread]

Why is the write performance slow on my ML110 Gen11 with VROC sSATA SoftRaid Array?

If you are experiencing slow write speeds and cannot enable the write cache, ensure that the appropriate storage drivers are installed, as missing drivers can affect performance. [community thread]

How can I resolve a 270 iLO communication error on my DL360 Gen10 server?

To fix the 270 iLO communication error, first update the iLO Firmware to version 2.02 or higher and the BIOS to version 1.20_08-26-2014 or later. If the problem continues, power down the server, disconnect the power supply, wait for 30-60 seconds, and then reconnect it. [community thread]

Why can't I access the firmware update repository through Intelligent Provisioning on my server?

If you're unable to reach the firmware update repository, ensure that your network settings are correctly configured and that the server has internet access. Additionally, verify that the URL for the firmware repository is correct and accessible from other devices; if it returns a 'Forbidden' error, the issue may be with the repository itself rather than your server's configuration. [community thread]

Why is my ML110 Gen10 server's fan running loudly and at high speeds after an upgrade?

After a firmware upgrade, high fan speeds may occur due to various factors. Check for any unnecessary PCI cards and remove them, test the fans in UEFI mode, and ensure all fans are functioning properly. Additionally, monitor the temperature readings in the iLO interface to identify any potential issues. [community thread]

What Intel CPUs are compatible with the DL20 Gen10 server?

The DL20 Gen10 server supports specific Intel Xeon E processors, primarily the E-2200 and E-2100 series. For the most accurate and up-to-date compatibility information, refer to the latest QuickSpecs from the manufacturer. [community thread]

How can I connect a U.3 NVMe drive to a DL20 Gen11 server?

To successfully connect a U.3 NVMe drive to a DL20 Gen11 server, you need to ensure that the backplane and cabling support NVMe and are connected to PCIe lanes. The P65406-B21 kit alone only enables SATA/SAS drives, so you will require an NVMe backplane or a PCIe HBA that supports U.3 tri-mode NVMe drives. [community thread]

What should I do if the fans on my HPE ProLiant DL360 Gen11 are running at medium speed frequently?

To troubleshoot the fan speed issue, access iLO 6 to monitor fan speeds, thermal readings, and event logs when the fans increase in speed. Ensure that iLO 6, BIOS, and SPP are updated to their latest versions, and consider analyzing the AHS log for any components causing the issue. You can also adjust fan settings in the Power & Thermal section to optimize cooling performance. [community thread]

Why does my ML350 Gen10 server power up all fans to maximum every 26 hours?

This issue may be related to firmware or embedded system settings rather than user activity. To troubleshoot, check the iLO logs during the fan spike, verify BIOS/iLO versions, consider downgrading iLO for testing, ensure AMS is functioning properly, and monitor hardware sensors. If the problem persists, contact HPE Support for further assistance. [community thread]

How can I check the array status via SNMP on a ProLiant ML350 Gen10?

To monitor the array status using SNMP on the ProLiant ML350 Gen10, ensure you are using the correct OID, which is 1.3.6.1.4.1.232.3.2.2.1.1.6 for cpqDaCntlrCondition. If you receive a NULL value, consider downloading the SIM MIB kit and refer to the documentation for compiling and customizing SNMP MIBs for further assistance. [community thread]

What should I do if my ML350 Gen10 server does not POST and shows an internal processor error?

If your ML350 Gen10 server fails to POST and indicates an internal processor error, first ensure that the CPUs are properly seated and compatible. You may also need to clear the NVRAM/CMOS by following the appropriate steps in the server manual. If the issue persists, consider checking for additional error codes, updating or rolling back the firmware, and inspecting other hardware components. [community thread]

What should I do if I can't re-add my DL380 Gen10 servers to OneView?

Ensure that your network settings are correct and that the servers are reachable. You may want to review the documentation for adding servers to OneView and consider resetting the iLO configuration or checking for any certificate issues. [community thread]

Why are some drives not appearing for RAID configuration on my HPE DL380 Gen10 server?

When configuring RAID arrays, ensure that all drives are of the same type, as mixing different types like SAS, SATA, and SSDs is not allowed. If some drives are not visible, they may be in Mixed Mode, which presents them directly to the OS instead of the RAID controller; check the controller settings to adjust this. [community thread]

What should I do if my Proliant DL380 G11 shows no display after SPP installation?

After updating the SPP, check the BIOS or UEFI settings as they may have been altered. Resetting to default settings could resolve the issue. Additionally, if using iLO for remote management, ensure it is functioning properly and can access the server's console. [community thread]

Why is my ML110 Gen11 RAID controller only detecting 4 out of 5 SSDs?

To resolve this issue, ensure that RAID is properly configured using the RBSU in the BIOS. The server's embedded storage controller supports specific drive group configurations, so verify that the drives are correctly assigned to their respective groups. [community thread]

Why can't I see any drives during the OS installation on my HPE Proliant DL360 Gen10 Plus?

The issue may arise because the Smart Storage Admin within Intelligent Provisioning does not support MR controllers. To resolve this, consider upgrading the Intelligent Provisioning version or use the F9 utilities during POST to configure the RAID controller. [community thread]

What should I do if my DL380 Gen10 server fails to boot with a Tesla V100 GPU?

If your server is not booting with a Tesla V100 GPU and shows a power failure and riser seating issue, try reseating or swapping the riser, updating the ILO and BIOS firmware, and switching the power supply to High Performance mode. Additionally, testing with minimal hardware may help determine if the issue is related to the riser, power draw, or firmware. [community thread]

Why are the drives in my DL380 Gen11 servers not showing up correctly?

Ensure that your server is updated with the latest HPE Service Pack for Proliant (SPP), as this can resolve drive detection issues. You can download the latest SPP from the HPE support website. [community thread]

Why does iLO indicate a critical status for the storage controller when ssacli shows everything is fine?

This issue is known to occur with HPE ProLiant Gen10/Gen10 Plus servers, where iLO may incorrectly report a critical status due to stale sensor data or misinterpretation of cache states. To resolve this, perform a full power cycle of the server to clear sensor states, or use the iLO CLI to force a hardware health rescan. Additionally, ensure that both iLO and Smart Array controller firmware are updated to the latest versions. [community thread]

Why does my HPE DL20 Gen10 server have high fan speeds when drives are installed?

High fan speeds can occur if the server detects incorrect temperature readings from the installed drives. It may be helpful to test each drive individually to identify if one is causing the issue. [community thread]

What is the maximum memory speed supported by the HPE Part Number P67095-B21 processor?

The HPE Part Number P67095-B21, which features the Intel Xeon Gold 6530 processor, supports a maximum memory speed of 4800 MT/s. Although it is compatible with PC5-5600B and PC5-5200B memory modules, these will operate at the lower speed of 4800 MT/s due to the processor's limitations. [community thread]

How can I obtain MIB files and OID values for monitoring an HPE ProLiant DL380 Gen10 Server?

You can download the HPE System Insight Manager - MIB Kit, which includes all necessary MIB files for monitoring various server parameters. For specific OIDs related to issues like hard disk failures, CPU usage, and temperature, refer to the documentation on compiling and customizing SNMP MIBs with HPE SIM. [community thread]

How can I add more drives to a DL380 Gen10 that currently has a DVD ROM occupying drive slots?

To add more drives, you will need to replace the front drive cage that currently holds the DVD ROM, as simply removing the DVD drive will not free up the slots. After removing the DVD ROM assembly, install a compatible drive cage that supports the desired number of drives, and ensure the backplane is suitable for the additional drives. [community thread]

Why won't my SAS drive fit into the drive cage of a DL380 Gen10 server?

The issue may be due to the design of the drive cage, which can have tabs that obstruct the drive carrier from fully connecting. To resolve this, check if the drive cage is compatible with the specific drive model, as some cages are intended for different types of drives such as NVMe or SSD. [community thread]

Can a DL380 Gen10 server boot with only the second CPU installed?

No, the server requires the first CPU socket to be populated for it to function correctly. Operating with only the second CPU installed is not a supported configuration and will prevent the server from booting. [community thread]

Why is there no video output to the monitor after the operating system loads on my server?

Check the BIOS settings for the Embedded Video Connection and ensure it is set to 'Always enable.' Additionally, verify that the System ROM (BIOS) and iLO firmware are updated to the latest versions, as firmware updates can resolve video output issues. [community thread]

Why are my U.2 disks not being detected in the HP DL385 Gen10 Plus server?

The issue may stem from using SAS RAID controllers, which cannot recognize NVMe drives like the Intel P4610. To resolve this, ensure that the backplane is NVMe-capable and connected to an appropriate NVMe controller, or consider replacing the drives with HPE-certified SAS drives for compatibility. [community thread]

Why is PCIe Slot 4 not appearing in the BIOS bifurcation options on the ML350 Gen10?

The absence of PCIe Slot 4 in the BIOS bifurcation menu may be due to specific hardware limitations or motherboard configurations. It's advisable to consult the server's QuickSpecs or User Guide for detailed information on the bifurcation capabilities of each slot. [community thread]

Why does the iLo 5 Remote Console display a black screen on my DL380 Gen10 server?

To resolve the black screen issue with the iLo Remote Console, consider clearing the server's NVRAM. Additionally, enabling persistent mouse and keyboard settings in the Power and Thermal section may help. For further assistance, refer to the relevant advisory from the manufacturer. [community thread]

What should I do if my HPE ProLiant DL360 Gen10 server shows a persistent memory configuration error during POST?

The error indicates that the System Programmable Logic Device (PLD) firmware is outdated. To resolve this, ensure the PLD is updated by booting into Intelligent Provisioning and running the firmware update using the Service Pack for ProLiant (SPP). If the PLD does not update, consider contacting HPE support for further assistance. [community thread]

What should I do if my Proliant DL560 Gen10 server stalls during memory initialization with a quad socket configuration?

To resolve this issue, try changing the power supply configuration to 2+2 redundancy or 3+1, and ensure the integrity of the CPU socket pins. Additionally, reseat the mezzanine board, clear the NVRAM, and reset the BIOS/UEFI settings to default. Testing different CPU pairings and adjusting the RAM configuration may also help. [community thread]

Why is my ProLiant DL20 Gen11 server making a lot of noise?

To reduce noise, consider updating the System ROM to version 2.44 and ensuring all firmware and drivers are current with the latest SPP. Additionally, rearranging drives to increase spacing can help lower fan speeds, and adjusting the minimum fan speed settings in the iLO interface may also be beneficial. If noise remains a concern, using SATA SSDs can significantly decrease operational noise. [community thread]

What should I do if my HPE Smart Array controller shows a warning and performance issues after a disk failure?

The cache may be temporarily disabled due to the controller or its firmware. It is advisable to open a support case and provide the latest AHS and ADU logs for a thorough analysis. [community thread]

Why is my ML110 Gen11 server's fan so noisy?

Increased fan noise can occur due to the server's cooling requirements, which may not always correlate with workload or temperature. Ensure that the thermal configuration is optimized and that no additional hardware is affecting performance. If the noise remains excessive, consider adjusting the workload profile or consulting support for further assistance. [community thread]

Is there an online configuration utility for the DL380 Gen12 with iLO7?

No, there is no online configuration utility available for the DL380 Gen12 with iLO7. HPE has discontinued host-based configuration tools for newer ProLiant generations, and management is now primarily conducted through the iLO Web GUI, RESTful API, or scripting options. [community thread]

What should I do if my DL380 Gen10 server is showing erroneous overtemperature shutdown errors after a VMware update?

This issue may be related to a faulty temperature sensor or hardware component. It is advisable to check the installation of fans, heat sinks, and air baffles, and to consult HPE support for further diagnosis and assistance. [community thread]

What should I do if my DL380 Gen12 fails to update using the SPP?

Ensure that you are running the Smart Update Manager (SUM) in local mode by executing the launch_hpsum.bat file as an Administrator. Verify that the SPP ISO is correctly mounted and that the necessary service ports (63001 for HTTP and 63002 for HTTPS) are accessible. If issues persist, consider updating directly through the iLO interface or using the iLO remote console for interactive updates. [community thread]

Why is the memory remap option missing in the DL385 Gen10 server after a memory replacement?

The absence of the memory remap option in the BIOS/UEFI settings for the DL385 Gen10, which uses AMD EPYC processors, is normal as memory remapping is typically managed automatically by the processor architecture rather than being a configurable setting. For further details, consult the server's quick specifications. [community thread]

Why is the performance of my HPE Smart Array P408i-a SR Gen10 poor with certain RAID configurations?

The subpar performance in RAID5 and RAID1 is likely due to the absence of a physical cache module, which is necessary for enabling write-back caching. Without this module, the controller operates in write-through mode, resulting in slower write speeds. To improve performance, ensure a compatible cache module is installed and that the appropriate licenses for caching are applied. [community thread]

What should I do if my HPE ML30 Gen11 server won't power on with four memory modules installed?

To troubleshoot this issue, first perform a power drain by disconnecting the power supply and holding the power button for a few seconds. Then, ensure that the memory modules are installed according to the manufacturer's guidelines, testing each module and slot individually. Additionally, check the BIOS settings to confirm that there are no configurations preventing the use of all four memory slots. [community thread]

Why can't I configure NVMe disks in RAID 0 on my ML350 Gen11 using Intel VROC?

Ensure that Intel VROC is enabled in the system settings. Refer to the Intel Virtual RAID on CPU for HPE Gen11 User Guide for detailed instructions on the setup process. [community thread]

What is the performance difference between M.2 NVMe SSDs connected via the HPE ProLiant DL20 Gen11 M.2 Enablement Kit and a PCIe card?

The M.2 Enablement Kit is limited to a single PCIe lane, resulting in lower performance, typically around 800MB/s, compared to approximately 3GB/s when using a PCIe card. This design choice prioritizes basic functionality over high throughput, and the DL20 Gen11 does not support PCIe bifurcation for connecting multiple M.2 drives with full bandwidth. [community thread]

How do I connect the NVMe backplane to the Mega Raid Controller MR416i-p in a DL380 Gen10 server?

To connect the NVMe backplane (part number 872971-001) to the Mega Raid Controller MR416i-p, refer to the official HPE support documentation for detailed instructions on cable connections. Ensure that the cables are properly connected and check the controller settings to configure RAID for the NVMe drives. [community thread]

What should I do if I receive a TPM warning while updating firmware on my HPE DL380 Gen10 Plus server?

Before proceeding with the firmware update, ensure that you have any necessary recovery passwords for the TPM features configured in your operating system. It is advisable to review the server's documentation for guidance on handling TPM warnings during firmware updates. [community thread]

What should I do if my ProLiant DL380 Gen11 server freezes and shows an NMI switch event?

The freezing issue is likely due to a mismatch between hardware, firmware, and drivers. To resolve this, ensure all firmware is updated to the latest versions, install the HPE SUSE Linux Driver Pack for SLES 15 SP7, and check system logs for any lockup errors. Additionally, apply any necessary SUSE kernel patches for SP7. [community thread]

What should I do if my HPE ML 110 Gen10 is stuck in a reboot loop during system chipset initialization?

Try disconnecting any unnecessary PCI cards or external devices that may be connected. Additionally, check the IML log in iLO for any error messages and consider clearing the NVRAM using the System Maintenance Switch on the system board. [community thread]

Why does Firefox close automatically after deploying SPP on my HP DL380 Gen11 with Windows Server 2025?

This issue may be caused by post-deployment scripts, Group Policies, or security software interfering with Firefox. To troubleshoot, check for any scripts or policies that could be terminating the application, review Firefox's compatibility with Windows Server 2025, and examine deployment logs for errors. Additionally, consider disabling antivirus temporarily or testing a manual launch of Firefox after deployment. [community thread]

What RAID configurations are supported for NVMe SSDs in a DL360 Gen10 server?

NVMe SSDs do not work with hardware RAID controllers, as these controllers are designed for SAS and SATA drives. NVMe drives connect directly to the CPU via PCIe lanes, which means they cannot be configured in RAID using traditional hardware RAID methods. [community thread]

How can I manage the RAID controller on an HPE DL380 Gen10 Plus running ESXi 8.0?

To manage the RAID controller, you can use the UEFI System Utilities for initial configuration. For ongoing management, the HPE MegaRAID Storage Administrator (MRSA) tool may not be available, but you can utilize the StorCLI command-line interface to check the status and configure the RAID settings. [community thread]

What should I do if my ProLiant DL360 Gen10 server is not recognizing RAM or showing errors?

First, ensure that all DIMMs are properly seated and compatible with your server. If the issue persists, check that both processors are correctly installed and functioning. Additionally, try running the server with minimal hardware configuration to isolate the problem. [community thread]

How can I update the firmware on a DL20 Gen11 server to resolve ASR reboot issues?

To update the firmware on a DL20 Gen11 server, it is recommended to use the Service Pack for ProLiant (SPP). Download the SPP and follow the instructions to ensure all firmware is updated correctly. If you encounter issues, consider using a virtual ISO image via iLO to boot and apply the updates. [community thread]

Can I add an Nvidia GPU to a Proliant DL160 Gen10 server for AI experiments?

Yes, it is feasible to add an Nvidia GPU, but you must consider factors such as power supply, physical space, cooling requirements, and available PCIe slots. Ensure that you have a suitable PCIe x16 slot and that your power supply can handle the GPU's power demands. If the GPU does not fit internally, you can use an external PCIe expansion chassis. [community thread]

What should I do if I encounter a 404 error when trying to access RBSU in AOIP on my HP DL360 Gen10 server?

This error may indicate a version mismatch or stale data in the system. While managing RBSU through the F10 key works correctly, consider checking for updates or resetting the iLO settings, but be cautious as clearing NVRAM can lead to lockout issues. [community thread]

What should I do if I encounter an NVIDIA driver installation error on an HPE DL385 Gen11 server with A100 GPUs running Ubuntu?

To resolve the driver installation issue, ensure that your BIOS and firmware are updated, enable Above 4G Decoding and Resizable BAR in the BIOS, and use a compatible NVIDIA driver such as version 535-server. Additionally, disable Secure Boot during installation and consider installing the HPE NVIDIA Enablement Kit if necessary. [community thread]

What does POST code 0033 indicate on a DL380 Gen10 server?

POST code 0033 typically signifies an issue related to the server's boot process, often linked to array encryption key retrieval problems. If you encounter this code, check for any connected devices, such as USB drives, that may interfere with the boot sequence. [community thread]

Why does the syslog entry reset after updating the iLO firmware on DL360 Gen11 servers?

It appears that updating or downgrading the iLO firmware on DL360 Gen11 servers consistently results in the loss of the syslog entry, while other logs like IML remain unaffected. This issue has been observed across multiple Gen11 servers and seems to occur regardless of the firmware version applied. [community thread]

How can I resolve event ID 1801 on my HPE ProLiant DL 380 Gen11 server after a Windows update?

This issue is related to the Windows Secure Boot Database. To fix it, reboot the server and access System Utilities by pressing F9, then navigate to Server Security in the BIOS/Platform Configuration. Look for options to apply or restore the Secure Boot Database, apply the changes, and perform at least two full reboots to ensure synchronization. [community thread]

Can I check the TPM Override box when upgrading the iLO firmware on a DL380 Gen10 server without using BitLocker?

Yes, if you are not using BitLocker or any other TPM-dependent features, you can safely check the TPM Override box and proceed with the firmware upgrade. This precaution is mainly for systems with active TPM-bound security features, as firmware updates can affect TPM measurements. [community thread]

How can I find and update the latest firmware for my ProLiant DL325 Gen10 server components?

To obtain the latest firmware for your ProLiant DL325 Gen10, it is recommended to use the Service Pack for ProLiant (SPP), which includes all necessary updates for components like the Smart Array and NIC. You can download the SPP from HPE's support site, and it will automatically detect your hardware and apply updates in the correct order. If you encounter issues with the Smart Array, ensure to update to version 5.61 first before proceeding with further updates. [community thread]

What should I do if my server's disks and RAID show a Degraded (Not authenticated) status?

Check that the firmware for both the drives and the RAID controller is current. If the problem continues, power down the server, reseat the drives, and observe if the status changes. If the issue remains, consider testing with a replacement drive to help identify the cause. [community thread]

How can I change the AMP Mode from A3DC to Advanced ECC on a DL380 Gen10 server?

If the AMP Mode is stuck on A3DC, try switching to a custom profile, as this has resolved the issue for other users. After selecting the custom profile, you should be able to set Advanced ECC successfully. [community thread]

How can I configure PCI passthrough settings for VDI VMs on HP Proliant DL380 Gen11 servers?

To configure PCI passthrough settings, first access the UEFI System Utilities during server boot and check for options related to 'Memory Mapped I/O above 4 GB' and 'Above 4G Decoding' under PCI configuration. Ensure your VMs are set to use UEFI/EFI firmware instead of legacy BIOS. If the necessary options are not available, consider contacting HPE support for clarification on the server's capabilities. [community thread]

How can I configure RAID 10 with an MR416i-p on a DL380 Gen10 server using NVMe drives?

To set up RAID 10 with the MR416i-p on a DL380 Gen10, ensure you have the correct HPE Tri-Mode cable kit (P55467-B21) and that the MR416i-p is installed in the appropriate x16 slot. Connect the SlimSAS cable from the MR416i-p to the backplane, and then boot the server to access the RAID configuration utility to create your RAID 10 array. [community thread]

What CPUs are compatible with the HPE ProLiant DL20 Gen10 server?

The HPE ProLiant DL20 Gen10 server officially supports specific CPUs, including the 9th generation i3. While the socket may physically accommodate i5 and i7 processors, compatibility depends on factors such as power requirements and motherboard support, which are outlined in the QuickSpecs documentation. [community thread]

Why is Windows Server 2016 not detecting the HPE Smart Array Controller P408i-P SR Gen10?

To resolve detection issues with the HPE Smart Array Controller P408i-P SR Gen10 in Windows Server 2016, download and install the appropriate driver for the controller. This may help the operating system recognize the controller during installation. [community thread]

Can I disable a physical CPU in a DL380 Gen10 server through OneView or BIOS?

Disabling a physical CPU in the DL380 Gen10 is not feasible through OneView or BIOS, as these interfaces only allow for core disabling. The only method to disable a CPU is by physically removing it, which may not be practical in many situations. [community thread]

Why does Intelligent Provisioning reinstall every time I press F10 on my ML350 Gen10 server?

To resolve the issue, ensure the F10 prompt is enabled in the server security settings. If iLO FIPS mode is active, disable it temporarily as it may prevent IP from launching. Additionally, perform an offline installation of Intelligent Provisioning using the latest recovery media and update firmware from a local source to avoid dependency issues. [community thread]

Why do the fans continue to run after shutting down the DL380 Gen11 server?

If the fans remain operational after the server is powered off, try reseating the fans and ensuring proper airflow around the unit. Additionally, check for any loose internal components, tangled cables, or missing drive blanks that could affect the cooling system. If the issue persists, review the front panel LEDs for any warning indicators. [community thread]

What can I do about loud fan noise on ML350 Gen11 servers?

If your ML350 Gen11 servers are experiencing high fan speeds, ensure that all drivers, firmware, and BIOS are updated to the latest versions. If the issue persists, consider checking the server's thermal settings or consulting the manufacturer's documentation for fan and thermal management solutions. [community thread]

What should I do if my HPE DL380 Gen10 server shows a critical fault and fails to power on?

If your server displays a critical fault and does not complete the power-on self-test (POST), first disconnect the power supplies for at least 60 seconds before reconnecting them. Ensure that the power supplies are properly seated and check their LED indicators. If the issue persists, reduce the server to a minimal hardware configuration and consult the Integrated Management Log for any additional power-related errors. [community thread]

Can I install third-party SATA hard drives in the HPE Proliant ML110 Gen11 and do I need a caddy?

The HPE Proliant ML110 Gen11 supports only 3.5-inch LFF drives, and you will need a compatible caddy for each hard drive. For optimal performance, consult the server's specifications for a list of supported drives and reach out to your reseller for recommendations. [community thread]

What should I do if I encounter an 'invalid signature' error when flashing the firmware on my HP DL380 Gen10 server?

To resolve the 'invalid signature' error, first ensure you download the firmware update directly from HPE's official site and verify the checksum of the new file. Run the update as an Administrator, and if the issue persists, consider using the iLO Web GUI or HPE Smart Update Manager for the update, as these methods can bypass signature validation problems. [community thread]

What should I do if I see a warning about unrecoverable media errors on my server's drives?

