HP P03178-B21 HPE 1000W Flex Slot Titanium Hot Plug Power Supply Kit

Part number P03178-B21

Price: $278.60 USD

HP HPE 1000W Flex Slot Titanium Hot Plug Power Supply Kit

Specifications

inputAC
watts1000
redundantTrue
efficiencyTitanium
component typehot_plug
compatibility familyhpe-1000w

Works with these servers

Configure a complete server with live pricing

Frequently asked questions

Why does Hyper-V installation fail with a message about virtualization not being enabled despite it appearing enabled in the BIOS?

This issue may arise if the workload profile in the BIOS has disabled virtualization options. To resolve this, access the BIOS settings, navigate to the workload profile, and switch to either 'Virtualization - Power Efficient' or 'Virtualization - Max Performance'. If options remain greyed out, resetting the BIOS to default settings may also help. [community thread]

Why is my DL360 Gen11 server not recognizing HPE NVMe drives?

Ensure that Intel VMD and Intel VROC are enabled in the RBSU settings. Additionally, verify that the NVMe drives are properly connected to the correct backplane and that the cabling is intact. If issues persist, consult the Intel VROC documentation for further troubleshooting steps. [community thread]

What should I do if the fans on my HPE ProLiant DL360 Gen11 are running at medium speed frequently?

To troubleshoot the fan speed issue, access iLO 6 to monitor fan speeds, thermal readings, and event logs when the fans increase in speed. Ensure that iLO 6, BIOS, and SPP are updated to their latest versions, and consider analyzing the AHS log for any components causing the issue. You can also adjust fan settings in the Power & Thermal section to optimize cooling performance. [community thread]

Why does iLO indicate a critical status for the storage controller when ssacli shows everything is fine?

This issue is known to occur with HPE ProLiant Gen10/Gen10 Plus servers, where iLO may incorrectly report a critical status due to stale sensor data or misinterpretation of cache states. To resolve this, perform a full power cycle of the server to clear sensor states, or use the iLO CLI to force a hardware health rescan. Additionally, ensure that both iLO and Smart Array controller firmware are updated to the latest versions. [community thread]

Can a DL380 Gen10 server boot with only the second CPU installed?

No, the server requires the first CPU socket to be populated for it to function correctly. Operating with only the second CPU installed is not a supported configuration and will prevent the server from booting. [community thread]