Part number 5NV48 · also known as 05NV48
Request a quote
(1-3 DAYS) 05NV48 (DELL POWEREDGE R450 RISER CAGE 2 [2] TWO LOW PROFILE HALF HEIGHT SLOTS BRACKET ASSM)
Configure a complete server with live pricing
To resolve HWC8010 and UEFI0459 errors, first reseat the PERC 755 RAID card and any associated risers, ensuring they are in the correct slots. Next, access the BIOS/iDRAC settings to accept the current hardware configuration as valid. If the issue persists, check for firmware updates or temporarily remove the PERC card to see if the error clears. [community thread]
The H755N requires NVMe-specific cables, which are different from those used for SAS PERC cards. Ensure that your server's configuration supports the necessary backplane for the H755N, as it typically accommodates specific drive setups. [community thread]
To address this issue, ensure that your DIMMs are properly populated according to the server's memory guidelines. Check the BIOS version and verify the specifications of the installed DIMMs, as only certain capacities are supported for 2R DIMMs. [community thread]
Discrepancies in IPMI sensor data among identical R450 servers can occur due to variations in the tools used for monitoring. Using a more reliable command-line tool like 'ipmitool' may provide consistent and comprehensive sensor information across all servers. [community thread]
No, to utilize a second PCIe card in slot 3 via riser 2, a second CPU is necessary. Without the second CPU, slot 3 will not function, and you will only have access to slot 1. [community thread]