This warning indicates that errors were detected during a previous scan, but they can be resolved automatically when the affected sectors are overwritten. To check the status of each disk without impacting the RAID volumes, you can use the command 'ctrl slot=0 pd all show' to review the health of the drives. [community thread]

How can I remove or disable the VID drive on a DL560 Gen10 server?

To disable the VID drive, update the iLO firmware to the latest version, then navigate to Intelligent Provisioning, go to BIOS/Platform Configuration (RBSU), select USB options, and disable the Virtual Install Disk. [community thread]

Why are the fans on my DL380 Gen10 server running loudly and inconsistently?

Loud and inconsistent fan speeds can be caused by various factors, including outdated firmware. Ensure that both the iLO and BIOS are updated to the latest versions, and consider adjusting the BIOS cooling settings to 'Optimal cooling' and the workload profile to 'Max Performance' for better management of fan speeds. [community thread]

What should I do if all LEDs on my HPE DL380 Gen10 are flashing and the server won't start?

You may need to clear the NVRAM using the System Maintenance Switch to resolve the issue. After doing this, check the iLO settings, as they may have reverted to default values. [community thread]

What is the part number for the 3.5' drive caddy compatible with the Proliant ML350 Gen11?

The part number for the LFF 3.5' drive caddy for the Proliant ML350 Gen11 is P47216-B21. Additionally, if upgrading the 2nd or 3rd LFF drive cage, you will need the embedded SATA cable kit, part number P47225-B21. [community thread]

Why are some IPMI sensor readings showing as N/A on my ML30 Gen10 server?

The presence of N/A readings for certain IPMI sensors typically indicates that those sensors are not supported or not reporting data correctly. You can check actual sensor values through the iLO web interface or consider installing HPE AMS or agents for better monitoring, although compatibility may vary with different operating systems. [community thread]

What is the best method to update firmware on an HPE ProLiant DL360 Gen12 server?

To effectively update the firmware on your HPE ProLiant DL360 Gen12, use the HPE Service Pack for ProLiant (SPP) ISO via the iLO Virtual Media. Download the SPP ISO, access the iLO web interface, mount the ISO as virtual media, reboot the server, and follow the HPE SUM update process. If you encounter connectivity issues during provisioning, check your network and DNS settings. [community thread]

How can I enable the write cache on the HPE Smart Array P408i-p SR Gen10 after a foreign configuration import?

To enable the write cache, ensure that the logical drive's write policy is set to 'Write Back' and that the drive write cache policy is enabled or set to default in the SSA. Additionally, if SSD Smart Path is active, consider disabling it to allow the cache to be utilized. [community thread]

Are 30.72TB NVMe U.2 SSDs compatible with the DL380 Gen10 server?

Yes, the DL380 Gen10 server supports 15.36TB NVMe SSDs, and it is likely that 30.72TB NVMe U.2 SSDs will also be compatible. For confirmation, refer to the server's specifications regarding maximum internal storage and supported drives. [community thread]

How can I monitor the SSD rebuilding status in iLO 5 after replacing a drive?

iLO 5 does not provide information on the rebuild status of SSDs. To check or monitor the rebuild status, you will need to use HPE Smart Storage Administrator or HPE MegaRAID Storage Administrator. [community thread]

Can I add disks to an existing RAID 10 volume on a ProLiant DL380 Gen11 server?

RAID 10 volumes on MR controllers cannot be expanded by adding additional disks. To increase capacity, you will need to back up your data, delete the existing array, create a new array with all drives, and then restore your backup. [community thread]

What should I do if I encounter a 338 API RESTful error on my HP DL380 Gen10 server?

The 338 API RESTful error indicates a communication issue between the host firmware and iLO. To resolve this, first ensure that your system ROM and iLO firmware are updated, then confirm the server boots correctly before enabling features like TPM and Secure Boot. If Secure Boot is not enabled, the server will continue to operate normally, but some security features may be limited without a Trusted Platform Module. [community thread]

Why is the 'Expand' option missing for my logical drive when multiple logical drives are configured?

The 'Expand' function is only available when there is a single logical drive configured per array. Once more than one logical drive is created, the option to expand becomes unavailable, which appears to be a limitation of the controller. [community thread]

What should I do if the Gen11 Intelligent Provisioning cannot connect to the firmware repository?

To resolve this issue, download the Intelligent Provisioning Recovery Media for Gen11 servers and update it by booting from the ISO image. Ensure that your network settings and proxy configurations are correct, as these can affect connectivity. [community thread]

What should I do if a DIMM slot on my HPE Proliant DL380 Gen 11 server is damaged?

The memory must be installed according to specific population rules, and leaving a damaged slot empty may not be supported by the motherboard. It is advisable to contact HPE Support for assistance and potentially arrange for a motherboard replacement. [community thread]

What could cause the fans on a ProLiant DL380 Gen10 to be noisy despite no reported issues in iLO?

Noisy fans can indicate a perceived cooling risk, often due to factors such as a malfunctioning thermal sensor, firmware issues, or airflow obstructions like dust. To address this, check the iLO logs for any relevant messages, ensure firmware is up to date, and inspect for dust buildup or misaligned components. [community thread]

What should I do if my HPE Proliant DL380 Gen10 hangs during reboot?

Check the Integrated Management Logs in the iLO for any error events that could explain the issue. You may need to perform a minimum configuration by removing and reinstalling components to identify the source of the problem. [community thread]

Why are the drives in my HPE DL380 Gen11 server not being recognized?

Ensure that the drives are properly connected to the correct storage controller and check if they are detected in the server's BIOS or management interface. If the drives are still not recognized, consider verifying compatibility with the server model and updating the firmware. [community thread]

What should I do if my DL380 Gen10 server displays a 'switching console to alternate' message and the VGA monitor remains dark?

To troubleshoot this issue, first access the iLO web interface and launch the Integrated Remote Console to monitor the boot sequence for any errors. If the local VGA remains unresponsive, consider resetting the iLO settings and performing a full AC power cycle, ensuring to check the BIOS settings for console redirection and iLO functionality. [community thread]

What should I do if my HPE Proliant DL360 G10 experiences a critical fault and shuts down unexpectedly?

After updating the Service Pack for ProLiant (SPP), monitor the server's performance. If the issue persists, consider opening a support case and include the Advanced Health Status (AHS) logs for further analysis. [community thread]

Is the standard cooler sufficient for upgrading the CPU in an HP ProLiant DL360 Gen10 to a higher TDP model?

The standard cooler is generally adequate for CPUs with a TDP up to 125W, such as the Xeon Gold 5218 and Xeon Silver 4216. However, for optimal thermal performance and reduced fan noise, it is advisable to use a high-performance cooler for the 125W CPU. [community thread]

Why are the fans running at high speeds after installing an NVME SSD in a DL20 Gen10 server?

High fan speeds can occur when the server detects components that may not be fully supported. Ensure that the NVME SSD installed is compatible with the DL20 Gen10 server, as using unsupported hardware can lead to increased fan activity to manage thermal conditions. [community thread]

Why is my HPE ProLiant ML110 Gen11 server not recognizing the installed hard drive?

Ensure that the hard drive is compatible with the server model and check if all firmware and BIOS updates are correctly applied. Additionally, verify that the drive is properly connected and consider consulting the troubleshooting documentation for further guidance. [community thread]

Can I install an RTX 3090 in a DL380 Gen10 server?

The DL380 Gen10 server does not officially support the RTX 3090, and using unsupported hardware may lead to compatibility issues. It is recommended to use only the GPUs listed in the server's quickspecs for optimal performance and reliability. [community thread]

What should I do if the firmware update fails on a DL385 Gen11 server?

Verify the method used for the firmware update, whether through the operating system, iLO web interface, or HPE Service Pack for Proliant (SPP). If issues persist, check for specific resolutions related to the components involved, as some may still be under investigation. [community thread]

Why does iLO 5 stop responding to SNMP requests after some time?

The issue may stem from compatibility problems with third-party monitoring software like Zabbix, which has not been officially tested with HPE iLO. Users have reported that iLO stops responding after a period, requiring a reset to restore functionality. [community thread]

Can I expand a RAID 10 array on a Megaraid 416i-p controller?

It is not possible to expand a RAID 10 array using a Megaraid 416i-p controller, as confirmed by HP. You may need to consider creating a new array with additional disks or migrating to a different RAID level. [community thread]

What should I do if my ProLiant DL360 Gen10 won't power on after a firmware update failure?

If the server is unresponsive and only shows a flashing power light, check the ILO console for any error messages in the IML log. You may also try updating the ILO, BIOS, and SPS directly from the ILO interface. If these steps do not resolve the issue, it is advisable to contact HPE support for further assistance. [community thread]

How can I create a virtual disk on a DL360 Gen10 Plus with an MR416i controller using Redfish?

Currently, the MR-series controllers do not support Redfish write operations such as creating volumes. Users must utilize a StorCLI script from a pre-boot OS for automated deployment until firmware updates enable these features. [community thread]

What type of screws are needed to mount the rear LFF cage on a DL380 Gen10 server?

To secure the rear LFF cage (part number 867216-001) on a DL380 Gen10, you will typically need M3 x 5mm pan-head screws. These screws are usually included in the kit, but if they are missing, you can use standard M3 screws temporarily or order replacements from HPE's spare parts. [community thread]

What should I do if I encounter memory errors after upgrading the CPU in my DL380 Gen11 server?

Memory errors after a CPU upgrade may be due to incorrect DIMM slot configuration or BIOS settings. Ensure that the memory modules are installed in the correct slots as per the server's guidelines, update the BIOS and firmware to the latest versions, and reset the BIOS to default settings. If issues persist, consider running diagnostics to identify specific memory slot errors. [community thread]

How can I disable the Virtual Install Disk (VID) on a ProLiant DL360 Gen10 server?

The Virtual Install Disk (VID) option has been removed from the BIOS settings in ProLiant Gen10 servers, so it cannot be disabled through the usual configuration menus. If the VID is still appearing in your operating system, it may be a remnant from previous Intelligent Provisioning and may not be removable. [community thread]

What power cable do I need for an Nvidia 6000 graphics card in a DL380 Gen10 server?

To power an Nvidia 6000 graphics card in a DL380 Gen10, you typically need the 871830-B21 cable kit, which is designed for GPU configurations. However, it's important to confirm the specific GPU model and its power connector requirements, as well as ensure that your server has the appropriate GPU riser and power headers. [community thread]

How can I add more drives to an ML350 Gen10 server?

To increase the number of drives in an ML350 Gen10, you will need the appropriate drive cage (765756-001) and cables (876491-001 and 876496-001). Additionally, consider installing a SAS Expander (876907-001) or a compatible storage controller based on your needs; consulting with a reseller for confirmation is recommended. [community thread]

Why are the 18TB drives not detected in the DL380 Gen10 server?

First, confirm that the 18TB P37664-B21 drives are compatible with the p816i-a controller and that the firmware is up to date. Check all physical connections, including data and power cables, and ensure the port discovery mode is set to Universal Backplane Management. If the issue persists, testing with different drives may help identify if the problem lies with the 18TB drives. [community thread]

What additional components are needed to install the NS204i-u boot device in a DL380 Gen11 server?

The NS204i-u boot device requires a specific bracket and a cable kit for installation, which are not included with the device itself. It is advisable to consult the HPE ProLiant DL380 Gen11 Server User Guide for detailed installation instructions and to verify the necessary parts with an HPE reseller. [community thread]

Is a storage controller battery pack necessary for a DL360 G11 with SSDs configured in RAID 1 and RAID 10?

A battery pack for the HPE MR408i-o storage controller is optional and can enhance performance by providing Flash-Backed Write Cache. The standard battery pack comes with a 145mm cable, and if a longer cable is needed, an extension may be required. [community thread]

What does the Input Power Loss error mean on a DL380 Gen10 server?

The Input Power Loss error typically indicates an external power issue rather than a failure of the power supply unit (PSU). This could be due to problems with the power source, such as a loose cable, PDU, or UPS. If the server is functioning normally and both PSUs are healthy, no replacement is necessary; however, it's advisable to investigate the power source if the issue recurs. [community thread]

Do I need additional hardware to install 3 M.2 NVMe SSDs in a DL360 Gen10 server?

Yes, to use three M.2 22110 NVMe SSDs in a DL360 Gen10, you will need to acquire an M.2 riser kit, specifically part number 867978-B21, which supports the necessary connections. [community thread]

What is the recommended upgrade path for the BIOS and iLO on a ProLiant DL360 Gen10 server?

It is advisable to use the latest Service Pack for ProLiant (SPP) to update all firmware and software to the most recent compatible versions in one go. Alternatively, you can update the iLO firmware and System ROM separately, but it is generally recommended to incrementally upgrade by two versions at a time for both components. [community thread]

What should I do if Intelligent Provisioning on my DL360 Gen11 server is not loading?

To resolve issues with Intelligent Provisioning not loading, ensure you download the correct Recovery ISO for your specific server model from the HPE Support site and verify its checksum after downloading. Additionally, consider updating the system ROM or iLO firmware, as outdated firmware can lead to mounting problems with virtual media or USB. [community thread]

What should I do if the Agentless Management Service is not detected on my DL380 Gen10 server running ESXi 7.0.2?

Ensure that you are using the HPE custom ESXi image, as it includes the necessary AMS and iLO drivers. If the issue persists, verify the installation of the AMS package through the ESXi management interface and consider reverting to an earlier version of ESXi, such as 6.7, where AMS is recognized. [community thread]

How can I upgrade the BIOS on my HPE DL380 Gen10 servers?

To upgrade the BIOS on HPE DL380 Gen10 servers, download the latest System ROM firmware from the HPE Support Center under Drivers & Software. You can install it using either the Windows or Linux method, or by using the System ROM Flash Binary for an OS-independent installation. Alternatively, you can download the latest Service Pack for ProLiant (SPP) ISO, create a bootable USB, and use Smart Update Manager to update the BIOS for both servers. [community thread]

What should I do if my HPE ML350 Gen10 server shows 'No drives found' after a firmware update?

This issue often arises when the Smart Array controller firmware is outdated after upgrading iLO and System ROM. To resolve it, ensure that the controller firmware is updated in stages, starting with an intermediate version before moving to the latest. Additionally, check the compatibility of your firmware versions, clear any failed firmware uploads in the iLO repository, and reboot the server to allow the controller to reinitialize. [community thread]

How can I revert the firmware on a DL360 Gen10 server after an update caused it to hang during boot?

To downgrade the firmware, utilize the 'Force' option with the appropriate SPP.iso image for the version you wish to revert to. It's important to ensure that the downgrade is necessary before proceeding, as it is generally not recommended. [community thread]

Does the onboard SATA of the DL380 Gen10 support hotswap functionality?

The onboard SATA ports do not support hotswap; drives must be connected while the server is powered off. Additionally, it is recommended to use HPE-approved components for optimal performance. [community thread]

What should I do if my DL360 Gen11 or DL380 Gen11 server experiences a PSOD when resetting iLo6 v1.60?

To address the PSOD issue, try removing any installed hardware and boot the server with minimal configuration. Ensure all firmware and device drivers are updated to the latest versions. If the problem persists, consider opening a support case with HPE for further assistance. [community thread]

How can I restore IPv4 access to my iLO5 after upgrading to version 3.05?

Verify that the IPv4 address is correctly configured using the HPE Lights-Out Online Configuration Utility, which can be installed on your server. If the address is set correctly, try restarting the iLO management controller, as the firmware upgrade may have reset settings to defaults. [community thread]

Are P19823-B21 / P20597-001 drives compatible with the HPE MR408i-o Gen11 x8 storage controller in the DL360 Gen11 server?

The P19823-B21 / P20597-001 NVMe drives are not officially listed as compatible with the HPE MR408i-o Gen11 controller or the DL360 Gen11 server. It is advisable to use drives that are specifically documented for the Gen11 to ensure compatibility. [community thread]

What should I do if I encounter a PropertyValueFormatError when changing the DNS name on a DL360 Gen11 server using ilorest?

This error may be due to the format of the hostname, particularly if it includes a dot. Check the RESTful Interface Tool User Guide for guidance on valid hostname formats and consider using a different naming convention. [community thread]

Why is my ML350 Gen 11 server's fan making loud noises after shutdown and when using a third-party NVME PCIe card?

The loud fan noise may occur because third-party components can disrupt the thermal monitoring system, leading the server to increase fan speed to prevent overheating. To determine if the issue is related to the PCIe slot or the third-party card, consider using an HPE-approved component and check if the problem persists. [community thread]

What components are needed to use NVMe SSDs in a DL325 Gen10 Plus server?

To utilize NVMe SSDs in a DL325 Gen10 Plus server, you will need the appropriate NVMe Enablement Kit along with compatible drive bays. Ensure that your server's configuration supports NVMe by checking the installed components and their compatibility. [community thread]

How can I resolve the Persistent Memory error 582 on my DL360 Gen10 server?

To address the Persistent Memory error 582, consider swapping the BIOS with the redundant BIOS and re-flashing the BIOS. Ensure that all system firmware, including the System ROM BIOS, is updated using the Service Pack for ProLiant. Additionally, verify that your server's hardware configuration meets the requirements for Intel Optane Persistent Memory, as the DL360 Gen10 may not support it. [community thread]

Can I replace SFF drives with SSDs in the HP ProLiant ML30 Gen11 server?

Yes, the HP ProLiant ML30 Gen11 allows for the installation of SSDs in SFF (2.5") drive bays. If your server has LFF (3.5") bays, you will need a conversion kit to use SFF SSDs. Ensure you use compatible HPE 2.5" drive carriers for proper installation. [community thread]

What boot device is compatible with the DL345 Gen11 server?

For the DL345 Gen11 server, the recommended boot device is the NS204-i v2 (P78279-B21) when using a 5th Gen AMD Epyc CPU. Additionally, you can refer to the server's QuickSpecs for detailed information on boot controllers and cabling requirements. [community thread]

What should I do if the iLO port on my ML30 Gen11 is not functioning with a USB RJ45 adapter?

Try using the dedicated iLO port located at the back of the server or configure iLO to share a host network interface card (NIC). Additionally, ensure that both the iLO firmware and system BIOS are updated, as newer versions may resolve connectivity issues. [community thread]

Why is my Proliant DL360 Gen11 server's fan running at a high speed despite low temperatures?

If the fan speed is consistently high even with optimal settings in ILO6, it may be due to firmware settings or a need for a BIOS update. Check for any available updates and ensure that the server's thermal settings are correctly configured. [community thread]

What is the correct tray name for adding 3.5 inch hard drives to a ProLiant DL380 Gen10 server?

When expanding storage in a ProLiant DL380 Gen10, it's important to note that there are limitations when using both 2.5 inch and 3.5 inch drives together. For specific details, consult the QuickSpecs documentation, particularly pages 13, 38-40, and 52. [community thread]

What does the error code 02h mean on a DL360 Gen10 server during startup?

The 02h error code indicates a processor-related issue detected during the power-on self-test (POST). To resolve this, ensure that the firmware for BIOS and iLO is updated, set the workload profiles to High-Performance Compute (HPC) in RBSU, and check the cooling system for proper airflow and functioning fans. If the problem continues, consider exporting the ASH log for further assistance from support. [community thread]

Why do my SATA drives work in a PC but fail to create a RAID in my server?

This issue occurs because the Smart Array controller has marked the drives as RAID-ineligible due to previous errors, which cannot be reset through standard methods. While the drives can still function in non-RAID configurations or other systems, they cannot be used in RAID setups on the affected controller. To use RAID, you will need to replace the flagged drives. [community thread]

What should I do if I encounter an error when creating a RAID5 array on a ProLiant DL360 Gen10 server?

First, ensure that all firmware is up to date on the controllers and verify that each controller has a cache module installed. If the issue persists, check if CBE encryption is enabled; disabling it may resolve the problem and allow you to create the RAID5 array successfully. [community thread]

How can I successfully install two Nvidia L40S GPUs in a DL380 Gen11 server?

To install two L40S GPUs, ensure your server is the correct variant with the appropriate risers, power cables, and cooling. Verify that the secondary and tertiary risers are compatible with dual GPU setups and check for any physical obstructions in the chassis that may hinder installation. If issues persist, consult HPE Support for a detailed installation guide specific to your chassis model. [community thread]

What should I do if my HP Proliant Server ML110 Gen11 shows a 'no controllers found' error?

Ensure that the storage controller is properly installed and connected. If the issue persists, consult the user guide for instructions on preparing the server for storage controller installation and check the network operating system installation guide for further troubleshooting steps. [community thread]

Why are multiple characters being entered instead of a single character in the HTML5 console of my server?

This issue may be related to the specific remote access software being used, as some users have reported that the problem does not occur with alternatives like TeamViewer. Ensure that your iLO5 firmware is updated, and consider testing with different remote access tools to identify the source of the problem. [community thread]

Why are only 10 out of 12 disks recognized in my DL380 Gen10 server?

Ensure that the drives in the bottom right slots are properly seated and compatible with the server. Check the cabling from the controller to the drive backplane and reseat it if necessary. Additionally, try removing any M.2 drives to see if that affects the detection of the remaining disks. [community thread]

Do DL380 Gen11 and Gen12 servers support SNMPv2?

Yes, both the DL380 Gen11 and Gen12 servers support SNMPv2 for monitoring and trap forwarding, primarily for compatibility purposes. While SNMPv2 is available, it is recommended to use SNMPv3 for secure management. [community thread]

What should I do if I cannot access the iLo web interface on my ProLiant DL 360 Gen 10 server?

If you are unable to log in to the iLo web interface and receive a timeout error, consider resetting the iLo from the command line. Additionally, check for any warnings related to the embedded flash and follow troubleshooting steps, such as updating the firmware or formatting the NAND, but if issues persist, it may be necessary to seek professional support. [community thread]

What should I do if my HPE DL320 Gen11 server displays 'no controller found'?

This message usually indicates an issue with the storage controller or its settings. Check if the controller is properly installed and enabled in the BIOS/UEFI, ensure that the firmware is up to date, and use the appropriate tools like HPE MR Storage Administrator for configuration. [community thread]

Why does my HPE ProLiant DL380 Gen10 show 256GB of RAM installed but only 128GB usable?

The issue may arise from improper memory configuration, as the DL380 Gen10 requires specific DIMM population for dual CPUs. To utilize the full 256GB, ensure that you have the correct number of DIMMs installed, such as using 4x32GB instead of 2x64GB. [community thread]

What should I do if Fan 3 on my HPe Proliant DL20 Gen11 is stuck at 60% and making noise?

First, check the firmware versions for iLO and System ROM to ensure they are all compatible and updated. Inspect Fan 3 for any physical issues, such as obstructions or loose connections, and consider running diagnostic tests to assess its functionality. If the problem persists after these checks, the fan may need to be replaced or further investigation into the backplane or thermal controller may be necessary. [community thread]

Is the NVIDIA A100 80GB GPU compatible with the HPE ProLiant DL380 Gen12 server?

The NVIDIA A100 80GB GPU is not supported on the HPE ProLiant DL380 Gen12 server. It is advisable to refer to the official documentation for a list of compatible GPUs, such as the NVIDIA H200 NVL and H100 NVL models. [community thread]

Why can't I configure non-HPE drives in RAID on my ML350 Gen10 server with a P408i-a SR controller?

The P408i-a SR controller may not support non-HPE drives for RAID configurations, leading to errors during setup. It's advisable to verify that the drives are recognized in HPE Smart Storage Administrator and to use HPE-branded drives for optimal compatibility. [community thread]

What SAS expander card should I use for the DL380 Gen10 Plus server?

For the DL380 Gen10 Plus, you can consider using the HPE Smart Array P408i-p SR Gen10 or the HPE Smart Array P816i-a SR Gen10 controllers. Additionally, you can find the SAS expander details at HPE's PartSurfer website. [community thread]

Why is one DL 380 Gen10 server's fan running at a high speed while another is normal?

This discrepancy in fan speeds may be due to a configuration issue. It is advisable to check the server settings and consult relevant community discussions for potential solutions. [community thread]

Why is the performance of my HPE Smart Array P408i-a SR Gen10 poor with certain RAID configurations?

