The reboot may be due to the UPS outputting a simulated sine wave, which can cause the R440's power supply to lose sync and restart. Ensure the UPS provides a pure sine wave output and has a transfer time of less than 4 ms. Additionally, check for firmware updates for both the UPS and the R440. [community thread]
If your server shows no signs of power, indicated by blinking LEDs, it may be experiencing a 5V SW fault. Begin troubleshooting by disconnecting all USB devices, checking for shorts in the iDRAC Direct cable and video connections, and removing the front control panel cable. If the issue persists after these steps, consider testing with minimal components or replacing the motherboard. [community thread]