Frequently asked questions

What GPUs are compatible with the PowerEdge R7525 and what is the maximum power draw?

For compatible GPUs and recommended slots, consult the technical guide, specifically page 27. The maximum power draw for GPUs is detailed in the table on page 7. [community thread]

What does the error 'CPU 1 VCCIO PG Voltage Is Outside of Range' mean on a PowerEdge R760?

This error is typically associated with issues in the motherboard's voltage regulation or CPU seating. To troubleshoot, perform a power drain, check for firmware updates, and inspect the CPU for any bent pins or debris. If the problem continues, the motherboard may need to be examined. [community thread]

Why does the iDRAC display CPU speed in MT/s instead of MHz or GHz on my server?

This is a known presentation error in iDRAC9 where the CPU speed is incorrectly labeled as MT/s instead of MHz or GHz. It does not indicate a hardware or firmware issue, but rather a unit-labeling mistake in the user interface. [community thread]

Can the R760 server support two Nvidia L40 video cards?

Yes, the R760 server with dual CPUs can accommodate two Nvidia L40 GPUs, as they are double-width and within the power specifications. Ensure you have a power supply of at least 1600W and the appropriate GPU riser kit, power cables, and cooling components for optimal performance. [community thread]

What should I do if my Dell R450 shows HWC8010 and UEFI0459 errors during startup?

To resolve HWC8010 and UEFI0459 errors, first reseat the PERC 755 RAID card and any associated risers, ensuring they are in the correct slots. Next, access the BIOS/iDRAC settings to accept the current hardware configuration as valid. If the issue persists, check for firmware updates or temporarily remove the PERC card to see if the error clears. [community thread]