The subpar performance in your RAID5 and RAID1 setups is likely due to the absence of caching, as the HPE Smart Array P408i-a SR Gen10 needs a physical cache module and a valid license to enable write-back caching. Without these, the system operates in write-through mode, which significantly slows down write operations. [community thread]

What should I do if I see security log changes and a default SSL certificate warning on my HPE ProLiant DL 380 Gen11?

The log message about the Security Configuration PCR Measurements indicates a change due to a firmware or configuration update, which is normal unless it happens repeatedly without changes. For the SSL certificate warning, it is advisable to replace the default self-signed certificate with a trusted one by generating a CSR and getting it signed by your internal CA or importing a valid certificate. [community thread]

What should I do if my DL380 Gen10 server shows no drives detected after upgrading ILO 5?

To resolve the issue, update the Smart Array P408i-a controller firmware to the latest version. If the problem continues after the update, consider contacting support for further assistance. [community thread]

Why are the SSDs not being recognized in my HPE DL380 Gen10 server?

The issue may stem from a failed cache module on the Smart Array controller, which can prevent SSD detection. To troubleshoot, check the cache status using ssacli, replace the cache module if necessary, and ensure that the SSDs are properly seated and compatible. [community thread]

Is a cache cable required for the P408e card in the ML110 Gen10 server?

The cache cable is necessary only if a Smart Array P-Series controller is installed, as this server supports the installation of a FBWC module in that scenario. If you are using a different RAID controller for local disks, the cache cable may not be needed. [community thread]

What should I do if the power supplies of my DL380 Gen10 server are outputting only 6.7 volts instead of 12 volts?

First, ensure the server is configured with minimal hardware to rule out other issues. Test each power supply individually and check the dip switch settings on the motherboard. If the problem persists, consider logging a support request and verifying the compatibility of the power supplies. [community thread]

Why is my Proliant DL360 Gen10 server's fan running at high speeds?

High fan speeds may occur due to outdated firmware or temperature reporting issues. To resolve this, ensure that the Innovation Engine Firmware is updated to version 0.2.2.0 or later, and if the issue persists, try rebooting the server to normalize fan speeds. [community thread]

Can I replace a failing 600GB 15K SAS drive in a DL360 Gen10 with a different model?

Yes, you can replace the failing 600GB 15K SAS drive with either the 872477-B21 or 872479-B21 models, as they are compatible with the DL360 Gen10 server. However, if you choose the 1.2TB drive, note that the additional capacity will not be utilized in the existing RAID array. [community thread]

What does the ControllerPreviousError message mean on a DL360 Gen11 server?

The ControllerPreviousError indicates that the storage controller experienced an issue in the past, but it is not currently active. To address this, ensure that the controller firmware is updated, check the Integrated Management Log for similar entries, and monitor for any recurrence of the error. Running diagnostics with HPE Smart Storage Administrator may also help assess the controller's health. [community thread]

What firmware versions should I use for an HPE DL380 Gen10 server running VMware ESXi 8.0 Update 3?

For optimal performance and compatibility with ESXi 8.0 U3, it is recommended to use the Service Pack for ProLiant (SPP) 2025.11. This package includes validated firmware for all critical components, and you can view the specific versions by loading the SPP ISO into Smart Update Manager (SUM), which will display the recommended firmware for each part. [community thread]

Why is the HPE NS204i-u controller not detected during the Windows Server 2022 installation on a DL380 Gen12?

The HPE NS204i-u is an NVMe OS-boot device, which may not be recognized by Intelligent Provisioning due to its optimization for traditional Smart Array controllers. To successfully install Windows Server 2022, it is recommended to use a Microsoft ISO, as this method allows the OS to recognize the NS204i-u volume directly. [community thread]

Why is my Mellanox Connect-X 6 DX network card only showing as x8 instead of x16 in a DL360 Gen10 server?

The reduced link width from x16 to x8 may not be due to intentional bifurcation but rather a result of PCIe link training issues. Ensure that the correct risers are installed and check the BIOS settings for PCIe bifurcation options. Additionally, verify compatibility between the network card and the specific PCIe slot, as different slots may be attached to different CPUs. [community thread]

How can I boot my DL325 Gen11 server from an ISO using iLO virtual media?

To boot from an ISO via iLO, first connect the ISO as a virtual CD in the iLO interface and ensure it shows as 'Connected.' Perform a full power-off and then power-on the server to allow the virtual media to be recognized during the boot process. If the virtual CD does not appear in the boot menu, check the UEFI settings and ensure that 'Boot from Removable Media' is enabled. [community thread]

Is my data safe if I replace the Smart Storage Battery on my HPE ProLiant DL380 Gen10?

Yes, your data should remain safe when you change the Smart Storage Battery. However, it is advisable to ensure that you have a backup of your data before proceeding with the replacement. [community thread]

What is the difference between RAID configuration in F9 System Utilities and F10 Intelligent Provisioning on the HPE ProLiant DL360 Gen10 Plus?

The RAID setup in F9 System Utilities is typically associated with hardware RAID, while F10 Intelligent Provisioning may offer options for software RAID. It's important to consult the server's documentation for specific details on RAID types and configurations. [community thread]

Why is my RAID controller not detected during installation on my ProLiant DL360 Gen10 Plus?

The error indicates that the system cannot find a supported Smart Array SR controller because your server is equipped with an MR controller instead. You can configure RAID using the F9 option during boot, and ensure you are using the latest version of Intelligent Provisioning, which includes support for the MR controller. [community thread]

What should I do if the HPE Agentless Management Bundle installation fails on my Gen10 server?

Verify that all prerequisite versions match the expected upgrade requirements, as discrepancies can lead to installation failures. Additionally, check for any leftover files or cached data from previous upgrade attempts that might cause issues. If problems persist, consider running the installer in verbose mode for more detailed error messages or consult HPE support for assistance. [community thread]

Why can't I connect to my iLO 5 after upgrading to firmware 3.06 from outside my network?

There may be known communication issues with iLO firmware versions 3.05 and 3.06, particularly when using a Shared Network Port (SNP). If you're using a dedicated port and still facing problems, consider downgrading the firmware back to 3.01 as a potential solution. [community thread]

What should I do if my DL385 Gen11 server is experiencing high fan speeds?

To address high fan speeds, ensure that all firmware is updated using the latest Service Pack for ProLiant (SPP). Additionally, check the server profile settings in the RBSU/BIOS menu to optimize performance. [community thread]

What should I do if my HPE Gen11 servers using VROC RAID are experiencing repeated port failures?

To address recurring VROC port failures on HPE Gen11 servers, ensure that all firmware, BIOS, and VROC drivers are updated to the latest versions. Check hardware compatibility, monitor the health of the RAID controller, and examine disk connections for issues. If problems persist, consider testing different RAID configurations or engaging HPE support for further assistance. [community thread]

What does it mean if all LEDs on an HPE DL380 Gen10 are flashing when powered on?

Flashing LEDs typically indicate a critical server failure, which may be related to a faulty system board. It's advisable to check the iLO IML log for detailed error information and consult the user guide for insights on the front panel indicators. [community thread]

What do I need to add a second disk cage to an HP DL380 Gen10 server?

To successfully add a second disk cage, you will require additional components such as a SAS Expander for each extra cage, as each cage needs two connections. For specific options and installation instructions, refer to the HPE documentation. [community thread]

What should I do if my RAID controller shows 'N/A' after a firmware update on a ProLiant DL360 Gen10 server?

If your RAID controller is not recognized and shows 'N/A' in iLO after a firmware update, first check if the controller is detected in the BIOS. If it is not visible there, you may need to re-seat the controller or check for hardware issues, as it was previously detected before the update. [community thread]

Where can I find a COV for ProLiant DL360 Gen10 or DL380 Gen10 servers?

If you bought the servers directly from HPE, it's best to reach out to HPE's sales or customer support for assistance with obtaining a COV. [community thread]

How can I use all 12 drive bays in an HP DL180 Gen10 server with a P408i-a controller?

The P408i-a controller only supports a maximum of 8 drives, so to utilize all 12 bays, you will need to replace it with a P416i controller. Additionally, ensure that the drives connected to the onboard controller are compatible, as the onboard S100i only supports SATA drives. [community thread]

What types of hard drives can be installed in the HPE ProLiant DL380 Gen11 server's SFF bays, and does it come with NVMe SSDs?

The SFF drive bays in the HPE ProLiant DL380 Gen11 server can accommodate either SAS or SATA drives, depending on the specific configuration of the backplane and controller. Additionally, the server is equipped with two 960GB NVMe SSDs connected to the NS204i-u controller. [community thread]

What additional hardware is needed to install an HP Nvidia Tesla P100 GPU in an HP DL380 Gen10 server?

The HP Nvidia Tesla P100 GPU with part numbers 868199-001 and 86585-001 is not compatible with the HP DL380 Gen10 server. For proper installation, you should use the supported HPE NVIDIA Tesla P100 12GB Module with part number 877646-001. [community thread]

Why are my disks not showing up after installing the HPE Dual M.2 SATA SSD Enablement Option on my DL360 Gen10 server?

The disks may not be recognized because the server's RAID controller is managing the standard SATA ports, which can prevent them from being enumerated by the BIOS or operating system. To resolve this, connect the enablement card to the Optical/SATA Port 5, as this port is designed to bypass the RAID controller and allow detection of the attached disks. [community thread]

Where can I find the meanings of POST Code messages for a DL360 Gen10 server?

While there is documentation available for specific POST error codes, a comprehensive guide for generic POST codes displayed during the startup sequence is not readily available. For detailed troubleshooting, consider consulting the server's manual or reaching out to technical support. [community thread]

Is the Intel E610-IT4 network adapter compatible with the Proliant ML350 Gen11 server?

The recommended network adapter for the Proliant ML350 Gen11 is the Intel E810-XXVDA2. However, if you are considering the E610-IT4, please verify its compatibility with your specific server setup, as it may support different speed configurations. [community thread]

What should I do if my firmware update for the HPE Eth 10/25Gb 2p 631FLR-SFP28 adapter fails on a DL380 Gen10 server?

If you encounter errors during the firmware update, consider using an offline update method. Refer to official documentation or instructional videos for guidance on performing the update successfully. [community thread]

How can I find the pinout diagram for the power cable of the DL360 Gen10 backplane?

The pinout voltage details for the power cable are not provided in the user or maintenance guides for the DL360 Gen10. You may need to consult with technical support or community forums for assistance. [community thread]

What should I do if my M.2 drive is not detected in a DL385 Gen10 server?

First, ensure that the M.2 drive is compatible with the server's slot type (NVMe or SATA). Check the BIOS settings to confirm that the slot is enabled and that the storage mode is correctly configured. Additionally, reseat the drive, verify any lane conflicts, and ensure that the appropriate drivers are installed. [community thread]

Why does my DL360 Gen10 server shut down unexpectedly?

Unexpected shutdowns may occur due to firmware issues, particularly if the system ROM firmware is outdated. Check the Integrated Management Logs for any related errors, and consider updating the firmware to resolve potential bugs. [community thread]

How can I apply updated Secure Boot certificates on my HP Proliant DL380 Gen10 servers?

To apply the updated Secure Boot certificates, first ensure that your server's BIOS is updated to the latest version. After updating, reboot the server to implement the changes. Additionally, enable the UEFI Secure Boot setting in the UEFI System Utilities if it is currently disabled. [community thread]

Are PCIe Gen 5 U.3 NVMe drives compatible with the HPE ProLiant DL365 Gen11?

The HPE ProLiant DL365 Gen11 primarily supports PCIe Gen 4 NVMe drives, and there is no official documentation confirming compatibility with PCIe Gen 5 U.3 NVMe drives. While Gen 5 drives may fit in the slots, they might not function properly without specific motherboard and firmware support. It is advisable to check the latest firmware updates and HPE's official resources for any changes regarding compatibility. [community thread]

What should I do if my HPE ML350 Gen10 shows a POST 453 error when using Intel Optane Persistent Memory?

First, ensure that your server is updated with the latest HPE Service Pack for ProLiant and the firmware package for HPE Persistent Memory. If the error persists, test the same PMem module in a supported server model, such as the DL360 or DL380, to confirm if the ML350 Gen10 supports the Optane Persistent Memory. [community thread]

What should I do if the Bit Error Test fails on my DL380 Gen12 server?

First, ensure that your CPU and DIMM are compatible with the server model. Next, update the BIOS to the latest version, as this can fix potential false failures. If the issue persists, try testing the DIMM in a different slot or replace it with a known good DIMM to determine if the original is faulty. [community thread]

Why is my BCM57414 card not functioning in Windows Server 2022 on a DL360 Gen10?

Ensure that the BCM57414 card is compatible with your server SKU. It's advisable to update the system firmware and drivers using the Service Pack for ProLiant (SPP) to address any potential firmware mismatches. Additionally, verify that the riser, server, and network card are all compatible. [community thread]

What should I do if my iLO7 Mail Alert feature is not sending emails?

First, verify that your iLO can connect to the SMTP server on port 587 using telnet. Ensure that the 'SMTP Secure Connection (TLS)' option is enabled and that your username and password are correct. Additionally, check your SMTP server settings, firewall rules, and DNS resolution to confirm that there are no blocks preventing the connection. [community thread]

How can I update the iLO firmware on a DL360 Gen10 server using CentOS 7?

To update the iLO firmware from version 1.20 to 3.09, ensure you have the correct RPM file and that you are using the management processor credentials when prompted. It is advisable to perform firmware updates incrementally, starting from the minimum supported version. [community thread]

Why is my rail kit not aligning with my DL325 Gen10 Plus server chassis?

The rail kit may not be compatible due to differences between the generations of the DL325 Gen10 Plus servers. The P18544-B21 rail kit is designed for the Gen10 Plus v2, while your chassis (P38471-B21) is for the Gen10 Plus (1st gen). You should use the P02375-B21 rail kit for proper alignment with your chassis. [community thread]

What should I do if the BIOS update on my ProLiant DL20 Gen10 fails?

To resolve a failed BIOS update, try downloading the firmware directly from the manufacturer's website and use the iLO web interface for the update. Alternatively, consider using the latest Service Pack for ProLiant (SPP) for the update process. [community thread]

Why am I getting a 503 Service Unavailable error when trying to access the Redfish API on my UCS C220 M5SX?

The Redfish API is not supported by Cisco UCS Manager (UCSM) and is only available directly through the CIMC of the server. Ensure that you are accessing the Redfish API via the CIMC interface, where it should be enabled by default. [community thread]

Why can't I boot the HUU from a KVM mapped DVD on a UCS C220 M5 server?

If you encounter an incorrect signature message while trying to boot the HUU, ensure that you are using a compatible version of the HUU. Some users have successfully run the HUU with Secure Boot enabled, so consider checking for any firmware updates or using a different version of the HUU. [community thread]

What should I do if I receive an 'Invalid HUU ISO image' error when using the getfw tool on a C220 M4 server?

To resolve this issue, ensure you are using a newer CIMC ISO version when running the getfw tool. Download and extract a compatible ISO, such as 4.1(2k), and then execute the getfw command from the extracted folder, pointing it to the appropriate HUU ISO file. [community thread]

Is Proxmox VE compatible with Cisco UCS C/X Series servers?

Proxmox can be used on Cisco UCS C/X Series servers, but support may be limited. For any issues, it's advisable to verify them on a supported operating system and engage with Cisco TAC for assistance, as they only support configurations listed on the UCS Hardware Compatibility List (HCL). You can also request official support for Proxmox through your sales team. [community thread]

Is the Cisco Integrated Management Controller M4 affected by the known bug?

Yes, all CIMC versions, including the M4, are affected. Since the M4 has reached its end of life, the recommended action is to disable the CIMC web server through SSH commands. [community thread]

What should I do if I encounter a memory error when installing 256GB of RAM in a PowerEdge R540?

Ensure that the DIMMs you are using are compatible with the R540, as some models may not be supported. For optimal performance, populate the memory slots according to the server's guidelines, typically using slots 1, 2, 4, and 5 for four DIMMs per processor. If issues persist, consider testing with different DIMM configurations or consult the server's documentation for further assistance. [community thread]

What should I do if my T430 server's local video output is not working after POST?

First, ensure that the video cable and monitor are properly connected, and try using a different monitor or cable to eliminate hardware issues. If possible, access the iDRAC to check if local video output is enabled in the BIOS settings, or reset the BIOS by removing the CMOS battery for a few minutes. If these steps do not resolve the issue, inspect the motherboard for any visible damage or consider testing with a different operating system. [community thread]

How can I activate a second processor on my PowerEdge R750xs?

To enable a second CPU on the PowerEdge R750xs, ensure you have all necessary components, including a compatible heatsink. It is recommended to consult with sales for a complete kit that includes all required parts. [community thread]

How can I identify the NICs on my R750 server?

To determine the NICs, access the iDRAC GUI and check the network cards section for their MAC addresses, then match them with your list. Additionally, refer to the server's manual, which provides a layout of the NICs and their corresponding slots. [community thread]

How can I enable NVME SSD functionality in the front bays of my R740XD server?

To enable NVME SSD functionality in your R740XD, you will need to check the current configuration and identify the necessary parts, particularly the backplane. Refer to the server's documentation for specific part numbers and compatibility details. [community thread]

Why are my drives not appearing in the configuration menu on my Dell T350 server?

The issue may stem from the supplied cable, which only supports four drives. To utilize all eight drive bays, consider using a separate controller, such as the PERC H355, along with the appropriate cable. [community thread]

What GPUs can I install in an R740 without increasing fan speed?

To avoid increased fan speeds, only use GPUs listed on Dell's certified GPU list for the R740, as any not on this list are generally treated as third-party cards. For detailed compatibility, refer to the PowerEdge Server GPU Matrix. [community thread]

Why is the iDRAC not displaying new firmware updates for my server?

Ensure that the iDRAC is connected to the internet and can access the Dell downloads site. Clear your browser cache or try using a different browser to check for updates. Additionally, verify if the firmware is already up to date by checking the System Event Log for any related errors. [community thread]

Why does the iDrac diagnostic package freeze during storage initialization on an R760 server?

This issue may be resolved by updating the diagnostic software from version 4303A09 to 4303A15. Ensure that all components are properly connected and functioning before running the diagnostics again. [community thread]

What are the common failure rates associated with the R760 server hardware options?

Dell does not provide specific mean time between failure (MTBF) data for the R760 servers due to numerous variables affecting reliability. However, enterprise SSDs generally have a higher MTBF rating compared to traditional hard drives. For optimal support, maintaining an active service contract is recommended. [community thread]

What should I do if my PowerEdge R760's 100G cable is not functioning?

If your 100G cable is faulty, consider obtaining a replacement. You can find parts and upgrades through the official Dell website or contact their support for assistance. [community thread]

How can I identify a faulty DIMM slot on my PowerEdge R6515 server experiencing memory errors?

To pinpoint the problematic DIMM slot, consider disabling the EDAC driver to allow the server's lifecycle controller to log the error more effectively. You can blacklist the EDAC modules by editing the '/etc/modprobe.d/blacklist.conf' file and adding the relevant modules, then reboot the server and run hardware diagnostics. [community thread]

What can I do if my refurbished server is experiencing slow performance after installing 2025 Datacenter?

To address performance issues, ensure that your server's BIOS, iDRAC, CPLD, PERC controller, and drives are all updated to the latest versions, as the recent OS release may require these updates for optimal performance. Additionally, consult the OS vendor's guidelines for setup best practices. [community thread]

What should I do if my Dell R740 server experiences CPU lockups?

To address CPU lockups, consider updating the BIOS, iDRAC, and CPLD firmware. Additionally, check for any warnings in the system event logs and ensure that the operating system is not running on a problematic storage card. Enabling processor x2APIC support may also be beneficial. [community thread]

Why is my R440 server showing an unsupported processor error after upgrading to a Xeon Gold 6242?

If your R440 server displays an unsupported processor error, ensure that you have the correct system board version, as the Xeon Gold 6242 requires system board 4JN2K for proper functionality. Additionally, verify that your power supply meets the necessary specifications, such as having a minimum of 550W. [community thread]

Is the inno3d GeForce RTX 3060 compatible with the Dell EMC R740 server?

The inno3d GeForce RTX 3060 is not officially supported on the Dell EMC R740, as it belongs to the consumer category and has not been tested for enterprise use. The R740 is compatible with specific Nvidia enterprise GPUs such as the A2, A10, A16, A30, A40, A100, and A800. For successful GPU installation, ensure that the appropriate GPU enablement kit and cooling solutions are in place. [community thread]

Can I expand the storage array on a Dell PowerEdge T440 with existing RAID configuration?

To determine if you can extend the current array, check the RAID controller model and its support for Online Capacity Expansion (OCE). Refer to the user guide for your specific RAID controller to find detailed instructions. [community thread]

How do I ensure power redundancy on my Dell PowerEdge T440 server?

To maintain power redundancy on your Dell PowerEdge T440, verify that both power supply units (PSUs) are functioning correctly and are updated to the latest firmware. Enabling the Hot Spare feature allows one PSU to act as a backup, but it may lead to increased load on the active PSU, which could cause issues during power outages. [community thread]

What do I need to install two GPUs in a PowerEdge R940XA server?

To install two GPUs in a PowerEdge R940XA server, you will require 16x risers and the appropriate power cables. There is no specific GPU Enablement Kit available for this server. [community thread]

How can I retrieve the MAC address for Dell R760 and R750 servers when encountering a platform support error?

To obtain the MAC address, you can use the RACADM command 'racadm getniccfg' or the IPMI tool with the command 'ipmitool lan print'. Both methods should provide the necessary information. [community thread]

What could be causing my R740xd 24NVMe server to fail to boot after installing NVMe components?

The issue may stem from missing or incorrect cables required for the NVMe configuration. Ensure that you have the correct riser cards and all necessary power cables as outlined in the installation guide, and consider consulting with a sales engineer for confirmation on the required components. [community thread]

Why are my hard drives not recognized when installing ESXi on a Dell PowerEdge T150 with RAID 1 configured?

Ensure that your RAID 1 array is properly initialized in the RAID controller's BIOS, as incorrect settings can lead to drives not being detected during installation. It's also important to keep your server's firmware and RAID controller drivers updated, and consider using Dell's customized ESXi images that include necessary drivers. Additionally, verify your BIOS settings and try switching between AHCI and RAID modes if issues persist. [community thread]

What should I do if my Dell PowerEdge R750xs servers lose display and input connections after installing Ubuntu Server?

Check the version of Ubuntu you are using and review the OS logs for any issues. Additionally, verify the BIOS and iDRAC firmware versions, as well as the compatibility of your installed hardware components. [community thread]

Can I upgrade my DELL T360 server to support more than 4 drives?

Yes, the DELL T360 can be upgraded to support additional drives using a BOSS kit. You can find the necessary parts, such as the BOSS Enablement Kit and the required fan, through Dell's sales or spare parts teams. [community thread]

What is the product number for the Dell TPM 2.0 module compatible with the Poweredge T430?

The Poweredge T430 does support a TPM module, and the correct part number for the TPM 2.0 is K98XH. It is important to note that any installation or removal of the TPM should only be conducted by certified technicians, as it is bound to the motherboard. [community thread]

Why is my R740 not recognizing the Intel 82599ES Dual SFP NIC?

The Intel 82599ES NIC is not compatible with the R740 server. Supported Intel NICs for this model include the i350, X520, X710, and E810. If you need to use a compatible NIC, consider one of these options. [community thread]

Why am I receiving an error message when trying to enable a TPM 1.2 module on my T140 server?

The error may occur because the TPM module is cryptographically bound to a specific system board, preventing it from being used on another server. If the module is refurbished or not compatible, it could lead to activation failures. It is advisable to use a module that is confirmed to be compatible with your server model. [community thread]

Can I use different riser configurations for a Dell R740xd to connect a GPU and NVMe drives?

It is recommended to use riser cards as specified in the official configurations, as untested combinations may not be supported. Custom configurations like combining Riser 1A and 2C are not guaranteed to work, and additional components such as cables may be necessary for full functionality. [community thread]

Why does my Dell PowerEdge R450 server shut down every week without any logs?

Check the iDRAC's Lifecycle logs for any indications of issues. Additionally, consider whether there are power fluctuations in your environment, as these can cause unexpected shutdowns. [community thread]

Why does the firmware update for the 14G Expander Backplane on the PE R540 fail with error SUP0517?

The error may occur due to the use of a non-Dell HBA card, which can prevent the backplane from being updated automatically. To resolve this, consider using the Dell Server Update Utility to perform the firmware update. [community thread]

Why is the NVIDIA GPU Tesla T4 not showing in the BIOS of my Dell R640 server after deploying EKS Anywhere?

The issue may stem from compatibility, as EKS Anywhere is primarily certified for use with specific Dell products like VxRail and PowerStore. Verify that the Tesla T4 GPU is a genuine Dell part and check the part number for compatibility. [community thread]

Why is my PowerEdge T150 not booting with memory installed in the A2 slot?

It appears that the A2 slot may be malfunctioning, as it does not detect memory when tested. Consider cleaning the slot for any corrosion and ensure that your server's BIOS and firmware are updated. Additionally, testing with different memory configurations and clearing the NVRAM may help resolve the issue. [community thread]

What does it mean if the PowerEdge R440 motherboard LEDs DS1 and DS7 are blinking and the server won't boot?

The blinking LEDs indicate a potential configuration issue with the processor or memory. Ensure that the memory is installed correctly according to the guidelines and that the primary CPU is properly seated and compatible. If the problem continues after verifying these components, consider testing with a different motherboard. [community thread]

What should I do if my refurbished Dell PowerEdge R6525 is experiencing random reboots?

To troubleshoot random reboots, check for any error messages around the time of the reboots and ensure that all firmware and software are updated. Run diagnostics using Dell SupportAssist, reseat hardware components like memory and CPUs, and monitor temperatures to prevent overheating. Additionally, verify the power supply and consider testing with a different one if issues persist. [community thread]

Does the Poweredge T440 have a UEFI BIOS option labeled 'ROM' in its settings?

The Poweredge T440 features UEFI booting capabilities, but there is no specific 'ROM' option available in the settings. For booting from NVMe drives, a BOSS controller is required. [community thread]

What does slot 40 refer to in an R640 server and how can I resolve related errors?

Slot 40 in an R640 server typically indicates a specific component location on the motherboard. If you encounter errors related to this slot, it's advisable to analyze the server logs for further insights and contact local support for assistance in diagnosing the issue. [community thread]

Is Samsung server memory and Seagate Ironwolf Pro hard drives compatible with the Dell PowerEdge R250?

The Samsung server memory and Seagate Ironwolf Pro hard drives are not certified or tested by Dell for compatibility with the PowerEdge R250. Therefore, their performance cannot be guaranteed unless confirmed by a user who has tested them. [community thread]

Why won't my R730 server boot from the PCIe storage with M.2 SSDs?

The R730 server does not support booting from PCIe M.2 SSDs due to firmware limitations, as this capability is only available in 14th generation servers. Additionally, the Dell UEFI does not have NVMe support, which may prevent the server from recognizing the bootable drives on the PCIe card. [community thread]

Why won't my Dell Poweredge T430 server power on after upgrading to dual hot-plug power supplies?

Ensure that the control panel cable is properly connected to the system board. If the issue persists, try disconnecting the control panel cable, holding the rear iButton for 15 seconds, and then reconnecting everything to see if it powers on. [community thread]

What do the motherboard LED codes indicate for a PowerEdge R640 that won't start?

If the PowerEdge R640 fails to power on and the iDRAC does not initialize, the LED patterns can help diagnose the issue. A flea power drain and clearing the NVRAM may resolve the problem; if not, test with only the minimum components required for POST to identify any faulty parts. [community thread]

What are the requirements for upgrading the CPU in a Dell R640 server?

Upgrading to a Xeon Silver 4210 in a Dell R640 does not require a different system board, but it is important to ensure that the system board firmware, including iDRAC and BIOS, is up to date. Additionally, due to regional differences in part numbers, it's advisable to consult with sales for specific upgrade guidance and quotes. [community thread]

What does an amber flashing light on the PowerEdge T140 motherboard indicate?

An amber flashing light on the motherboard may signal a hardware issue. It is advisable to utilize diagnostic tools to identify the specific problem. [community thread]

Is it normal for the NVIDIA Tesla M60 GPU in a Dell R730 server to consume only 190W during benchmarking?

A power consumption of 190W for the M60 GPU is lower than its maximum TDP of 250W, which may indicate a limitation in software, hardware configuration, or system settings. To investigate, ensure that the latest NVIDIA drivers are installed, check BIOS settings for proper GPU configuration, and consider testing with different benchmarking tools to assess the GPU's performance. [community thread]

Is the TPM Module 8T8C5 compatible with the T430 server?

Yes, the TPM Module 8T8C5 is compatible with the T430 server. If you encounter issues like 'Unsupported TPM Hardware' in the BIOS, ensure that the module is properly installed and that your system firmware is up to date. [community thread]

What should I do if the watchdog timer resets my server?

This issue typically indicates that the server's watchdog timer has timed out or failed to reset properly, often due to the server being unresponsive. To address this, check the hardware logs for any related errors, and ensure that the BIOS, iDRAC, and PERC controller are updated to the latest versions. [community thread]

What does the PCIe error referencing 'Bus 0 Device 1 Function 0' indicate and how can I resolve it?

This error typically points to an issue with the CPU. Consider testing with a different CPU in a minimal configuration or replacing the motherboard if the problem persists. [community thread]

What should I do if my PowerEdge R730 shows no video signal and I can't access iDRAC?

To troubleshoot the video issue, try using a standard VGA monitor instead of an HDMI adapter, as the latter may not be supported. Additionally, simplify the server's configuration by removing all non-essential components and booting with just the system board, one power supply, one CPU, and one memory module. For iDRAC access, you can reset it to factory settings using the command 'racadm racreset cfg -rc'. [community thread]

Why does the NVIDIA Bluefield-2 firmware keep appearing for my R650 or R750 server when it is not installed?

This issue may be due to a misconfiguration in the firmware catalog, causing the incorrect firmware to be suggested for your system. The Systems Management team is aware of the problem and is working on a resolution, which may be included in a future firmware release. [community thread]

Can I upgrade the memory in my PowerEdge T440 without adding another CPU?

Yes, you can increase the memory in your PowerEdge T440 by adding more DIMMs to the existing slots. However, be aware that adding more DIMMs may lead to a performance decrease since it will utilize a second memory channel, which could impact performance depending on your server's workload. [community thread]

How can I connect NVME drives to a PERC controller for RAID configuration on an R760 server?

To connect NVME drives to the PERC controller on an R760 server, you need to change the configuration to allow for NVME drives to be recognized by the controller. This typically involves adjusting the server's settings to enable the appropriate slots for NVME, ensuring they can be included in a RAID setup. [community thread]

What is the correct firmware update sequence for a refurbished R730 server?

To update the firmware on an R730 server, first ensure that the iDRAC is updated to the latest version before proceeding with the BIOS update. It is advisable to update firmware incrementally, following the release dates, and to verify the integrity of the downloaded files by checking their checksums. [community thread]

Why do the fans on my DL380 Gen10 run at full speed for a few seconds daily?

It is normal for server fans to operate at maximum speed during certain conditions, such as system checks or workload spikes. To investigate, check the iLO system information for temperature and performance metrics, ensure there are no airflow obstructions, and confirm that all firmware is up to date. If the issue persists without any logged errors, it may be a routine operational characteristic. [community thread]

What should I do if my HP ProLiant ML110 Gen11 is stuck at 'starting required devices please wait'?

This issue often indicates a problem with firmware or hardware during the POST process. To resolve it, power down the server completely, disconnect the power cord, and hold the power button for 20-30 seconds. Then, boot with only essential components, disable TPM/Secure Boot if possible, and ensure the firmware is up to date. If the problem persists, it may be necessary to check the memory, reseat components, or consult support for potential hardware faults. [community thread]

What should I do if my DL385 Gen10 Plus server displays a thermal fault error?

If your server shows a thermal fault error, it may be related to the LOM card or the front power module. Consider checking the LOM interface for overheating issues and consult with support for potential replacements of the power module. [community thread]

What should I do if my DL360 Gen10 does not recognize installed Persistent Memory?

Ensure that your BIOS is updated to the latest version. If the System Programmable Logic Device revision is below the required level, contact HPE support to obtain the necessary CPLD update. [community thread]

What type of connectors are used on the DL385 Gen11 mainboard for storage drives?

The DL385 Gen11 features SFF-TA-1016 connectors for the SAS onboard connections and SFF-8654 for the disk box. For NVMe storage, the connector is labeled as 'Wondermiddel SIG,' which may require further research to identify. [community thread]

Why is my ProLiant DL20 Gen11 server making a lot of noise?

A noisy server may indicate that the fan is operating at a higher speed than necessary, which can be due to firmware settings or sensor issues. Check the fan control settings in BIOS and iLO to ensure they are set to 'Automatic' or 'Standard', and verify that your firmware versions are up to date. Additionally, inspect the Integrated Management Log for any errors and ensure proper airflow and environmental conditions. [community thread]

Can I set up hardware RAID with NVMe drives on an HP DL380 Gen10 server?

The HP DL380 Gen10 server primarily supports software RAID for NVMe drives, as their architecture is not compatible with hardware RAID configurations. For hardware RAID, ensure that storage devices are directly connected to a compatible storage controller, and refer to the server's QuickSpecs for a list of supported RAID controllers. [community thread]

What is the maximum number of drive cages and cables needed for a DL380 Gen10 with an MR416i controller for hardware RAID of NVMe drives?

The HPE ProLiant DL300 Gen10 Plus 2U 8SFF x4 Tri-Mode 24G U.3 BC Front Drive Cage Kit supports a combination of SAS, SATA, and NVMe drives, allowing for a maximum of 16 drives when using two cages. For connecting the controller to the cages, the HPE DL38X Gen10 Plus 8NVMe CPU1/2 Cable Kit is recommended, while the HPE DL300 G10+ 2U x1/x2 Tri-Mode Cable Kit is not compatible. [community thread]

What GPU can I use for deep learning in a DL380 Gen10 server?

The DL380 Gen10 supports specific GPUs listed in the QuickSpecs, such as the NVIDIA A40 and A30. While some users may attempt to use models like the RTX 3090, compatibility and performance are not guaranteed. It's advisable to stick with tested options for optimal functionality. [community thread]

Does the Bezel Lock Kit come with a key?

Yes, the Bezel Lock Kit for the HPE ProLiant ML110 Gen11 includes a key for the front door/bezel lock feature. [community thread]

Why is my NVMe SSD showing a 'Failed' status in the Integrated Management Log on my DL380 Gen11 server?

The issue may arise from using non-HPE branded NVMe drives, which might not be fully supported by the server's BIOS or RAID controllers. Additionally, ensure that the drive cage and fan kit are compatible with the number of drives installed, as specified in the quickspecs. [community thread]

Can I expand a RAID10 array on a DL360 G10 without losing data?

Yes, you can increase the size of the RAID10 array by removing the hot spare and adding a new drive. It is advisable to perform these changes offline to minimize risks, and a full data backup is recommended before proceeding. [community thread]

How can I successfully update Intelligent Provisioning on a DL360 Gen10 server?

To update Intelligent Provisioning on a DL360 Gen10, ensure your firmware stack is current, particularly iLO version 3.17 or later. If you encounter errors, try re-downloading the recovery ISO, fully power cycling the server, and using intermediate versions like 3.86 or 3.89 before attempting the update to 3.92. [community thread]

How do I connect a single SATA drive to a DL385 Gen11 server?

To connect a SATA drive, use the 1A connector on the motherboard, as it is linked to the primary SATA controller. Note that the server's backplane may not support SATA drives, so you might need a different backplane if it only accommodates SAS drives. [community thread]

Why is my HPE DL380 Gen10 server not booting after installing new RAM modules?

The issue may stem from a speed mismatch, as the Intel Xeon Gold 5115 processor only supports a maximum DIMM speed of 2400 MT/s, while the installed RAM operates at 2933 MT/s. Additionally, ensure that the RAM modules are compatible with the installed processors, as mixing different types of DIMMs is not supported. For optimal performance, use DIMMs that match the processor's specifications. [community thread]

Why is my ProLiant DL380 Gen10 server running its fans at high speeds despite low load and normal temperatures?

High fan speeds can occur due to various reasons, including firmware issues. It's advisable to check for any necessary firmware updates, particularly for the Innovation Engine, and consult the support documentation for troubleshooting steps. [community thread]

What is the model of the MR controller for the DL380 Gen10 Plus and what are the cable part numbers?

To identify the MR controller model and obtain the cable part numbers, refer to the 10th section of the provided support link, which contains the necessary details. [community thread]

Can the HPE DL360 Gen10 be upgraded to support U2 NVMe drives?

To enable U2 NVMe support on the HPE DL360 Gen10, you will need to replace the existing P408i-a controller with the MR416i-a controller. The current backplane can remain in place. [community thread]

Why is the fan speed control on the DL20 Gen10 problematic?

The DL20 Gen10 features small fans that tend to operate at higher speeds, resulting in increased noise levels. For quieter operation, consider using a larger server model, such as a 2U or 3U server, which can significantly reduce noise in sensitive environments. [community thread]

Why can't I use an FQDN for the syslog entry after updating to iLO firmware version 1.69 on my DL360 Gen11 server?

After the update to iLO firmware version 1.69, the requirement changed to using an IP address for remote syslog destinations. To restore the ability to use an FQDN, it is recommended to update to iLO firmware version 1.70, which has resolved this issue. [community thread]

Is the Nvidia L40 GPU compatible with the DL380 Gen10 server?

To determine compatibility, refer to the official list of supported GPUs for the DL380 Gen10, which can be found on the HPE support website. [community thread]

How do I set up PCIe bifurcation on HPE DL360/DL380 Gen10 servers?

To configure PCIe bifurcation, ensure your PCIe card supports it and adjust the BIOS settings accordingly. Navigate to System Configuration > RBSU > PCIe Device Configuration > Advanced PCIe Configuration, and select the appropriate bifurcation option for your slot. Additionally, disable Intel VMD Support under Service Options for optimal performance. [community thread]

What can I do to reduce excessive fan noise on my HP Proliant DL380 Gen 10 Plus?

To address loud fan noise, first ensure that all components are properly seated and that any empty slots have appropriate blanks installed. If the issue persists, try removing any non-essential components to see if that affects fan operation. [community thread]

What power cable is needed for an NVIDIA RTX A4000 GPU in a Proliant DL360 Gen10 server?

The NVIDIA RTX A4000 requires a 6-pin power connector, while the DL360 Gen10 server uses an 8-pin mini connector. If using a DL360 Gen10 Plus, the compatible cable is the HPE ProLiant DL36X Gen10 Plus CPU1 A4000 GPU Cable Kit (P50031-B21). For the DL360 Gen10, the GPU is not supported. [community thread]

What NVMe riser or adapter can I use for a DL360 Gen10 server to install an M.2 boot drive?

For the DL360 Gen10, consider the HPE DL360 Gen10 x16/x16 SATA M.2 2280 Riser Kit, part number 867978-B21, which can be installed in the primary riser without occupying a PCIe slot. If the primary riser is already in use, you may need to explore options for an adapter that fits the available PCIe slots, keeping in mind that an 8x slot may limit performance compared to a 16x solution. [community thread]

Why is my DL385 Gen11 server with AMD 9174F making loud fan noises?

Check the 'Fan and thermal issues' section in the Troubleshooting Guide for HPE ProLiant Gen11 servers for potential solutions. If the cooling settings are set to 'Optimal Cooling,' consider that fan noise may increase significantly when fan speeds exceed 35%. [community thread]

Can I use an MR416i-p x16 Lanes 4GB from a ML350 Gen10 Plus in a ML350 Gen11?

The MR416i-p x16 Lanes 4GB from the ML350 Gen10 Plus is not compatible with the ML350 Gen11. It is recommended to use the MR416i-p Gen11 model for the ML350 Gen11 to ensure proper functionality. [community thread]

What components are necessary to install an Nvidia Quadro RTX 6000 in an HPE Proliant DL380 Gen10 server?

To install the Nvidia Quadro RTX 6000, you will need the HPE DL38X Gen10 8x 6-pin Cable Kit, High Performance Heat Sink Kit, and High Performance Temperature Fan Kit. Additionally, ensure that a GPU riser card or cage is already installed, as it may be required for proper installation. You can verify the complete list of necessary components through HPE's support documentation. [community thread]

Why won't my Nvidia Quadro RTX 6000 work with my DL380 Gen10 server?

Ensure that you are using the correct power cable, as the GPU requires an 8-pin to 6-pin Y-cable instead of an 8-pin to 8-pin. Additionally, verify that the graphics card is securely seated in the riser and check the Integrated Management Log for any error messages. Confirm that your server meets all specifications for the GPU model. [community thread]

How can I convert my RAID 1 setup to RAID 10 on an HPE DL360 Gen10 server without losing data?

To change your RAID 1 configuration to RAID 10, first ensure that all four drives are identical and properly recognized by the server. Use the HPE Smart Storage Administrator (SSA) or a similar tool to access the RAID controller during startup, and select the option to convert the existing RAID 1 array to RAID 10, ensuring that the process is set to non-destructive to retain your data. [community thread]

Why does my USB boot show an error saying 'You need to install the kernel first' while the same ISO works from a virtual CD?

This issue may arise from a corrupted SPP file on the USB drive. Consider re-downloading the SPP and trying again, or use the automatic update option to see if that resolves the problem. [community thread]

What should I do if my ML110 Gen11 server is stuck in a boot loop while updating iLO firmware?

If your server is continuously rebooting during the iLO firmware update, try powering it off completely, disconnecting it from the power source, and then draining any residual power by pressing the power button. After reconnecting the power, attempt to access the iLO web interface to check the firmware status or perform further updates. [community thread]

Why is my Siemens CP1623 card not being detected in my HPE Proliant DL380 Gen11 server?

The Siemens CP1623 card is not officially supported by HPE, which may lead to detection issues. However, users have reported success by adjusting the PCIe settings in the BIOS to set the Maximum PCI Express Speed to PCIe generation 1.0. [community thread]

Why is my HPE DL380 Gen10 server's fan running loudly after a firmware update?

Increased fan speeds can occur after firmware updates, especially if non-HPE drives are installed. To troubleshoot, try replacing third-party drives with HPE-certified drives and monitor the fan behavior. [community thread]

What GPU is recommended for use with the ProLiant DL380 Gen10 Plus for OBS?

The NVIDIA H100 NVL 94GB PCIe Accelerator is suggested for the HPE ProLiant DL380 Gen10 Plus. For further details and additional GPU options, consult the QuickSpecs. [community thread]

What should I do if my HP Proliant ML350 Gen10 is shutting down due to overheating warnings despite normal temperature readings?

First, ensure that the iLO and BIOS are updated to the latest versions. If the issue persists, check the firmware of all installed drives, as faulty or outdated firmware can cause incorrect temperature readings. Additionally, consider monitoring the temperature sensors for any anomalies that may indicate a hardware issue. [community thread]

Can I add a GPU to an HPE ProLiant DL20 Gen10 server?

The HPE ProLiant DL20 Gen10 does not support internal GPUs, and while there may be external GPU options, they are not specified in the QuickSpecs. For further assistance, it is advisable to consult HPE Sales or a reseller regarding compatible setups. [community thread]

Why is my ML110 Gen10 server's fan running at a higher speed after a firmware upgrade and NIC installation?

The increased fan speed may be due to the installation of an incompatible network card, which can affect system cooling. Ensure that the correct AMS version is installed and verify that all components are properly seated and compatible with the server. [community thread]

Why can't I attach an NFS ISO after upgrading my iDRAC firmware?

If you're experiencing issues attaching an NFS ISO after an iDRAC firmware upgrade, consider reverting to the previous firmware version to see if that resolves the problem. Alternatively, updating to the latest BIOS and iDRAC firmware may fix the issue, as recent updates have addressed connectivity problems with NFS shares. [community thread]

Why does my PowerEdge R650 server have a gray iDRAC interface instead of the usual blue one?

The gray iDRAC interface is typically a cosmetic difference and does not indicate any issues with the server's health. It is advisable to ensure that all system firmware is current for optimal performance. [community thread]

How can I check if the firmware on my PowerEdge R750 server is current?

You can verify the firmware status by accessing the iDRAC WebGUI and using the Maintenance option to initiate a firmware upgrade via HTTPS. Alternatively, for managing multiple servers, consider using Dell OpenManage Essentials (OME) for a comprehensive overview of firmware updates. [community thread]

What should I do if my Dell R760 shows a temperature sensor warning in iDRAC 9?

Access the iDRAC 9 Web GUI and check the actual temperature under Maintenance > System Health > Temperatures. Compare this reading with your set warning thresholds using the Dell SNMP Reference Guide. If the iDRAC shows normal temperatures but you receive alerts via SNMP, consider adjusting your monitoring tool's configuration. [community thread]

Why is the serial console on my Dell R440 server not functioning?

The issue is likely linked to the expired iDRAC 8 Enterprise License. You can obtain a trial license from Dell or refer to their documentation on acquiring licenses from the Dell Digital Locker. [community thread]

How do I install Optane Memory in a DL380 Gen10 server?

To successfully install Optane Memory in a DL380 Gen10 server, ensure that you populate either 4, 6, or 8 DIMMs per CPU. Only Optane 100 series, referred to as HPE Persistent Memory, is compatible, and you must fill the slots according to the server's memory population guidelines. [community thread]

What can I do if the front fans on my ML350 Gen10 are running at high speeds?

To troubleshoot high fan speeds, first remove any third-party devices to see if that resolves the issue. If the problem persists, consider adjusting the cooling settings or checking for any firmware updates that may address fan control. [community thread]

Why is my HP ProLiant DL385 Gen10 running memory at a lower frequency than expected?

If your server's memory is operating at a lower frequency, it may be due to the presence of memory modules with different specifications. Ensure that all installed memory modules are of the same speed; if any module has a lower frequency, it will cause the entire system to operate at that lower speed. [community thread]

How can I resolve the 'Not Authenticated' status for an HDD in a DL360 Gen10 server?

Try re-seating the HDD in the affected bay to see if that resolves the issue. If the problem continues, test the bay with a different, known good drive to determine if the issue is with the bay itself. [community thread]

Is there a tool available for the ThinkSystem SR630 V2 to simplify driver updates?

Yes, the Lenovo XClarity Essentials UpdateXpress (UXSP) tool allows for easy updates of drivers and firmware on the ThinkSystem SR630 V2. You can download it from the Lenovo Support website by searching for your specific server model and accessing the 'Drivers & Software' section. [community thread]

What should I do if my Dell PowerEdge R430 shows a persistent BAT0017 error despite replacing the CMOS battery?

First, perform a full power drain by disconnecting all power cables, holding the power button for 30 seconds, and leaving the server unpowered for 15-20 minutes with the battery removed. Additionally, check the tension of the battery holder to ensure a secure connection, and verify if the error might be related to a failing PERC RAID controller battery instead of the CMOS battery. [community thread]

What should I do if I encounter an 'Error: No such device embedded 310' message while using Intelligent Provisioning on a DL380 Gen10 server?

This error may indicate an issue with the server's configuration or hardware. Ensure that all components, including the SFP cards, are properly installed and compatible with the server. If the problem persists, consider gathering detailed logs and contacting technical support for further assistance. [community thread]

Why is my ProLiant DL20 Gen10 server making excessive noise?

If your ProLiant DL20 Gen10 server is excessively loud, check the fan settings in the RBSU. Adjusting the cooling mode to 'Increased Cooling Mode' may help, but if it worsens the situation, consider reverting to the default settings or consulting the manufacturer's support documentation for further guidance. [community thread]

What should I do if my server shows a 3019 error indicating the Server Platform Services firmware is in recovery mode?

This error typically occurs due to a corrupted SPS firmware image. To resolve the issue, you should update the Server Platform Services firmware. [community thread]

Why am I receiving temperature alerts when connecting a Promise storage enclosure to my Proliant DL380 Gen10?

The temperature warnings are likely due to a mismatch in how the iLO 5 interprets sensor data from the Promise enclosure, which it does not fully support. To resolve this, update the firmware for the iLO, server BIOS, P408e-p controller, and the Promise enclosure. Alternatively, replacing the P408e-p with a Broadcom controller may eliminate the false alerts. [community thread]

Can I use an E208i-A SR controller with an 878783-B21 M.2 SATA kit for booting VMware on a DL380 Gen10 server?

The E208i-A SR controller may not support M.2 SATA drives for RAID configurations, as these drives are typically managed by software RAID controllers like the S100i. While it might allow OS installation in HBA mode without RAID, there is no documentation confirming its compatibility for creating RAID 1 with M.2 SATA drives. [community thread]

What should I do if my HP Proliant ML350 Gen10's temperature sensor is showing unusually high readings and causing the fans to run at maximum speed?

First, ensure that all installed SATA drives are HPE-certified, as third-party drives may lead to incorrect temperature readings. If the issue persists, perform a power drain, update the iLO and BIOS to the latest versions, and monitor fan behavior during POST and OS boot to identify when the issue occurs. If necessary, consider replacing the array controller. [community thread]

Why are the fans on my DL380 Gen10 running at high speed continuously?

To address the issue of fans running at high speed, first check the fan and thermal settings in the BIOS and set it to 'Optimal Cooling' or 'Increased Cooling.' If the problem persists, try disconnecting all power and external cables, then hold the power button for 10 seconds to drain residual power. After reconnecting, check the fan operation again. [community thread]

What should I do if my server's iLO shows a degraded health and storage status without any visible errors?

To address the degraded health and storage warning, first review the Integrated Management Log (IML) for any component warnings. Next, inspect the DIMMs and drives for potential issues, and check each component individually in iLO for alerts. [community thread]

How can I successfully update the system ROM on a DL360 Gen10 server?

To update the system ROM, check the iLO Overview page for current and redundant ROM information. If the update fails, try resetting iLO from the Diagnostics page and reattempt the firmware update. Additionally, consider flashing the BIOS directly from the operating system using the appropriate command syntax. [community thread]

Why are the fans on my HPE DL20 Gen10 running at 43% continuously?

This issue may be related to the server's hardware configuration or firmware settings. It is advisable to check if the server is equipped with HDDs or SSDs, and consult the relevant customer advisory from HPE for further guidance. [community thread]

Why is the 'Secure with SSL/TLS' option grayed out in MR Storage Administrator?

The 'Secure with SSL/TLS' option may be disabled if the 'Legacy' checkbox is selected in the settings. For detailed instructions, refer to page 57 of the user guide available at the provided link. [community thread]

Can I set up a JBOD configuration on an R640 without an internal RAID controller?

To implement a JBOD setup on the R640, you will need an external SAS 12Gbps Host Bus Adapter. The H840 controller does not support JBOD or HBA mode, so consider using the MD1400 with the appropriate adapter for your configuration. [community thread]

How can I connect two Nvidia A16 GPUs to a PowerEdge R740xd and ensure both are recognized?

To connect two Nvidia A16 GPUs, you may need a power extension card to properly distribute power between the GPUs in risers 1 and 2. Additionally, verify the power requirements; using two 750W PSUs may not be sufficient, and upgrading to two 1100W PSUs could be necessary. [community thread]

How can I reset the BIOS settings to default for a server after changing processors?

To restore the BIOS to its default settings, press <F2> during boot, navigate to <System BIOS>, and select the Defaults option. Additionally, you can clear the NVRAM by locating the NVRAM_CLR jumper, setting it to the Clear position, powering on the server until you see a jumper error, then shutting down and returning the jumper to its original position. [community thread]

What are the RAM and PCI-E configuration options for the Dell PowerEdge R440 when using a single CPU?

When operating with only CPU 1, the maximum supported RAM capacity is limited, and compatibility with 64GB DDR4 modules may vary. However, the X520-DA2 network card requires both CPUs for full functionality, so it cannot be maintained with a single CPU configuration. [community thread]

What should I do if I encounter an unknown error while installing Rocky Linux on a T430 server?

To resolve the installation issue, ensure that the logical drive on the RAID controller is fully initialized and that the appropriate RAID controller driver is loaded. Additionally, consider disabling FIPS if it is enabled, as this may interfere with the installation process. [community thread]

Does the Dell PowerEdge R660 support legacy operating system installations with the latest BIOS version?

The Dell PowerEdge R660 primarily supports UEFI mode for installations. If you are attempting to install a legacy OS, ensure that your hardware configuration allows for legacy boot options, as this may affect your ability to install in that mode. [community thread]

Can the PowerEdge R740 support the unofficial installation of a Dell nVidia Quadro A4000 GPU?

While the PowerEdge R740 may be able to accommodate the Quadro A4000 GPU, it is not officially supported by Dell. For optimal performance and compatibility, consider using GPUs that are officially validated for this server model. [community thread]

What should I do if the firmware upgrade on my R650 times out during the process?

Try running the firmware update again. If the timeout issue persists, consider contacting official support to gather logs for further analysis. [community thread]

What should I do if my R740xd servers are reporting multiple memory errors?

If your R740xd servers are frequently indicating memory errors, consider checking for thermal paste residue on the CPU socket pins and contact pads, as this can cause similar issues. Cleaning these areas may resolve the problem. If the issue persists, it might be necessary to consult with technical support for further diagnosis. [community thread]

Can I disable the Matrox GPU on the HPE DL20 Gen10 and use the Intel UHD Graphics P630 instead?

The Matrox G200 is the primary integrated graphics for the DL20 Gen10 and cannot be disabled. The Intel UHD Graphics P630 can only be utilized if an additional graphics card is installed. [community thread]

What can I do if my HPE Proliant ML350 Gen10 is experiencing slow performance?

If your server is showing significantly reduced write speeds, consider checking the configuration of your RAID setup and ensuring that all firmware and drivers are up to date. Additionally, investigate the possibility of enabling SmartCache if your controller supports it, as this may improve performance. If issues persist after these steps, further diagnostics may be necessary to identify underlying hardware problems. [community thread]

How can I get my NVME disks recognized on an HP DL380 Gen10 server running Ubuntu 20.04?

To ensure your NVME disks are detected, check if the necessary drivers are installed and confirm that the BIOS settings are configured correctly for NVME support. You may refer to online guides for specific instructions on configuring RAID or AHCI settings in the BIOS. [community thread]

How can I resolve the issue of the Smart Array not showing up on my DL360 G10 during boot?

To address the Smart Array issue, press the F10 key during boot to access Intelligent Provisioning. From there, navigate to Smart Storage Administrator, select the available controller, and configure it to create a bootable logical drive. After saving your settings, exit and reboot to attempt booting from the OS media. [community thread]

What is the part number for the 3.5" hard drive caddy for the DL380 Gen10 server?

To find the correct part number for the 3.5" hard drive caddy, check for the spare part number located on the front of the drive where the LEDs are. If you do not have a caddy, you may need to consult the server's documentation or contact support for assistance. [community thread]

Why is my ML350 Gen10 only recognizing half of the installed RAM?

This issue may be due to memory mirroring being enabled, which can limit the usable RAM. Check the memory settings in the BIOS to ensure that memory mirroring is disabled and that the configuration is set to support the full capacity of the installed DIMMs. [community thread]

Why is my HP Proliant DL380 Gen10 showing only 160GB of usable memory after a RAM upgrade?

It seems that one of the memory modules may not be functioning correctly, even though it is recognized by the system. To troubleshoot, access the iLO interface to review the memory details and check the Integrated Management Log (IML) for any related errors. [community thread]

Why is my ML110 Gen10 server with the S100i RAID controller not detecting the drives?

The S100i RAID controller is designed for SATA drives and is incompatible with SAS drives. To use SAS drives, you will need to install a compatible RAID controller, such as the E208i, which supports SAS. [community thread]

Why do the fan speeds differ between Windows Server 2019 and ESXi 7.0 on the DL20 Gen10 server?

Fan speeds can vary based on the operating system's power management settings and hardware configuration. It's recommended to check the drive controller settings, such as whether it's set to AHCI or RAID mode, as this can influence fan behavior. [community thread]

Can I sanitize a drive on an HP ProLiant DL380 Gen10 server using Intelligent Provisioning?

Yes, you can perform a sanitize overwrite using the Intelligent Provisioning's Erase Utility. Access the maintenance options, select Erase Utility, choose the appropriate options for your drives, and confirm the erase process to initiate. [community thread]

What are the requirements for installing an NVMe drive in the HPE DL20 Gen10 server?

To install an NVMe drive, the Dedicated iLO Port/M.2 NVMe SSD/COM Port Upgrade Kit (P06687-B21) is recommended, as it ensures compatibility. The server supports 22110 length NVMe drives, but using third-party NVMe drives may lead to increased fan speeds due to thermal management issues. Additionally, while the server's specifications primarily list a 480GB NVMe option, larger capacities may not be officially supported. [community thread]

Can I use SATA ports 9 and 10 on the HPE Proliant ML110 Gen10 to configure SSDs as a RAID1 array for booting the OS?

Using SATA ports 9 and 10 for SSDs in this configuration is not officially supported. It's recommended to consider alternative solutions, such as the HPE Universal SATA 6G AIC HHHL M.2 SSD Enablement Kit, which requires an available PCIe slot. [community thread]

How can I add more disk space to my HP ProLiant ML350 Gen10 server?

To expand storage on your HP ProLiant ML350 Gen10, check the type of RAID controller installed. If it is a compatible HPE Smart Array with available drive slots, you can add a new drive and perform an online extension to increase the size of an existing logical drive. If there are no free slots, you will need to back up your data and restore it after reconfiguring the drives. [community thread]

Why does my ProLiant DL360 Gen10 show 'cache module status n/a' with SSD drives?

This is typical behavior when HPE SSD Smart Path is activated, as it disables the cache configuration for SSD arrays. If you expected a cache module, verify your order details and compare with other configurations. [community thread]

Why do the fans on my HP DL360 Gen10 server run at full speed after a reboot?

This issue may occur if there is an HBA card installed, which requires a second processor for proper operation. Ensure that you have the latest Service Pack for ProLiant (SPP) applied to address any firmware-related problems. [community thread]

How can I resolve the PCIe bus width issue for my OCP NIC in a DL385 Gen10 Plus server?

To address the PCIe bus width recognition problem, check the server's RBSU settings for options related to I/O Non-posted Prefecting. If the option is not available in your BIOS, it may not be supported for your specific CPU configuration. [community thread]

Why are my Solarflare network adapters not recognized when using HPE STK 11.20 on a DL360 Gen10 server?

The HPE STK 11.20 may not include drivers for your Solarflare network adapters, as it is designed with a limited set of drivers. You can either create a custom kernel that includes the necessary drivers or modify the initrd image to add them. Alternatively, consider using the embedded NIC for initial setup, then disable it and configure your Solarflare cards post-installation. [community thread]

How can I resolve memory configuration errors on an HP Proliant DL360 Gen10 server?

To address memory configuration issues, ensure that all installed DIMMs are compatible with the server and processor. For optimal performance, balance the memory across the channels by using a consistent configuration, such as pairing 32GB and 16GB DIMMs appropriately across both CPUs. [community thread]

Can I upgrade the controller in my DL160 Gen10 server to support both SSD and SAS drives?

Yes, you can replace the S100i controller with the HPE Smart Array E208i-a SR G10 LH Controller and use the appropriate SAS cable kit. This will allow you to configure separate arrays for SSDs and SAS drives. [community thread]

Why are no controllers detected on my HPE DL20 Gen10 server?

Ensure that the SATA controller is configured correctly in the RBSU under Storage Options. The HPE Smart Array S100i SR Gen10 only supports SATA drives, so using SAS drives will result in detection issues. Additionally, a specific driver is required for RAID functionality, which is only available for Windows operating systems. [community thread]

Will a DL360 Gen10 server with a single CPU and a single riser support two dual-port Ethernet cards and one FlexLOM adapter?

The configuration can work, but it's important to verify the bandwidth capabilities of the riser. The HPE Ethernet 10/25Gb 2-port adapters require specific PCI Express slots, and you should consult the riser specifications to ensure it can handle the combined bandwidth of the installed cards. [community thread]

How can I power a 6250 tape drive on an ML350 Gen10 server?

To power the Ultrium 6250 tape drive, refer to the server's QuickSpecs for compatibility and installation requirements. You may need the HPE ML350 Gen10 RDX/LTO Media Drive Support Cable Kit, which includes necessary cables and components for proper installation. [community thread]

How can I reduce the fan speed on a DL20 Gen10 server running in AHCI mode?

To lower the fan speed, install the 'amsd' service, which allows iLO 5 to obtain hard drive temperature readings. After installation, restart the amsd service to see a significant reduction in fan speed. [community thread]

Can I connect a single drive cage to two different RAID controllers in an ML350 Gen10 server?

It is advisable to connect the drive backplane ports to only one RAID controller. To achieve your desired configuration, you will likely need to add a third drive cage for the additional HDD. [community thread]

What should I do if my R730 server shows memory errors after adding a second CPU and RAM?

If you encounter memory reference code errors and incorrect memory recognition after upgrading your R730, first ensure that the memory configuration is identical for both CPUs. Check for bent pins in the CPU and DIMM sockets, and test each DIMM individually. If errors persist, replace any DIMMs showing multibit errors and consider clearing logs or reinstalling memory modules. [community thread]

Can I upgrade the processor in a PowerEdge R730 to achieve a base frequency of 2.9 GHz?

The PowerEdge R730 supports the Intel Xeon E5-2680 V4 processor, which has a base frequency of 2.4 GHz. There are no compatible processors available for a base frequency of 2.9 GHz, but a 3.0 GHz option may be available. [community thread]

How can I effectively update firmware and drivers on a Dell R540 server?

To update firmware and drivers on a Dell R540 server, you can use the LifeCycle Controller, which has proven to be effective for many users. Alternatively, the Server Update Utility may provide outdated or incorrect results, so checking individual updates on the official website is recommended for the latest versions. [community thread]

What are the maximum upgrade options for a Dell PowerEdge R330 in 2024?

The Dell PowerEdge R330 can support the Intel Xeon E3-1280V6 as the most powerful CPU, with a maximum RAM capacity of 64 GB using DDR4 modules at various speeds. For storage, configurations vary, and NVMe M.2 support is not available. Additional components like specific cables and drive trays depend on your chosen configuration. [community thread]

What should I do if I receive a timeout error when connecting to the virtual console on a Poweredge R430?

If you encounter a timeout error indicating that the session has timed out waiting for certificate verification, ensure that the virtual console is enabled in the iDRAC settings. Additionally, check if port 5900 is accessible, as issues with this port can affect connectivity. [community thread]

Can I install a T620 backplane in a T630 server?

The backplane part number X4V7W is only validated for the T620 and is not compatible with the T630. While the signal cables may be similar, it is recommended to use backplanes specifically designed for the T630 to ensure proper functionality. [community thread]

What is the maximum power draw for the x16 PCIe 3.0 slot on the PowerEdge T430?

The PowerEdge T430 supports GPU cards with a maximum power draw of 300 W. Additionally, you will need to connect an extra power cable from the Power Interface Board (PIB) to the GPU. [community thread]

How can I resolve issues with updating the firmware on an Express Flash PCIe SSD in an R740 server?

First, ensure that the iDRAC firmware is current. Check the version of your SSD firmware to confirm whether you are attempting to upgrade or downgrade, as using an older version may cause issues. If problems persist, consider clearing the iDRAC logs and performing a reset. [community thread]

What cable kit do I need to install an NVIDIA RTX A5000 in a Dell R7515 server?

The required cable kit depends on the riser location for the GPU installation. For Riser #1, use part number 0M6CK, and for Riser #4, use part number GPN9K. [community thread]

Is AVX enabled by default in the BIOS of the Dell PowerEdge R740xd, and how can I enable it if it's not?

AVX is typically enabled by default, but it's advisable to check the BIOS settings to confirm. Ensure your server's BIOS and iDRAC are updated, and if AVX is not visible, consider testing with a newer version of VMware ESXi. [community thread]

Can I install an NVIDIA RTX4000 8G graphics card in a Dell PowerEdge R740xd server?

Yes, the Dell PowerEdge R740xd is compatible with certain versions of the NVIDIA RTX4000 graphics card, specifically part numbers 6NDR3 and NM0KF. [community thread]

What should I do if my Dell T630 server won't power on and shows specific diagnostic light patterns?

To troubleshoot a Dell T630 that fails to boot, start by removing all peripherals and testing each RAM DIMM individually. If the issue persists, it may be necessary to replace both the motherboard and CPU, as they are often replaced together in such cases. [community thread]

Can the R730 server be suspended to memory for low power consumption?

The R730 does not support memory suspension commands like 'systemctl suspend' or 'rtcwake', which are typically designed for laptops. As a result, attempting to suspend the server may lead to an unresponsive state without reducing power usage. [community thread]

Do the Dell PowerEdge R730 and R730xd servers support Resizable BAR technology?

The Dell PowerEdge R730 and R730xd servers do not have support for Resizable BAR technology, as they are based on the Intel Haswell architecture. For Resizable BAR compatibility, consider newer models like the R740 or R740xd, which are part of the 14th generation and later. [community thread]

Can I use an Icy Dock EZConvert to connect NVME M.2 SSDs to a PowerEdge T430 server's SAS backplane?

The Icy Dock EZConvert is designed to convert M.2 NVMe drives to U.2, not SAS, which means it may not be compatible with the T430's backplane. Additionally, Dell has not validated any NVME drives for this server model, so functionality is not guaranteed. [community thread]

How do I replace a failed hard drive in an HP DL160 Gen10 server?

To replace a failed hard drive, first ensure all data has been backed up. Power off the server for safety, remove the defective drive from Bay 3, and insert the new drive. After booting up, use the HPE Smart Storage Administrator to create a new array with the replacement disk, then initialize and format it in Windows Disk Management. [community thread]

What can I do about excessive fan noise on a DL380 Gen10 server?

To address high fan noise, consider updating the BIOS and iLO 5 firmware to the latest versions, as this may help regulate fan speeds. If the issue persists, performing a power drain on the server can temporarily resolve the noise. [community thread]

How can I resolve a Memory Management BSOD on a Proliant DL360 Gen10 server after driver updates?

To address the Memory Management BSOD, access the server's UEFI System Utilities by restarting the server and pressing 'F9' during the POST prompt. Navigate to System Configuration and then to the Array Configuration to check the status of the RAID. [community thread]

Can M.2 SSDs connected to a HPE Smart Array P816i-a SR controller be configured for RAID?

M.2 SSDs typically connect via PCIe and do not support hardware RAID through the Smart Array controller, as RAID functionality is usually managed by the operating system. While the Universal SATA card includes SATA connectors, it does not facilitate RAID with the Smart Array controller. [community thread]

Why is my additional SAS drive not being recognized by the HP DL380 Gen10 server?

Try reseating the drive in its slot or testing it in a different bay. It has been noted that some configurations may only recognize certain drives in specific bays, so placing the new drive in Bay 1 may resolve the issue. [community thread]

Why is the fan on my HPE ProLiant DL560 Gen10 server running loudly and quickly despite low activity?

This behavior may occur due to thermal management settings or firmware issues. It is advisable to update the System BIOS and iLO firmware, and if the problem persists, consider checking the server's cooling configuration and hardware components. [community thread]

What components are necessary to install an LFF cage in a Proliant ML350 Gen10 server that already has an SFF cage?

To add an LFF cage to a Proliant ML350 Gen10 server with an existing SFF cage, you will need the 874566-B21 4 LFF Hot-Plug hard drive cage. This kit includes the necessary backplane for supporting LFF drives, and no additional cables or components are required. [community thread]

What should I do if the Ethernet ports on my ML350 Gen10 server are not functioning after an improper shutdown?

Try performing a power drain and ensure that the network cables are securely connected. Additionally, update the drivers and firmware to their latest versions. If the problem continues, consider contacting support for further assistance. [community thread]

What type of disks can I use with the DL380 Gen10 server for RAID configurations?

The DL380 Gen10 server supports both NVMe and SSD drives, but compatibility for booting from NVMe drives can vary based on the specific part numbers. It is advisable to check the compatibility of the NVMe drives you intend to use to ensure they can function as a bootable RAID 10 set. [community thread]

How do I migrate and extend a RAID1 array to larger drives in an ML350 Gen10 server?

To migrate to larger drives, first replace one of the existing drives with the new larger SSD and allow the system to rebuild. Once the rebuild is complete, replace the second drive with the new larger SSD and wait for the rebuild again. After both drives are replaced, you can optionally extend the array and volume to utilize the additional capacity. [community thread]

Why is my DL380 Gen10 only recognizing one embedded SATA controller when others show two?

To troubleshoot this issue, check the cable connections and consider using a different cable if possible. Additionally, resetting the BIOS settings and clearing the NVRAM using the S6 switch may help resolve the problem. [community thread]

Is the BCM57416 10Gb OCP3 adapter in the DL360 Gen10+ prone to overheating when the server is off?

The BCM57416 adapter can become warm even when the server is powered off but connected to power, as it remains active. Operating temperatures for this adapter range from 5° to 60°C (41° to 140°F). If temperatures exceed this range, consider checking for firmware updates or consulting the manufacturer's documentation for further guidance. [community thread]

What should I do if my ProLiant ML350 Gen10 shows a memory population error after installing new RAM?

First, try re-seating the DIMMs to ensure they are properly connected. If the problem persists, swap the reported DIMMs with known working ones. If the issue continues, consider contacting support with the latest AHS logs for further assistance. [community thread]

Can I connect NHP SATA drives to an E208i-p SR controller in an ML110 Gen10 server?

According to the server's QuickSpecs, NHP SATA drives are compatible only with the S100i controller. The E208i-p SR controller is designed for hot-pluggable SATA/SAS drives, which does not include NHP SATA drives. [community thread]

What should I do if my Dell T640 server won't power on and the motherboard LEDs indicate a specific status?

The LED pattern suggests a potential 5V BP1 failure. Start by draining flea power by disconnecting all cables and holding the power button for 20 seconds, then wait for 3 minutes. After that, reseat the backplane cable connections and check for any damage, then attempt to power on the server with one power supply connected. [community thread]

What should I do if my R740 server shows no output from VGA or USB after replacing the motherboard?

To troubleshoot, ensure that you are using the Minimum to POST configuration: one CPU in socket 1, one memory module in socket A1, one power supply, and the correct control panel and cable. If the issue persists, check the cable connections as they may have been disturbed during the motherboard replacement, or consider that one of the components may be faulty. [community thread]

What should I do if my Dell Poweredge R430 shows a hardware error related to a component at bus 0 device 3 function 0?

Begin by updating the BIOS, iDrac, and RAID controller to the latest versions. If the error persists, try removing the PCI devices one at a time to identify if one of them is causing the issue. [community thread]

What does a flashing amber light on the iDRAC indicator mean after installing a hot-swappable SSD?

A flashing amber light on the iDRAC typically indicates a hardware issue, such as a faulty drive or a problem with the drive's software. It is advisable to check the iDRAC logs for any error messages and verify the health status of the newly installed SSD. [community thread]

What should I do if the LCD panel on my Dell R630 server is not displaying correctly?

To troubleshoot the LCD panel, first check the server logs via iDRAC or the Lifecycle Controller for any error messages. Additionally, inspect the server's LED indicators for hardware issues, as a faulty component may cause the LCD to show an orange notification. If necessary, ensure the LCD is not in standby mode by pressing the up or down buttons. [community thread]

What should I do if I receive a 'Correctable Memory Error Log Limit Reached' alert for a DIMM in my PowerEdge R730 server?

This alert indicates that the memory module has reached its error log limit and needs to be replaced. It is advisable to replace the affected DIMM to maintain optimal server performance. [community thread]

What should I do if my R630 server shows a sec 0033 intrusion detected message and won't boot?

To troubleshoot this issue, reduce the server to its minimum configuration by removing all components except for one CPU in socket 1, one memory module in socket A1, and one power supply. If the server successfully posts, gradually reintroduce the removed components to identify the faulty part; if it still doesn't post, the motherboard is likely the issue. [community thread]

What should I do if my Dell R930 server keeps powering off and the CPU resets automatically?

This issue may be related to memory errors exceeding the critical threshold, often linked to specific BIOS versions. To resolve it, power down the server, disconnect all cables, and perform a hard reset by holding the power button for 10 seconds. After that, update the BIOS to the latest version, ensuring to incrementally update if your current version is significantly outdated. [community thread]

Can I export and import settings if I need to replace the iDrac card on my R430 server?

Yes, you can back up the iDrac settings and other system configurations using the appropriate tools. Refer to the user guide for detailed instructions on how to export and import these settings. [community thread]

What should I do if my R730XD is incorrectly identifying itself as an R730 after a firmware update?

Verify the connection of the right ear control cable, as this may affect system identification. If the issue persists, consider replacing the cable or contacting support for further assistance. [community thread]

Why is my PowerEdge T630 not recognizing the new 1100W power supplies?

To resolve the issue, ensure that both the server BIOS and iDRAC firmware are updated to the latest versions. After updating, power off the server, disconnect all power cords, and hold the power button for 15 seconds to discharge capacitors. Reconnect the power cords to the new power supplies, wait for iDRAC to initialize, and then power on the server. [community thread]

Why are my SATA drives not being detected in a Dell T430 server?

The Dell T430 may not support Windows Server 2022, which could lead to detection issues. Ensure that the drives are properly connected and check the BIOS settings, as there may be an option that needs to be enabled for the drives to be recognized. [community thread]

How can I enable automatic NIC selection for PXE boot on Dell PowerEdge R730 servers?

To facilitate automatic selection of NICs during PXE boot, switch to UEFI boot mode, which allows for booting from multiple NICs without the need for manual reordering. However, note that UEFI supports a maximum of four NICs for PXE boot, and there is currently no option for automatic traversal of all available interfaces. [community thread]

How can I resolve the Lifecycle Controller firmware showing as 0.0 on my Dell T330 server?

To address the issue, first perform a power drain by shutting down the server, disconnecting all power and network cables, and holding the power button for at least 10 seconds. After reconnecting the cables, wait two minutes before powering the server back on. Additionally, consider resetting the BIOS to default settings and clearing the NVRAM. [community thread]

What should I do if my Dell PowerEdge C6420 server shows 'Unsupported TPM Hardware' after installing a TPM chip?

Ensure that the TPM module is compatible and has not been previously installed on another server, as it is cryptographically bound to the original system board. Check that the BIOS is updated and configured for UEFI boot mode. If issues persist, consider verifying the mainboard part number and the TPM part number without the leading zero. [community thread]

What should I do if my Dell Poweredge R840 shows a PCI1318 error after upgrading to Centos Stream 9?

The PCI1318 error may indicate a problem with the PCI bridge or the Mellanox card. You can try removing the Mellanox card to see if the error persists, check for any damage in the PCI slot, or test the card in a different slot. If the issue continues, consider that a system board replacement might be necessary. [community thread]

What is the part number for the CRTL_SRC_SB1 Cable for a Dell R550 16x2.5 SFF?

The part number for the CRTL_SRC_SB1 Cable for the Dell R550 16x2.5 SFF is 4HYC0. This cable is described as ASSY,CBL,SAS,X16,FPERC,15G,2U. [community thread]

What should I do if my PowerEdge R640 server encounters an iDRAC error after a BIOS update attempt?

Ensure that you are using the correct .exe format for your system architecture. If the BIOS update fails, perform a complete AC power cycle by shutting down the server, disconnecting all power sources, waiting briefly, and then reconnecting the power. After this, try the BIOS update again via the iDRAC web interface or the Lifecycle Controller. [community thread]

What should I do if I encounter a fatal error on my PowerEdge R430 related to bus 0 device 1 function 0?

Start by powering down the server and reseating the RAID controller, and if the error continues, try removing it entirely along with other expansion cards. Additionally, check and update the BIOS and iDRAC versions to ensure they are current. [community thread]

Is there an Internal Dual SD Module available for the PowerEdge T130?

There is no compatible Internal Dual SD Module (IDSDM) for the PowerEdge T130. The server supports an optional SD v flash card instead. [community thread]

How can I determine if a motherboard is compatible with my R730xd server?

To ensure compatibility, it's best to use a motherboard with the same part number as your original board. If you're considering a different part number, check if it is a revision or upgrade of the original, as newer revisions may offer additional features but could also lead to compatibility issues. [community thread]

Which MIB should I use to monitor my Dell R750 server?

For monitoring the Dell R750 server, you should use the latest Dell OpenManage MIBs, specifically version 11.0.1.0. You can find the updated SNMP Reference Guide on Dell's official website. [community thread]

What do I need to upgrade the second processor in a PowerEdge R730 server?

To add a second CPU to your R730, you should obtain an identical processor to the one already installed, along with a compatible CPU heatsink. Additionally, ensure that your BIOS and iDRAC are updated before installing the new processors. For more detailed information, consider searching for an R730 CPU upgrade kit. [community thread]

What should I do if my DELL PowerEdge R840 is stuck on the BIOS screen after moving it?

To resolve this issue, try booting the server with only the essential components connected, such as the power supply, motherboard, one CPU, and a single RAM stick. If the problem persists, consider reseating the RAM modules, as this has helped others successfully boot their servers. [community thread]

What cables and risers are needed to install Tesla V100 GPUs in R740XD servers?

To install Tesla V100 GPUs in R740XD servers, you will require a GPU enablement kit, specifically part numbers 330-BBMO or 490-BEIX. This kit includes various components necessary for proper installation, and it's advisable to consult the service manual for detailed installation instructions. [community thread]

How do I update the BIOS on a Dell PowerEdge R650xs server?

To update the BIOS, download the latest executable file (e.g., BIOS_T3H20_WN64_1.13.2.EXE) and run it as an administrator. A reboot will be required to complete the upgrade, and it is safe to upgrade directly from version 1.10.2 to 1.13.2. [community thread]

What BOSS S1 Cards are compatible with the R6515 10-Bay server?

For the R6515 10-Bay server, you can refer to the documentation linked for compatible BOSS S1 Cards. Specifically, check page 20 for details on the internal storage options. [community thread]

What should I do if my Dell PowerEdge T330 server is stuck before BIOS with a message about initializing SATA devices?

If your server hangs at the 'Initializing Serial ATA devices' message, consider removing the RAID controller and attempting to boot again. This step may help resolve the issue. [community thread]

How can I enable LLDP on an iDRAC 8 server?

To activate LLDP on iDRAC 8, access the iDRAC console and go to iDRAC Settings > Connectivity > Network > Common Settings > Topology LLDP. [community thread]

What should I do if my Dell R730xd shows hardware error messages related to the SATA controller and bus errors?

These error messages may indicate a common issue, likely related to the PCIe interface. First, power down the server, disconnect all cables, and hold the power button for 10 seconds. After reconnecting everything, wait two minutes before turning the server back on. If the problem persists, reseat any components in slot 5 and ensure all firmware and drivers are current. [community thread]

Can I disable a CPU on a PowerEdge R440 server without physically removing it?

There is no supported method to completely deactivate a CPU while it remains installed in the PowerEdge R440. However, you can disable individual cores of the CPU through the system settings, which may help in managing performance and costs. [community thread]

How can I identify compatible PCIe cards for external SAS ports on a PowerEdge R630?

To find suitable PCIe cards for external SAS connections, refer to the technical manual for slot preferences and supported cards. For external SAS, consider using the Dell dual-port 12G SAS adapter or the Dell H830 RAID controller, depending on your storage needs. [community thread]

What screw sizes are needed for the PERC card tray on a Dell R350 server?

The required screws for the PERC card tray are M3 x 3.6mm. You will need a total of four screws for proper installation. [community thread]

What are the GPU upgrade options for the Dell EMC PowerEdge T440?

The Dell EMC PowerEdge T440 supports GPU installation in both rack and tower configurations, provided it has a power supply of 1100 W or more. It can accommodate a single-slot GPU card with up to 32 GB of dedicated GDDR5 memory, specifically in the x16 slot (slot 3) with dual processors. Note that only active GPU cards with embedded fans are compatible, and high-power cards may require additional cooling measures. [community thread]

What does an amber light on a Dell EMC PowerEdge R440 indicate and how can I resolve it?

An amber light on the R440 typically signals a hardware issue. To diagnose the problem, access the iDRAC logs or use OMSA to gather more information about the error. [community thread]

Do I need the exact part number for a replacement R740 motherboard?

While it's important to match the part number for compatibility, there are multiple part numbers associated with the R740 motherboard. You should verify that the replacement board has the same layout and specifications as your original to ensure proper functionality. [community thread]

Can I use both riser power supplies on an R740 server to exceed the GPU's power limit?

Using both riser power supplies may not allow you to exceed the GPU's 300W power limit, as the total power capacity of the GPU is not effectively increased by connecting multiple cables. While connecting both cables is generally safe, exceeding the power limits can lead to potential damage or performance issues. [community thread]

What is the power output of the mini 6-pin connector on a R6515 server?

The exact power output for the mini 6-pin connector on the R6515 motherboard is not specified in the documentation. However, it is typically used for optical disk drives, which generally consume between 15W to 27W at 12V. To measure the output, a multimeter can be utilized. [community thread]

What components are necessary for installing an OS on a Dell PowerEdge R6525 server?

To successfully install an operating system on a Dell PowerEdge R6525, it is essential to use Dell-certified components, including a compatible CPU, RAM, and a recommended 1400W power supply unit. Non-standard or third-party parts may lead to compatibility issues and prevent the system from booting or installing the OS correctly. Ensure all components are properly connected and configured in the BIOS. [community thread]

What does a yellow warning LED on an R440 server indicate and how can I check for more details?

A yellow warning LED typically signifies that there are ECC errors logged in the system. To investigate further, clear the logs using the OpenManage Server Administrator (OMSA) and check for any BIOS or firmware updates. Additionally, accessing the iDRAC interface can provide specific alarm details. [community thread]

What should I do if my T140 server won't boot and has no video output?

To troubleshoot a T140 server that fails to boot and shows no video, ensure only the essential components are connected: the processor, one memory module in socket A1, and the power supply. If the server still does not complete POST, the motherboard may need to be replaced. [community thread]

What should I do if the HTML5 console for my R730 IDRAC8 fails to launch after a firmware update?

To resolve issues with the HTML5 console, first clear your browser's cache and see if that helps. If the problem persists, try using a different supported browser. Additionally, consider resetting the DRAC to its default settings, then reconfigure it and check if the console works. [community thread]

What cable is needed to install an Nvidia Tesla V100 in a PowerEdge R7425?

To connect an Nvidia Tesla V100 to a PowerEdge R7425, you will need a specific cable. The recommended part numbers are DPHJ8 for the PCIe GPU cable and T34N0 for the CPU to GPU cable. [community thread]

What is the required CPU wattage for running 2 GPUs in an R730 8 Bay SFF Server?

When using dual GPUs under 300W each with Dual Intel Xeon E5-3699v4 processors, it is important to check the total power consumption to ensure it does not exceed the server's power supply capacity. Refer to the server's documentation for specific wattage requirements and recommendations. [community thread]

How can I export and import iDRAC settings when replacing the card?

To transfer your iDRAC settings to a new card, you can use the iDRAC Server Configuration Profiles feature. This allows you to save your current configuration and easily restore it on the new card. [community thread]

What should I do if my T630 server is stuck on the Intel Quickpath Interconnect screen after adding a second CPU?

This issue may be related to the motherboard or configuration. To troubleshoot, ensure you have the minimum components connected: one CPU in socket 1, one memory module in socket A1, a power supply, the system board, and the control panel. [community thread]

What should I do if my R730 server hangs during POST and shows a fatal error related to the network card?

If your R730 server is freezing during POST with a network card error, try removing the network adapter to see if the server operates normally. Additionally, ensure that the server's BIOS and iDRAC firmware are updated, as outdated firmware may contribute to the issue. [community thread]

What is the part number for the 3.5-inch caddy in the T360 16th generation server?

The part number for the 3.5-inch hard drive carrier in the T360 16th generation server is WH5D2. Additionally, you will need four screws with part number Y2R90 for installation. [community thread]

Why are my Dell T160 hard drives slow and noisy?

The Dell T160 is equipped with 7.2K RPM SATA drives in a RAID 1 configuration, which can lead to performance limitations, especially during random I/O operations like file sharing. The noise and sluggishness you are experiencing are common with this type of hardware, particularly under load. For improved performance, consider upgrading to SSDs or NVMe drives, which are supported by the T160. [community thread]

Is it possible to use a T630 motherboard and components in a T6220 case?

The components from the T630 are not compatible with the T6220 case, including the motherboard. Therefore, you cannot interchange the chassis. [community thread]

What parts are compatible between Dell PowerEdge R930 and R630 servers?

The R930 shares many internal components with other 13th generation servers like the R630, but chassis-specific parts such as drive cages and motherboards are not interchangeable. For a 24-bay upgrade, you will need specific parts designed for the R930, including the 24-bay drive cage and backplane. To find part numbers, check the Dell Support website and refer to the documentation for your server model. [community thread]

How can I install 2.5" SATA drives in an R240 2 Bay LFF server?

To fit 2.5" SATA drives in the R240, you will need 3.5" to 2.5" drive tray adapters. A compatible part number for the adapter is DPN# 9W8C4, which works with various PowerEdge models. [community thread]

Why are the fans running at maximum speed after upgrading the CPU?

This issue may occur due to outdated BIOS or iDRAC/BMC firmware. Ensure that both are updated to the latest versions. Additionally, check the power supply unit's output to confirm it meets the requirements for the new CPU. [community thread]

What should I do if my Dell T330 server shows a UEFI0130 error indicating that the system time and date are invalid?

If your Dell T330 displays a UEFI0130 error, first verify the BIOS settings, ensuring the time zone and hardware clock settings are correct. If the issue persists after replacing the CMOS battery, consider checking for the correct BIOS version and exploring advanced BIOS options. If these steps do not resolve the problem, it may indicate a hardware fault, such as a failing RTC chip, which could require professional diagnostics. [community thread]

What are the PCIE plugs on the backplane of a Poweredge R730xd used for?

The PCIE plugs on the backplane are intended for specific configurations that utilize PCIe extenders and cables. It's important to note that modifications to the backplane configuration are not supported by the manufacturer, as the components may not align with the service tag and there are no available kits for such changes. [community thread]

Why do the fans in my R730xd run at high speeds when hard drives are installed?

The R730xd is known to have an aggressive fan control system that increases fan speeds when any drives are present, even if they are Dell certified. While there is no guaranteed fix, some users have found that using specific drive models, such as Dell Enterprise drives or certain Seagate and HGST models, may help reduce fan speeds. Additionally, you can consider manually adjusting fan settings through the BIOS or iDRAC to achieve a more balanced cooling profile. [community thread]

How can I securely erase all data from a Dell PowerEdge R740 server with a RAID5 array?

To securely erase data with no recovery option, you can use the Standard Disks (Overwrite Data) method, which is suitable for most drives. If the Cryptographic Erase Disks option is unavailable, it may be due to the drives not being ISE-capable or not in a Ready or Non-RAID state. [community thread]

What should I do if the iDrac on my R640 server is not responding or pingable?

If the iDrac is unresponsive, ensure that the server's operating system is compatible with the OpenManage Server Administrator (OMSA) tool, which can be installed on various platforms. If you cannot access the iDrac via SSH to run the racadm racreset command, consider having someone on-site check the physical connections or perform a hard reset of the server. [community thread]

What power connectors are compatible with the Nvidia Bluefield 3 on the PowerEdge R760?

The Bluefield 3 is not officially supported on the R760, which may lead to compatibility issues with the power connectors. For accurate information on compatible cables, it is advisable to consult the documentation or seek assistance from the community for any potential solutions. [community thread]

What is the power supply configuration needed for a Dell PowerEdge R740 with two NVIDIA A100 GPUs?

For a Dell PowerEdge R740 equipped with two NVIDIA A100 GPUs, it is essential to use power supplies rated at 1100W or higher and to configure them in non-redundant mode. Additionally, you will need to obtain the Nvidia A-Series enablement kit (PN#490-BGVQ) for proper installation. [community thread]

Can I install a GPU in an R740 server with two 750W power supplies instead of the recommended 1100W?

While the R740 server documentation specifies a minimum of 1100W for optimal GPU performance, you may attempt to install a GPU with your current 750W power supplies. However, the actual performance and functionality will depend on the specific GPU's power requirements, so testing is advised. [community thread]

What dual CPU combinations are compatible with the Dell R430 server?

The Dell R430 supports several Xeon E5-2690 V3 and V4 processors, but does not support the E5-2697A V4. Ensure your power supply and BIOS are updated for optimal performance. [community thread]

What should I do if my ML350 Gen11 is stuck in a firmware update loop?

To resolve the firmware update loop, download the latest Service Pack for ProLiant, create a bootable USB drive with the ISO, and boot the server from the USB. Use the Interactive mode to update the firmware, and if issues persist, consider resetting the HPE Intelligent Provisioning by adjusting the system configuration dip switch. [community thread]

How can I remove VID drives from a DL360 Gen10 server?

The Virtual Install Disk feature is no longer supported in Gen9 and Gen10 servers. Ensure that your iLO firmware is up to date, as this may help resolve the issue. [community thread]

How do I replace a hard drive in a DL380 Gen10 with a different capacity than the existing drives?

When replacing a hard drive, the HPE Smart Array controller will recognize the full capacity of the new drive. It is important to avoid mixing SATA and SAS drives, and ideally, the replacement drive should match the capacity of the other drives in the array to prevent issues. [community thread]

Why are no controllers detected in my HP ML 110 Gen10 server when setting up RAID?

Ensure that the correct Smart Array controller is installed, as the ML110 Gen10 typically uses the Embedded SW RAID with 10 SATA ports. Refer to the relevant documentation for guidance on configuring the HPE Smart Array S100i SR Gen10 SW RAID support. [community thread]

How can I download the BIOS firmware update for the DL20 Gen10 server?

To download the BIOS firmware update for the DL20 Gen10, use the correct link provided on the HPE website for the ROM Flash Firmware Package. If you encounter issues with cURL, ensure you have the necessary permissions or try accessing the download directly through the HPE Support Center. [community thread]

What cabling should I use for the DL380 Gen10 with a 12 LFF and additional drive bays configuration?

For the DL380 Gen10 with a 12 LFF configuration and additional drive bays, connect the rear 2 SFF option to port 8, the rear 3 LFF option to port 9, and the mid-plane 4 LFF option to port 6. For further details, refer to the relevant documentation. [community thread]

Can I use 3 rear SFF cages with the DL385 Gen10 8LFF configuration?

The DL385 Gen10 8LFF configuration is limited to 2 SFF cages due to design specifications. If you are encountering issues with the OCA tool, it may not be functioning correctly, as the system supports only 2 SFF rear drive boxes. [community thread]

Why is memory throughput limited to 10GB/s on a DL380 Gen10 with dual CPUs?

The observed memory throughput drop to 10GB/s when using dual CPUs may be a characteristic of the DL380 Gen10 model, as other systems have shown improved performance with dual CPU configurations. Users experiencing this issue should consider reviewing their memory configuration and benchmarking against other server models for comparison. [community thread]

How can I add a global spare disk to a DL380 Gen10 Plus RAID array?

To configure a global spare disk on a DL380 Gen10 Plus, access the System Utilities and navigate to System Configuration, then Controller Management. From there, select Advanced Controller Properties and enable the Persistent Spare option to designate a drive slot as a spare. [community thread]

Can I add an LFF drive cage to an HPE Proliant ML350 Gen10 server that currently has an SFF drive cage?

It is not recommended to modify a server that originally comes with an SFF drive cage by adding an LFF drive cage. Instead, consider installing an additional SFF drive cage with an expander to manage all drives using the same controller for array expansion. [community thread]

How can I disable mixed mode on the RAID controller for my DL325 Gen10 server?

The HPE Smart Array E208i-a SR Gen10 controller operates in mixed mode by default, and there is no option to turn it off. To successfully install Windows Server 2012 R2, ensure that you provide the appropriate drivers for the Smart Array Controller during the installation process. [community thread]

Is it safe to update the firmware on an HP DL380 Gen10 directly to the latest SPP version from an older one?

Before proceeding with a firmware update, check the Release Notes for any prerequisites. If the documentation specifies that an intermediate SPP version must be installed first, follow those instructions. [community thread]

How can I update the firmware on my ProLiant ML350 Gen10 server that hasn't been updated in years?

To update the firmware on your ProLiant ML350 Gen10, it is recommended to use the Service Pack for ProLiant (SPP), which allows you to upgrade all components to the latest versions in one go, avoiding the need for intermediate updates. For detailed instructions on using the SPP, refer to the available video resources. [community thread]

What should I do if my ProLiant DL360 Gen10 BIOS settings reset after a power outage?

If the BIOS settings revert to default after a power loss, it may indicate a failing CMOS battery. Consider replacing the battery, which is typically a CR2032 type, to maintain BIOS configurations. If the issue persists, check for any firmware updates or consult technical support for further assistance. [community thread]

Why are my SAS HDDs not recognized in my DL380 Gen10 server?

The DL380 Gen10's embedded S100i SR Gen10 software RAID is a SATA controller, which does not support SAS drives. To use SAS HDDs, you will need to install a compatible SAS controller. [community thread]

Can I install two full-length GPUs and one half-length capture card in a DL385 Gen10 server?

The DL385 Gen10 server typically comes with a riser that has one full-length and two half-length slots. To accommodate two full-length GPUs, you may need to explore additional riser options or configurations, as the standard setup may not support this arrangement with a single CPU. [community thread]

What should I do if I encounter an error while updating Intelligent Provisioning on a DL380 Gen10 server?

If you receive an error when trying to update Intelligent Provisioning, consider rolling back the ROM to a previous version and then performing the update incrementally. For example, downgrade from version 3.34 to 2.90, update Intelligent Provisioning to the desired version, and then reapply the ROM update. [community thread]

Are there limitations on the number of transceivers that can be used with a DL380 Gen10 Plus server configured with multiple NICs?

Yes, the DL380 Gen10 Plus has a maximum configuration limit of 14 transceivers, which may restrict the use of certain NICs that require more than this number. It is advisable to verify the specifications and compatibility of the installed components to ensure proper configuration. [community thread]

What should I do if my HP DL380 Gen10 server displays a runtime fault related to Processor 1?

If you encounter a runtime fault indicating an issue with Processor 1, it is likely that the system board requires replacement. For further assistance, consider consulting a technician. [community thread]

Why are the disk LEDs not lighting up on my HPE ProLiant DL380 Gen10 server with an MR416i-a controller?

The issue may stem from using the wrong type of drive carriers; the MR416i-a controller only supports Basic Carrier Drives, not Smart Carrier Drives. Additionally, ensure that the drive firmware is up to date and check the connections for any potential issues. [community thread]

Can the ML110 Gen11 boot from an NVMe drive installed in the mainboard slots?

The ML110 Gen11 does not support booting from NVMe drives in the mainboard slots, as they are managed by the Intel VROC tool. Additionally, using a PCIe adapter to boot from NVMe is not possible with this server model. [community thread]

What type of SATA cable is compatible with the HPE Proliant ML110 Gen10 server?

For the HPE Proliant ML110 Gen10 server, you can use a standard SATA cable for connectors 10 and 11. Alternatively, for connectors 6 and 7, an SFF8087 to 4xSATA splitter cable is recommended. If you prefer an HPE-supported solution, consider acquiring a Drive Cage as specified in the QuickSpecs. [community thread]

What should I do if my SSDs are not recognized by the DL20 Gen10 server?

Ensure that the SSDs are compatible with the DL20 Gen10 model, as non-HPE firmware drives may not function correctly. It's advisable to update the iLO and Smart Array firmware to the latest versions to improve compatibility. [community thread]

How can I update the BIOS on a DL360 Gen10 with a TPM chip without encountering installation warnings?

To update the BIOS on a DL360 Gen10 with a TPM chip, consider using the iLO Web UI for the update process. This method may help bypass the warnings associated with the TPM chip during installation. [community thread]

Why does the Smart Storage Administrator show 'No Controllers Detected' on the HPE DL380 Gen10?

Ensure that the server's controller is properly installed and recognized by the system. Additionally, check if the server is configured to use UEFI or Legacy boot mode, as this can affect controller detection. [community thread]

What should I do if my HPE ProLiant DL360 G10 does not recognize fan 7?

First, try updating the iLO firmware and ensure the fan slot is free of dust. If the issue persists, it may indicate a problem with the system board, especially if other components like PCI cards are also not recognized. [community thread]

Can I install both SSDs and NVMe drives in a DL380 Gen10 server with a 12 LFF chassis?

Yes, you can configure the DL380 Gen10 server with 12 x 3.5" LFF HDDs along with either 4 x SSDs or 2 x SSDs plus 2 x NVMe drives. For detailed specifications and support information, refer to the manufacturer's documentation. [community thread]

Why is my HP ProLiant ML110 Gen10 showing 'No Controllers Detected' in Smart Storage Administrator?

This issue may occur if the embedded S100i controller is set to SATA mode instead of RAID mode, as SSA will not recognize it in SATA mode. Check the controller settings in the BIOS to ensure it is configured correctly. [community thread]

What cable kit do I need to connect an E208i-a RAID controller to a 4LFF hot plug drive backplane in an ML350 Gen10 server?

To connect the E208i-a RAID controller to a 4LFF hot plug drive backplane in the ML350 Gen10, you will need the Embedded SATA cable kit for 4-bay LFF configuration, which includes a 470 mm long SAS cable and a 250 mm long cable. The part number for this kit is 879463-001. [community thread]

How can I reset the BIOS password on a Proliant ML 110 Gen10 server?

To reset the BIOS password, locate the System Maintenance Switch (s5) on the system board. Set the switch to the 'On' position to disable the password, then return it to 'Off' after the reset. [community thread]

What should I do if I encounter a firmware update error on an HPE DL380 Gen10 server with a 10Gb Ethernet adapter?

Ensure that the installed Ethernet adapter is compatible with the DL380 Gen10 server, as some models may not be supported. Additionally, verify that the NIC is running the minimum required firmware version (NVM Image version 216.0.333011) before attempting the update, as updates may fail if this requirement is not met. [community thread]

What should I do if my HPE DL360 Gen10 shows a memory not genuine error in the ILO GUI?

First, try reseating the memory module. If the issue persists, update the BIOS and iLO firmware to the latest versions, then restart the server. If the problem continues, replacing the system board may be necessary. [community thread]

Why is my RAID 5 volume not accessible after replacing the controller on my DL380 Gen10 server?

After replacing the controller, ensure that you have reconfigured the RAID 5 array correctly and check the disk status in Windows Disk Management. If the drive appears as unallocated or raw, you may need to import the existing volume through the controller's BIOS. Additionally, verify if the disks are in the process of rebuilding, as this can affect accessibility. [community thread]

How can I fix the iLO firmware failure on my DL380 Gen10 server?

To resolve the iLO firmware failure, download the Online ROM Flash Firmware Package for HPE Integrated Lights-Out 5, upload it to the iLO repository, and then install it from there. This method has been reported to successfully fix the issue. [community thread]

What power cord is required for the Nvidia A100x Converged Accelerator in a DL380 Gen10 server?

To ensure compatibility with the Nvidia A100x Converged Accelerator, consult the Server QuickSpecs, specifically page 64 for GPU compatibility and page 68 for graphics cable kits. Detailed information can be found in the provided technical documents. [community thread]

Why can't I set up RAID on my ML350 Gen10 server after wiping it for a new installation?

To configure RAID on the ML350 Gen10, ensure that the drive cage is connected to the E208i Smart Array controller instead of the S100i controller. After changing the storage mode in the BIOS to Smart Array, restart the server to apply the changes and check the Smart Storage Administrator for the physical disks. [community thread]

Will my RAID array function if I transfer the RAID controller and disks from an old DL160 Gen10 to a new one?

If the RAID controller is an SR type, such as an E208, the RAID configuration is saved on the drives, so moving the drives and controller should allow the RAID array to be recognized. However, be aware that the operating system currently installed may present compatibility issues. [community thread]

Does the HP DL380 Gen10 with a 24 SFF chassis come with all necessary cabling for additional drives?

The DL380 Gen10 chassis includes the drive cage for 24 SFF bays, but to utilize more than 8 drives, a SAS expander is required. Additional cabling will need to be connected after installing the SAS expander. [community thread]

Why are my SAS drives not recognized during OS installation on a DL380 Gen10 server?

The S100i storage controller only supports SATA drives, which may be why your SAS drives are not detected. To use the SAS drives, you will need to install a compatible RAID controller that supports them. [community thread]

What should I do if my ProLiant DL380 Gen10 shows a new drive as Degraded (Not authenticated)?

Verify that the Smart Carrier Backplane is not obstructed by covers over the Smart Carrier pins, as this can prevent drives from being recognized properly. If necessary, remove any covers and reinsert the drive to see if the issue is resolved. [community thread]

How do I connect a video card to an ML350 Gen10 server?

To connect a GPU in the ML350 Gen10 server, you will need the HPE ML350 Gen10 GPU external power cable kit (877628-B21) and the HPE ML350 Gen10 redundant fan cage kit (874572-B21). For detailed instructions, refer to the official HPE support documentation. [community thread]

Why are the fans running at 45% speed on my DL20 Gen10 server with AHCI configured?

This fan speed may be a normal behavior when using AHCI mode, as it can lead to more aggressive fan management. To troubleshoot, ensure that there are no blank slots and check the ambient temperature of the server room. If the issue continues, consider testing with a compatible add-on controller or contacting support for further assistance. [community thread]

What should I do if my firmware update fails on a Dell R750 server?

To resolve firmware update failures, consider creating a bootable USB drive using a third-party tool such as Rufus or UltraISO with the appropriate ISO file. Alternatively, you can use the Server Update Utility (SUU) from the Dell Repository Manager to facilitate the update process. [community thread]

What graphics cards are compatible with the Dell PowerEdge R730 server?

The Dell PowerEdge R730 supports specific GPUs rather than standard graphics cards. Ensure that the power supply is adequate for the GPU's requirements, and verify that the server's BIOS is updated for compatibility. [community thread]

What is the part number for the R6515 700W power supply?

The part number for the R6515 700W power supply is 825J5. [community thread]

Which PowerEdge servers support U.3 interfaces?

The Dell Scalable Solutions versions of the R7515, R7525, and R7615 are the only models that currently support U.3 drives. [community thread]

Can I connect NVMe drives to a PowerEdge R7515 with a 3.5-inch backplane?

The 3.5-inch backplane in the PowerEdge R7515 does not support NVMe drives. To use NVMe drives, you will need to replace the backplane with one that is compatible with NVMe and ensure that you have the correct controller. [community thread]

What should I do if my PowerEdge T330 BIOS update is hanging during the process?

If the BIOS update appears to be stalled, it may be necessary to perform a cold boot of the server. After rebooting, monitor the system for multiple restarts, which can indicate that the update is completing; check the iDRAC job queue afterward to confirm if the update was successful. [community thread]

Why is there no video output from the mini DisplayPort on a Dell C6420 server?

If you're experiencing no video from the mini DisplayPort, ensure you are using a compatible adapter, as some may only support analog output. It's recommended to try a mini DisplayPort to VGA adapter, as this has been noted to work with certain configurations. [community thread]

Why is my Dell T360 server making excessive noise?

High noise levels in the Dell T360 can be caused by the installation of components like a BOSS controller or GPU, which may trigger increased fan speeds for cooling. It's advisable to check the iDrac settings for cooling configuration and ensure that all firmware is updated. [community thread]

Can I safely power an A30X GPU using a specific cable with an R750 server?

Yes, the DELL cable 0T34N0 can be used to connect the A30X GPU to the R750 server, as it is compatible with the required power connectors. However, compatibility with the A30X has not been explicitly tested, so proceed with caution. [community thread]

What cables are needed to install 4 GPUs in a PER760XA server?

To install 4 GPUs in a PER760XA server, you will require a GPU enablement kit (part number 470-BCTG) along with several specific cables: 0T07W (Left GPU cable), 191JG (CPU GPU PUCK cable - Black), 7V563 (Right GPU cable), M88NN (GPU PUCK cable - Gray, 12 Pin), XYDKX (GPU PUCK cable - Black, 12 Pin), and YHF7N (CPU GPU PUCK cable - Gray). Ensure you have all these cables for proper installation. [community thread]

How can I check the current CPU and memory usage of my R930 server using SNMP?

To check CPU and memory usage on your R930 server via SNMP, ensure that SNMP is enabled in the iDRAC settings and that you have the correct community string. Use the appropriate OIDs for CPU (1.3.6.1.4.1.674.10895.3000.10.1.1.1.5) and memory (1.3.6.1.4.1.674.10895.3000.10.1.1.1.6) with an SNMP tool like snmpget or snmpwalk to retrieve the data. [community thread]

What should I do if my R740XD's iDRAC is unresponsive and the VGA displays vertical lines?

You may need to replace the motherboard if the iDRAC is not functioning and the VGA shows vertical lines. Before proceeding with a replacement, try rebooting the iDRAC, performing a flea power drain, and clearing the NVRAM. If these steps do not resolve the issue, consider seeking professional support. [community thread]

Is the R440 server compatible with 64GB RDIMMs?

The R440 server can technically support 64GB RDIMMs, but only with Gen 2 CPUs. However, for optimal performance, it is recommended to use 32GB RDIMMs instead. [community thread]

What should I do if my R7515 server doesn't post and the ds3 and ds4 lights are on?

Check the power supply connections and ensure they are properly seated. If the issue persists, consider testing with a different power supply or connecting the server directly to a wall outlet instead of a UPS. Additionally, verify the minimum configuration required for the server to post. [community thread]

How can I resolve SUU failures on my PowerEdge R740xd server?

To address SUU failures, you can manually download and install the necessary updates from the Dell support site for the PowerEdge R740xd. Alternatively, you can use the LifeCycle Controller by booting the server, pressing F11, and selecting 'Platform Update' to run updates from a mounted ISO file. [community thread]

What should I do if my refurbished server shows a backplane connection error?

If your server indicates a backplane connection error, ensure that all necessary cables from the motherboard to the backplane are securely connected. If the issue persists, refer to the manufacturer's documentation for troubleshooting steps or check for similar configurations to verify cable connections. [community thread]

Why won't my Dell PER7525 server boot with two AMD 7543P CPUs installed?

The issue may stem from the AMD 7543P processors being designed primarily for single-socket configurations. It is advisable to verify compatibility with the server's specifications, as certain CPUs may not function correctly when two are installed. [community thread]

What spare parts are needed to install a second CPU in a Dell PowerEdge R540 server?

For adding a second processor to a Dell PowerEdge R540, the necessary components include a radiator, a processor bracket, and a fan. The parts KG4MM, H3H8Y, and XPDVP are compatible with the R540, but note that KG4MM is only suitable for x8 or x12 HDD configurations. [community thread]

What should I do if my DL560 Gen10 firmware update fails with exit status 7?

Ensure that you first upgrade the firmware to version 5.61, as this is necessary to enable the PLDM firmware update functionality. Once that is completed, you can then use the FWPKG file to update directly to version 6.22 or later through iLO without needing an operating system. [community thread]

Why can't I create a RAID array on my DL380 Gen10 server?

The inability to create a RAID array may stem from insufficient physical space or unrecognized drives by the RAID controller. Ensure that the drives are not part of another RAID configuration and are properly connected. You can also restart the server and access the RAID configuration utility during the POST process to set up the array. [community thread]

What should I do if the drive LED indicators on my HP Proliant DL380 Gen10 are not functioning?

Ensure that both the controller firmware and drive firmware are up to date, as outdated firmware can prevent the LEDs from illuminating. If the issue persists after updates and none of the drives show any LED activity, there may be a problem with the controller or backplane, and it is advisable to contact support for further assistance. [community thread]

Can I add drives to a RAID 5 array on a Proliant DL360 Gen10 while the system is running?

It is recommended to power down the server before adding new drives to ensure compatibility with the RAID controller. Additionally, always back up your data prior to making any changes to the storage configuration. [community thread]

What should I do if my HP DL360 G10 Plus server shows a critical fault related to memory after changing the workload profile?

The issue may stem from either the memory modules or the processor. It is advisable to open a support case with HPE for assistance in diagnosing the faulty component through log analysis. [community thread]

What should I do if my HPE Proliant DL360 Gen10 shows a power on fault with storage backplane errors?

To address a power on fault with storage backplane issues, first check the iLO logs for any critical errors. Ensure that the system firmware is up to date, and attempt to power on the server with minimal components. Additionally, verify that the power supply backplane and system board are functioning properly. If the issue persists, consider contacting HPE support for further assistance. [community thread]

What is the recommended DIMM configuration for a DL380 Gen10 server with dual Intel CPUs?

Consult the 'HPE ProLiant Gen10 Plus Servers - Part Number Memory Matrix' document for guidance on memory configuration. Additionally, check the 'DIMM-processor compatibility' section in the DL380 Gen10 Server's User Guide for detailed compatibility information. [community thread]

Why can't my ProLiant DL325 Gen10 Plus v2 detect new NVMe drives?

Ensure that the internal cabling is correctly configured, as improper connections can prevent NVMe drives from being recognized. Refer to the server's maintenance guide for detailed cabling instructions, and verify that you are using the appropriate cabling for the NVMe drives. [community thread]

Why are my Nvidia A40 GPUs showing as unknown devices on my DL380 Gen10 Plus server?

To resolve the issue, update the iLO firmware, as there are known fixes for Nvidia cards. Additionally, ensure that all installation requirements outlined in the relevant documentation are met. [community thread]

What can I do if my HPE DL380 Gen10 server's fans are running excessively fast?

If your server's fans are consistently operating at high speeds, verify if any recently installed network cards may be contributing to the issue. Additionally, ensure that all firmware is up to date and consider checking the cooling profile settings. [community thread]

How can I set a logical drive as the boot volume in a DL380 Gen10 server after installing a new RAID controller?

To configure a logical drive as the bootable volume, reboot the server and press F9 to access the BIOS/RBSU setup. Navigate to System Configuration, then to Controller, and select the option to set the Bootable Device for Legacy Boot Mode, where you can choose the logical drive to set as either the Primary or Secondary Bootable Device. [community thread]

Why aren't the drive indicators lighting up on my HP DL380 Gen10 server?

The drive LEDs may not illuminate if the drives are not part of a RAID configuration. If the drives are configured correctly in RAID, check the advisory regarding HPE Smart Array controllers, which notes that LEDs may not be lit when connected via an expander. Ensure all firmware is up to date and consider reseating the drives and connections. [community thread]

What should I do if my SR530 shows a sensor phy presence error after changing the jumper position?

To resolve the sensor phy presence error, revert Jumper 29 to Pins 1-2 as it was originally. Then, perform an AC power cycle by disconnecting power for 10 seconds before turning the system back on. If the issue continues, consider updating the system firmware and checking for alerts in XCC and vSphere. [community thread]

How can I reset a Lenovo SR630v2 server without access to BIOS or Xclarity credentials?

To reset the server, you can try removing the CMOS battery from the motherboard for an extended period, or look for a CMOS jumper to reset the BIOS settings. If those options are unavailable or ineffective, check for any switch blocks on the motherboard that may assist in the reset process. [community thread]

Why are my NVMe U.3 disks not functioning in my server?

The NVMe U.3 drives require a direct PCIe x4 connection to the motherboard, rather than routing through the SAS/SATA RAID controller. Ensure that the backplane ports for the NVMe disks are configured to use PCIe lanes x4, while the SAS/SATA devices can utilize the RAID controller. [community thread]

Can I install a GPU in a Lenovo SR650 server, and what are the compatibility requirements?

Yes, the Lenovo SR650 server can accommodate GPUs, specifically models like the NVIDIA Tesla or Quadro series. Ensure that your server has sufficient power supply, available PCIe slots, and adequate cooling for the GPU. For a detailed list of compatible GPUs and installation guidance, refer to the product's hardware manual. [community thread]

What is the AC input voltage range for the ThinkSystem SR655 v3 750W power supplies?

The ThinkSystem SR655 v3 750W power supplies are designed to automatically sense dual voltages, supporting both 110V AC (100-127V 50/60 Hz) and 220V AC (200-240V 50/60 Hz). Therefore, they can operate with 208V AC at 60 Hz. [community thread]

What should I do if the LXCI bundle 4.3.0 is not compatible with my SR850 server?

This issue may stem from a catalog mapping problem. You can try using an older firmware bundle that was previously compatible, verify the LXCI catalog sync, rescan the inventory to ensure the server model is correctly detected, or clear the client cache and restart services. If the problem persists, consider using alternative methods for firmware updates or contact technical support for assistance. [community thread]

How can I enable Above 4G Decoding and Resizable BAR on the Lenovo ThinkSystem SR665 for HPC applications?

The Lenovo ThinkSystem SR665 is primarily designed for server-grade GPUs, and features like Above 4G Decoding and Resizable BAR may not be supported for client GPUs due to hardware limitations. Upgrading to EPYC 7003 processors may improve PCIe capabilities, but it will not enable unsupported UEFI/BIOS features. For updates on firmware enhancements, check the Lenovo Support Website or contact support directly. [community thread]

Why do the disks appear inverted in Windows Server 2022 compared to the RAID controller configuration?

This is a known behavior in Windows Server 2022 where the operating system may display disk order differently than what is configured in the RAID controller. This discrepancy occurs because Windows enumerates devices based on their response time during initialization, not the RAID firmware's numbering. [community thread]

What is the performance difference between direct CPU PCIe connections and retimer connections for NVMe drives in the Lenovo ThinkSystem SR655 V3?

Direct CPU PCIe connections typically provide lower latency and more stable bandwidth compared to retimer connections. While retimers can support additional drives, they may introduce slight latency; however, for most applications, the performance difference is negligible. [community thread]

Do any servers support hot-swap CPU functionality?

Currently, Lenovo ThinkSystem servers, including the SR950, do not offer hot-swap CPU capabilities, meaning that the server must be powered down to replace CPUs. This feature is not widely available in most server designs. [community thread]

What compatible NIC can I use for the SR250 V2 server?

The SR250 V2 server supports network interface cards (NICs) rated at 1, 10, or 25 GB, but does not support 2.5 GB NICs. For a complete list of compatible NICs, refer to the manufacturer's documentation. [community thread]

What hard drive model is compatible with a Lenovo ThinkSystem SR250 V3 for adding 80TB of storage?

To achieve an additional 80TB capacity, consider using Lenovo-supported large-capacity 3.5-inch hot-swap HDDs in the available bays, ensuring your RAID controller and backplane can support them. You may need multiple high-capacity drives, such as four 20TB drives, depending on your server's configuration. [community thread]

What does it mean when the monitoring system indicates that a RAID controller resource is disabled on an SR650 v3 server?

If the XCC shows no errors and everything is green, it may be a false alert from the monitoring system. It is advisable to contact the monitoring software provider to verify if there is an actual issue. [community thread]

What are the limitations of the VROC RAID Controller for the ThinkSystem SR630 V3?

The VROC RAID Controller may have compatibility issues with certain virtualization hypervisors when using SATA RAID, while NVMe RAID is generally supported. Ensure that the Intel VROC Premium license is valid and that you are using compatible drives. It is also advisable to keep the system firmware updated and verify the RAID array in the BIOS after any rebuild. [community thread]

Is the Intel B50 Pro and Resizable BAR supported on the SR665 V3 server?

Currently, the Intel B50 Pro and Resizable BAR are not supported on the SR665 V3. Future support for these features may be announced in product guides or firmware release notes, so it's advisable to regularly check the relevant documentation for updates. [community thread]

Can I use different types of storage devices to create a RAID 5 configuration on the SR650 V3 server?

Generally, RAID controllers do not allow the combination of different storage types, such as SAS SSDs and SATA HDDs, in a single RAID array. As an alternative, you can set up your drives as JBOD and utilize software RAID solutions to create a RAID 5 array, or consider creating separate RAID arrays for each type of drive to maintain performance and reliability. [community thread]

Is it safe to upgrade from TPM 1.2 to TPM 2.0 on the ThinkSystem SR590?

Upgrading from TPM 1.2 to TPM 2.0 will erase all data in the TPM, which is standard behavior. Ensure that your ESXi encryption mode is set to NONE and Secure Boot is disabled before proceeding. It is advisable to update the firmware first, confirm the server supports TPM 2.0, and have a backup of your ESXi host configuration ready. [community thread]

What should I do if my SR630 V3 server is stuck in a reboot loop after installing drivers?

To resolve the reboot loop, first power off the server and disconnect it from AC power for about 30 seconds. If the issue persists, try disabling pending updates or booting into Safe Mode to uninstall the UpdateXpress utility. After addressing the loop, perform an offline firmware update using a bootable ISO and then install the drivers in the correct order. [community thread]

Can I use non-Lenovo Solidigm D7-PS1010 and D7-PS1030 NVMe U2 Gen5 drives in a SR655 V3 server?

While you may be able to install these drives, their compatibility is not guaranteed, and firmware updates cannot be performed through XCC. Additionally, if any issues arise, warranty coverage may not apply. [community thread]

How can I resolve the 'Status: Offline' issue for my ThinkSystem SR630 V3 servers in XClarity Administrator?

Ensure that the firmware on the Baseboard Management Controllers (BMC) of the servers is up to date. Additionally, verify that the servers are connected to the same dedicated subnet without any firewalls that could block communication. [community thread]

Why are the drives not visible during installation on the SR655 V2 server?

Ensure that the drives are properly seated and that the backplane and RAID controller connections are secure. Check the RAID controller settings to confirm that the drives are initialized and assigned to a RAID array, as unconfigured drives may not be detected by the operating system. [community thread]

What should I do if my ST550 server powers on but shows no display and has an orange LED lit near the PCIe slot?

First, ensure that the CPU installed is compatible with the ST550 and is properly seated. If the issue persists, try reseating all components, including RAM and motherboard connections, and remove any unnecessary PCIe devices. Additionally, clearing the CMOS may help reset the BIOS settings and resolve the startup problem. [community thread]

What should I do if my RAID 5 array shows multiple disks as UBAD?

First, ensure that you back up your data to prevent potential loss. Then, check for any firmware updates for your system and perform a power cycle by turning off the server and unplugging it for a short period. If the issue persists, review the logs for any errors and consider reaching out to support with the gathered information. [community thread]

How can I rebuild a degraded RAID 1 on a ThinkSystem SR630 after replacing a failed M.2 drive?

To rebuild the RAID 1 array, ensure that the replacement M.2 drive matches the original drive's specifications, particularly in size and type. Once the compatible drive is installed, boot the system, and the RAID should automatically start rebuilding, which can be monitored in the BIOS or the XClarity Controller. [community thread]

Can I install different types of fans in the ThinkSystem SR630 V2 server?

It is not advisable to mix different types or amperages of fans in the ThinkSystem SR630 V2, as this can lead to critical fan mismatch errors and increased noise levels. Only use Lenovo-supported fan modules of the same type, either all Standard or all Performance, to ensure proper operation. [community thread]

What should I do if I encounter a PSU mismatch error on my Lenovo ThinkSystem SR630 server?

To resolve the PSU mismatch error, first ensure that all power supply units (PSUs) are of the same model and firmware version, as using mismatched units can lead to errors. Additionally, check that your server's firmware, including the XClarity Controller, is updated to the latest version. If the problem continues, consider performing a power cycle and clearing the error logs. [community thread]

How can I log in directly to the XClarity Controller without being redirected to XClarity Administrator?

To bypass the redirection to XClarity Administrator when accessing the XClarity Controller, you can disable the single sign-on feature. Detailed instructions for this process can be found in the Lenovo support documentation. [community thread]

How can I control the fan speed on my SR655 V2 server that is running at 16K RPM continuously?

To manage the fan speed, first ensure that all airflow components, such as the CPU air shroud and drive bay fillers, are correctly installed. Check for any third-party hardware that may be causing high fan speeds, and verify that both power supplies are functioning properly and matched in specifications. Additionally, review the XCC logs for any thermal or sensor errors and confirm that all firmware is up to date. [community thread]

Are the FC HBA part numbers 01CV830 and 01CV832 interchangeable for the SR630 server?

Yes, both part numbers refer to the same functional component, with 01CV832 being a later revision of the original 01CV830. No action is needed, as they are supported the same way in the SR630 and utilize the same firmware and driver packages. [community thread]

Why is my ST650 V3 server making loud fan noises while idling?

The ST650 V3 is designed to operate with noticeable fan noise even when idle, particularly in configurations with high GPU or storage usage. Factors such as ambient temperature, dust accumulation, and proper installation of components can influence fan speed. Ensure the server is in a suitable environment and that all components are correctly installed to potentially reduce noise levels. [community thread]

Why are the fans on my ST550 server running at maximum speed despite low temperatures?

Fan speed on the ST550 is automatically controlled by the XClarity Controller and may run at high RPM due to sensor issues or hardware conditions. To troubleshoot, ensure all components are properly seated, check the system health and logs in XCC for any faults, and consider performing a power cycle of the BMC. If the issue persists, collect the XCC event log and contact support for further assistance. [community thread]

What should I do if my firmware bundle update fails using the XCC Redfish API on a ThinkSystem SR635 V3?

The failure may be due to using an incorrect firmware package type; ensure you are using .uxz, .exi, or signed component .zip files instead of the full bundle ZIP. Additionally, consider updating individual components using the 'multipart/form-data' method, and verify that the firmware file is not corrupted. [community thread]

What does it mean when a Drive 0 Mismatch alert shows as critical after creating a RAID 5 array?

A critical mismatch alert typically indicates issues such as unsupported drive types, uninitialized parity, or foreign configurations on the drives. To resolve this, ensure all drives are compatible, update firmware, clear any foreign configurations, and recreate the RAID array with full initialization. If problems persist, check for hardware issues or collect logs for further analysis. [community thread]

How do I perform a DC cycle for the XCC firmware update on my SR650 server?

You can initiate a DC cycle by using the BMC/XCC interface to either restart the server immediately for a hard reset or power it off and then back on for a more complete cycle. There is no need to unplug any cables. [community thread]

How can I access the SMBUS device on an AMD SR655 server?

To access the SMBUS device, ensure you are using the correct commands with ipmitool. If the command to change the I2C channel does not return the expected value, it may be due to firmware restrictions. Consider using Linux with /dev/i2c-* for direct access instead. [community thread]

What should I do if I encounter an SSL CA certificate error while refreshing the catalog in LXCA for my SR630 V3 server?

To resolve the SSL CA certificate error, ensure that your LXCA is updated to the latest 4.3.0 version and verify that your NTP settings are accurate. Additionally, check the trusted CA certificates in LXCA, ensuring that the complete chain is imported correctly and marked as trusted. If issues persist, consider using an offline repository for firmware updates. [community thread]

How can I update the firmware on a Lenovo ThinkSystem SR650 V2 that is stuck on factory versions?

If your SR650 V2 is running pre-production firmware, standard update methods may fail due to build ID mismatches. Contact Lenovo technical support to request the 'SR650 V2 Bridge Firmware Package' for transitioning from pre-GA to GA firmware, which should enable you to proceed with standard updates. [community thread]

Does the part number matter when replacing a motherboard for a Poweredge R740xd?

Yes, the part number is important as it can indicate differences in supported processors, performance revisions, and compatibility with other components. It's advisable to verify the exact part number and consider any updates or revisions that may affect compatibility. [community thread]

How do I enable VT-d for virtualization on a Dell Poweredge T440?

To enable VT-d on the T440, simply activate the 'Virtualization Technology' option in the UEFI/BIOS settings. This will automatically enable VT-d if your processor supports it. Ensure that your BIOS and iDrac are updated for optimal performance. [community thread]

How can I identify a device associated with a specific bus, device, and function number on a server running VMware ESXi?

To find the device at Bus 64, Device 3, Function 0, export the Hardware Inventory as an XML file from iDRAC. Open the XML in a text editor and search for entries labeled <PCIDevice> that match the bus, device, and function numbers. Alternatively, if you have access to the ESXi shell, you can use commands like 'lspci -v' or 'vmkchdev -l' to locate the device. [community thread]

Why did my servers shut down unexpectedly during a power outage despite having redundant power supplies?

The servers likely received a shutdown command from the UPS, which can occur if the UPS detects a power issue, even if it is still supplying power. It's important to investigate the UPS settings and logs to understand why it initiated the shutdown prematurely. [community thread]

Does the Dell PowerEdge R730 support PCIe bifurcation for NVMe AIC SSDs?

Yes, the R730 does support PCIe bifurcation, but it must be enabled in the BIOS. To do this, access the BIOS during boot, navigate to the PCIe settings under the Advanced tab, and enable the PCIe Bifurcation option, configuring it to the required x4x4x4x4 settings. [community thread]

How can I upgrade my RAID1 OS drives without losing data or reinstalling the operating system?

To replace your RAID1 drives, use the 'Replace Member Disk' option in Dell OpenManage Server Administrator (OMSA). Replace each drive one at a time, allowing the RAID to rebuild, then reconfigure the virtual disk and expand the filesystem using your OS's disk management tools. [community thread]

Can I install a Nvidia T600 GPU in a Dell PowerEdge R630 server?

The Nvidia T600 GPU (part # 4FKFP) is not officially supported for the PowerEdge R630. Compatible options for this server include the Nvidia Tesla M4 (75W) and the Intel Phi 3 (300W). [community thread]

What should I do if my PowerEdge R750xs shows lights but won't power on?

To troubleshoot a PowerEdge R750xs that fails to power on, start by removing all components except for one power supply, the system board, the power interposer board, one processor in socket 1, and one memory module in socket A1. If the server still does not power on, try swapping the power supply with a known working unit. If the issue persists, it may indicate a fault with one of the remaining components. [community thread]

Why can't I access all OIDs under the baseboardGroup node via SNMP on my R930 server?

Access to the baseboardGroup OIDs may be hindered by slow device response times. Ensure that the server is functioning properly and try again, as some hardware information may still be accessible through the outOfBandGroup. [community thread]

Can I use a multi NVMe PCI card in an R630 server?

The R630 does not support PCIe bifurcation, which means it cannot utilize multiple NVMe drives on a single card effectively. If you are only seeing one drive recognized, it is likely due to this limitation. Ensure that your firmware is up to date, but be aware that the server's design restricts the use of multi-NVMe cards. [community thread]

How can I update the System CPLD on a Dell R350 server if DSU does not provide applicable updates?

DSU does not support updating the System CPLD on PowerEdge servers. To perform the update, you can use the iDRAC web interface by selecting the downloaded CPLD update package for installation during the next reboot, or use the Lifecycle Controller by booting into it and applying the update from an FTP, network, or USB source. [community thread]

What chassis should I choose for a Dell R760 server with specific RAID configurations?

The recommended chassis is the 2.5" option that supports up to 16 drives, including 8 SAS/SATA and 8 NVMe with two internal PERC RAID controllers. When configuring, select 'unconfigured RAID' to see all available options for your desired RAID levels. [community thread]

Why can't I see any disks in the RAID configuration on my R730xd server?

Ensure that the SATA mode is set correctly in the BIOS; switching it back to the appropriate RAID controller setting may resolve the issue. If a hardware RAID controller like the H730 is installed, verify that it is properly configured and not conflicting with any software RAID settings. [community thread]

Why are 64GB DIMMs showing as unsupported in the Proliant DL380 Gen10?

To resolve the unsupported DIMM issue, first update the server's BIOS using the iLO interface. After updating, reseat the memory modules and enable memory remapping in the BIOS settings to ensure all memory is recognized. [community thread]

Why are my Seagate drives not detected by the ML350 Gen11 servers?

The ML350 Gen11 servers require drives with an HPE digital signature for detection. If the drives do not have this signature and are not listed in the supported drive documentation for your server, they will not be recognized. [community thread]

Why is my ML110 Gen10 motherboard not updating the firmware past version 1.0.8?

The issue may be related to the server case rather than the motherboard itself, as firmware updates can be affected by the power supply or other components. Try swapping the motherboard with another server case to see if it updates correctly there, as this has resolved similar problems for other users. [community thread]

Why can't I set up RAID 5 on my ProLiant DL380 Gen11 with the MR216i-o controller?

The MR216i-o controller only supports RAID levels 0, 1, and 10, which is why RAID 5 is not an available option. For RAID 5 functionality, a different controller, such as the SR controller, would be required. [community thread]

How can I upgrade the Smart Array firmware on a DL380 Gen10 from version 1.99 to 7.11?

To upgrade the Smart Array firmware, download the latest Service Pack, which includes the necessary updates. Boot from the Service Pack and allow it to update the RAID controller and other components. After the initial update, reboot and run the Service Pack again to complete the upgrade to version 7.11. [community thread]

Why are the fans on my ProLiant DL380 Gen10 running loudly?

Loud fan noise can be caused by high system temperatures, a failing fan module, or outdated firmware. Check the ambient temperature and ensure all fans are functioning properly, and consider updating the firmware to the latest version to resolve any potential issues. [community thread]

How can I check the status of the system battery on a DL380 Gen10 server remotely?

To check the system battery status remotely via iLO 5, you can look for error messages in the Integrated Management Log (IML) or monitor for any alerts regarding system health. If the battery is failing, you may notice incorrect date and time settings or BIOS configuration resets. For a physical check, a technician on-site can measure the battery voltage with a multimeter or replace the battery if necessary. [community thread]

Is the HPE Proliant DL380 Gen10 Plus compatible with the power supply part numbers 865412-201 and 865414-B21?

Yes, the power supply part numbers mentioned are compatible with the HPE ProLiant DL380 Gen10 Plus server, as they belong to the HPE Flex Slot power supply family. However, ensure that if using two power supplies, they are of the same wattage and type, and validate the power requirements against your server's configuration. [community thread]

Can I connect a second controller to the HP 12G SAS Expander on a DL380 Gen10 server?

Port 9 on the expander is a downstream port, not suitable for connecting a second controller. All drives must be managed by a single controller, so if you want to use two controllers, consider configuring them on an unconfigured system to assess drive visibility. [community thread]

What can I do if my ProLiant DL380 Gen11 fans are excessively loud after a firmware upgrade?

If your ProLiant DL380 Gen11 fans are running loudly after a firmware update, check for any available BIOS updates. Installing a newer BIOS version may resolve the issue and reduce fan noise. [community thread]

How can I reduce the noise from the fans on a DL320 Gen11 server?

To decrease fan noise on the DL320 Gen11, ensure that the latest Service Pack for ProLiant (SPP) is installed, as this can help manage fan speeds effectively. If the issue persists after installation, check for any additional drivers or updates that may be affecting fan control. [community thread]

Can I replace HDDs with SSDs in a DL380 Gen10 server without downtime?

Directly swapping HDDs for SSDs in the same RAID array is not supported due to compatibility issues. For a successful upgrade, it's recommended to back up your data, remove the HDDs, install the SSDs, and then create a new RAID array, or add SSDs alongside HDDs for a separate RAID configuration. [community thread]

Can I directly boot the latest SPP ISO to update firmware on a DL380 Gen10 running very old firmware?

It is advisable to first update the iLO firmware manually before using the SPP ISO, as this ensures a smoother upgrade process. For servers with significantly outdated firmware, consider incrementally updating to the required versions before proceeding to the latest release. [community thread]

Can I replace the internal RAID controller in an HPE ProLiant DL360 Gen10 without losing my data?

Yes, you can replace the internal RAID controller, as the RAID configuration is stored on both the controller and the disks. However, it is advisable to back up your data before proceeding with the replacement. [community thread]

What type of disks are compatible with the DL380 Gen10 server for RAID 0 configuration?

For optimal performance in a RAID 0 setup on a DL380 Gen10 server, consider using high-speed SSDs or enterprise-grade HDDs that support high read/write speeds and IOPS. Ensure that the disks are compatible with the server model to avoid any issues. [community thread]

What power cable is needed to connect a GPU to the HPE ML350 Gen11 server?

To connect a GPU to the HPE ML350 Gen11, refer to the QuickSpecs document for supported graphics cards and their corresponding power cables. If your specific GPU model is not listed, you may need to try compatible GPU power cables that fit the available connectors on the server. [community thread]

Can I change the display mode of the Nvidia L40 GPU in a DL380 Gen11 server?

Yes, the Nvidia L40 GPU in the DL380 Gen11 can utilize the Nvidia displaymodeselector software to switch the display mode from Display Off to Display On. However, it's advisable to consult with the system OEM before making any changes to avoid potential damage. [community thread]

How can I resolve the missing 'Base System Device' driver on an HPE ProLiant DL20 Gen10 server?

To fix the missing 'Base System Device' driver, download the iLO 5 ASR driver (cp060559.exe) for Microsoft Windows Server 2016 and 2019 from the official HPE website. This driver should address the issue related to the device identified by DEV_3306. [community thread]

Can I install the Online ROM Flash Component on an HP DL380 Gen11 if a TPM is detected?

You can proceed with the installation despite the TPM warning, as it is a common practice. Additionally, the Online ROM Flash can be applied through iLO, but you will need a different package for that process. [community thread]

How do I connect multiple drive cages to the RAID controller in an ML350 Gen12 server?

To connect two drive cages to the RAID controller, ensure you have the correct cage model, as the P72316-B21 may not be compatible. You should use the P72318-B21 cage with the MR416i-p controller, which supports two ports—each connecting to one cage. The necessary cable for this setup is typically included with the server. [community thread]

Why are the fans in my HP DL320 Gen11 running at high speeds even when the server is idle?

Fans in the HP DL320 Gen11 may operate at elevated speeds due to thermal settings or firmware configurations. Ensure that the latest firmware is installed and check BIOS settings for fan control options. If issues persist, consider consulting the manufacturer's support resources for further troubleshooting. [community thread]

Why are my Intel P4510 U.2 NVMe drives not achieving full width in the HPE ProLiant DL325 Gen10 Plus v2?

The HPE UBM3 backplane is incompatible with Intel P4510 drives, resulting in a downgraded link width. To resolve this, consider using U.2 NVMe PCIe adapters in the PCI slots, which can allow the drives to negotiate a full x4 width. [community thread]

What can I do about excessive fan noise in the ML110 Gen11 server?

If you're experiencing loud fan noise with the ML110 Gen11, it may help to check the server's cooling settings and ensure that all components are properly seated. Additionally, consider updating the firmware or adjusting the fan speed settings in the BIOS to see if that reduces the noise. [community thread]

What issues are commonly reported with HPE Gen12 servers?

Users have noted occasional alerts for nonvolatile memory corruption and difficulties with iLO security features, which have become more restrictive. While these issues can arise, they are not indicative of a widespread problem across all Gen12 servers. If persistent faults occur, it is advisable to pursue replacements or escalate the matter with your supplier. [community thread]

What is the user token USB key required for firmware updates on ProLiant DL380 Gen10 servers?

The user token USB key is typically needed for certain firmware updates to ensure authorized access. If you are prompted for this key, it indicates that the update process requires additional authentication, which may not allow for updates without it. [community thread]

How do I install the HPE MR416i-o Gen 11 x16 Lanes Cache OCP SPDM Storage Controller in an HPE Proliant DL380 Gen 11 Server?

After inserting the card, ensure that the cable connections are configured correctly as per the updated specifications. If the server does not recognize the controller, refer to the manufacturer's guidelines or instructional videos for proper setup. [community thread]

What is the part number for a secondary riser card for the ProLiant DL380 Gen10?

For the ProLiant DL380 Gen10, the recommended part number for a secondary riser card is HPE DL Gen10 x8/x16/x8 Riser Kit: 870548-B21. This riser supports various configurations and allows for the installation of additional PCIe cards. [community thread]

What distinguishes the DL385 G10 from the DX385 V10 models?

The DL385 Gen10 and DX385 V10 share the same system board but are optimized for different applications; the DL385 is for general enterprise use while the DX385 is designed for hyperconverged infrastructure with Nutanix. Although they have similar hardware, the DX385 includes specific firmware and software enhancements for Nutanix environments. When replacing parts, ensure compatibility with the intended model and consider any necessary adjustments to the system board's settings. [community thread]

Can I reuse the heatsink when upgrading from a 6100 series CPU to a 6200 series CPU in a DL380 Gen10 server?

Reusing the heatsink is acceptable if both CPUs have the same Thermal Design Power (TDP). In this case, since both the 6136 and 6242 CPUs have a TDP of 150W, the heatsink can be reused. However, if you consider using a CPU with a higher TDP, such as the 6143 at 205W, a different heatsink that meets the higher TDP requirement would be necessary. [community thread]

Why is the temperature sensor for the LOM card not appearing in the DL380 Gen10 Plus server?

The absence of the temperature sensor for the LOM card in the DL380 Gen10 Plus is due to differences in hardware design between the two server models. While the DL385 Gen10 Plus recognizes the sensor, the DL380 does not include it in its system layout, resulting in the sensor being marked as 'absent' despite the card functioning properly. [community thread]

Why is my HP DL160 G10 server experiencing high fan noise during operation?

High fan noise on the HP DL160 G10 can often be mitigated by updating the firmware using the Gen10/Gen10 Plus Service Pack for ProLiant. Additionally, installing the Agentless Management Service for Windows may help reduce fan speed to normal levels. [community thread]

How can I access iLO on a Proliant DL360 Gen10 configured with Shared LOM?

To access iLO on a Proliant DL360 Gen10 with Shared LOM, ensure you are using the dedicated iLO NIC port labeled 'iLO' for a direct connection. If using the shared LOM port, be aware that both server and iLO traffic will share the same network connection, which may complicate access. [community thread]

Why can't I create RAID1 or RAID10 on my DL360 Gen11 with MR416i?

If the MR Storage Admin interface is not allowing you to select RAID1 or RAID10, ensure that all drives are properly configured and recognized as 'unconfigured good.' Additionally, check for any settings or permissions that may be restricting access to these RAID options, as they may differ between systems. [community thread]

Can I use the HPE NS204i-u Gen11 Boot Controller without RAID 1 for my PVE installation?

The NS204i-u controller is designed to operate in a mirrored RAID 1 configuration for boot drives, so you cannot use the two SSDs as independent drives. However, you can use the controller for booting and utilize separate NVMe drives for your data storage needs. [community thread]

Why are no drives detected when installing the OS on a DL380 Gen10 server?

If no drives are found during the OS installation, ensure that only supported media is connected. Additionally, verify that the RAID configuration is correctly set up and that the drives are properly recognized in the server's management interface. [community thread]

Are generic NVMe drives compatible with the DL360 Gen11 server?

It is advisable to use only qualified and supported drives in HPE servers, as generic drives may not function properly and issues may not be logged accurately. For compatibility details, refer to the HPE DL360 Gen11 QuickSpecs document. [community thread]

Can I add an NVME backplane to a Proliant DL360 G10 server?

Yes, you can install an NVME backplane on a Proliant DL360 G10 server, but ensure you select the correct parts. Recommended components include the primary riser board (part number 875548-001) and the secondary riser board (part number 875549-001). Additionally, consider the full NVME backplane kit (part number 867974-B21) for compatibility. [community thread]

Do I need a SAS Expander card for the DL380 Gen10 with a P408i-a controller when using a 12LFF backplane?

Yes, to connect all 12 drives on the 12LFF backplane with the P408i-a controller, you will need the 870549-B21 SAS Expander card. This card allows for the additional SAS connections required for full functionality. [community thread]

What should I do if my HPE ProLiant DL360 Gen10 shows no physical drive found?

First, verify the smart array controller in use and ensure that the S100i is enabled in the BIOS, as it is disabled by default. If the drive is properly connected and still not recognized, consider testing with a different drive, as the original may be defective. [community thread]

Can I add an additional drive cage to my DL380 Gen10 server to support more drives?

The HPE Smart Array P408i-a SR Gen10 controller only supports one drive bay connection. To add a second drive bay, you will need to use a SAS expander or a second controller. [community thread]

What is the maximum number of disks allowed in a single RAID group for the DL380 Gen10?

The maximum number of disks in a single RAID group for the DL380 Gen10 varies by model. For specific details, refer to the HPE Smart Array SR Gen10 User Guide, particularly on page 9. [community thread]

Why is my DL325 Gen10 Plus server's fan running at high speed and making loud noises?

The loud noise from the fans is likely a response to storage degradation. It's important to check the storage health and address any issues to reduce fan speed and noise. [community thread]

Is a PCIe expander card necessary when using the HPE ProLiant DL380 Gen10 with additional SFF cages?

Yes, when configuring the DL380 Gen10 with additional SFF cages, a PCIe expander card is required since the default P408i-a controller only supports 8 drives. To utilize all 16 SFF slots, you should either include the expander card or opt for a different controller model that supports more connections. [community thread]

How can I view the full POST sequence on a DL380 Gen10 server without iLO access?

To see the full POST sequence on the DL380 Gen10, briefly press the UID button. This should allow the sequence to display on the screen instead of in a thumbnail view. [community thread]

How can I resolve installation failures when updating the iDRAC Service Module on a PowerEdge R7525?

To fix installation issues with the iDRAC Service Module, try reinstalling the Dell LifeCycle Controller and then using the DSU utility to upgrade. Select the 'OpenManage | iDRAC Service Module' and choose the 'Dell iDRAC Service Module Embedded Package v5.3.0.0' for installation, which should succeed and allow you to verify the latest version in the iDRAC settings. [community thread]

Can I use a U.2 cable with a U.3 drive cage for my DL325 Gen11 server?

U.2 and U.3 connectors are not directly compatible due to differences in their signal and power specifications. For your DL325 Gen11, you should look for a Low Profile SlimSAS to NVMe U.3 cable to ensure proper connectivity between the storage controller and the drive cage. [community thread]

What should I do if my R650 or R6525 server shows a CPU VRM voltage error and won't power on?

If your server fails to power on and displays a CPU VRM voltage error, try booting with a minimal memory configuration. If the server starts, systematically test the memory modules by swapping them out to identify any faulty DIMMs, as issues with memory can cause voltage errors. [community thread]

Where can I find the location of temperature sensors in DL380 Gen10 and DL580 Gen10 servers?

You can access the iLO Web GUI, which provides a 3D map and a table detailing the positions and values of all temperature sensors. [community thread]

Why can't my ProLiant DL180 Gen10 detect newly added drives?

The ProLiant DL180 Gen10 with the HPE Smart Array S100i SR Gen10 controller is limited to supporting only SATA hard drives. If you are using SAS drives, they will not be recognized by the system. [community thread]

What should I do if I encounter an error when logging into iLO5 on a DL360 Gen10 server?

If you receive an error message indicating that iLO is not ready, try enabling Cloudflared and using SOCKS for your connection. This should resolve the login issue. [community thread]

What is the difference between standard and high-performance fans for the DL380 Gen10, and are they louder during idle operation?

There is generally no significant difference in noise levels between standard and high-performance fans, especially in a noisy datacenter environment. If fan noise is a concern, consider adjusting the BIOS settings for better control. [community thread]

Can I use a different part number to replace a failed SSD in a RAID 5 array on a DL380 Gen10 server?

Yes, you can replace a failed SSD with a different model, such as P18432-B21, which is compatible with your existing drives. Just be aware that all drives will operate at the performance level of the slowest one in the array. After replacing the failed drive, the array should automatically rebuild without any additional steps required. [community thread]

What should I do if my HP ML110 Gen10 server firmware update is stuck?

If the firmware update process appears to be frozen and has not progressed for an extended period, it is generally advisable to power off the server and restart it. However, be aware that interrupting a firmware update can potentially lead to issues, so proceed with caution. [community thread]

What cables are needed to connect the NS204i-u hot-plug boot device to the HPE Proliant DL20 Gen11 mainboard?

The required cables for connecting the NS204i-u to the mainboard are P63684-001 and P63685-001, as specified in the HPE documentation. For further assistance, you can refer to the HPE support links that provide additional information. [community thread]

What should I do if my DL320 Gen11 server is experiencing NVMe device disconnections?

If you encounter NVMe disconnection issues, try powering down individual NVMe drives via ILO to identify the faulty component. Additionally, reseating the NVMe drives and their cables may resolve the problem, as connection issues can sometimes be the underlying cause. [community thread]

Is the Intel x520 network adapter compatible with the Dell PowerEdge R760sx server?

Compatibility for the Intel x520 network adapter with the Dell PowerEdge R760sx may vary based on the specific model of the adapter. It is recommended to verify the part number and consult Dell's compatibility resources for the most accurate information. [community thread]

Why does my server show 16 cores in BIOS but only 1 core in Windows Task Manager?

This is not normal; you should see 1 socket, 16 cores, and 32 logical processors in Task Manager. Check your Windows settings or BIOS configuration to ensure all cores are enabled. [community thread]