HPE P52416-B21

Part number P52416-B21

Price: $202.82 USD

− For 8 SFF x4 U.3 drive cage selection with 2 SFF Drive cage: If MR416i-p/ MR216i-p and MR416i-o/ MR216i-o/ MR408i-o are selected, then both "HPE DL360 Gen11 8 SFF PCIe Cable Ki/ P48909-B21 or HPE DL360 Gen11 OROC TM Cable Kit/ P52416-B21" and "HPE DL360 Gen11 2 SFF TM Cable Kit/ P48910-B21" must be selected.

Specifications

component typemechanical

Works with these servers

Configure a complete server with live pricing

Frequently asked questions

What should I do if my HP Proliant DL380 Gen10 fans are excessively noisy after an ILO5 firmware update?

If you experience increased fan noise following an ILO5 firmware update to version 3.04, downgrading to version 3.03 may resolve the issue. You can download the previous version and update the firmware through the ILO5 dashboard to restore normal fan operation. [community thread]

Why are only 10 out of 12 drives detected on my DL380 Gen10 with the S100i controller?

The S100i controller may not support all 12 drives due to hardware limitations. It is advisable to check the compatibility of the drives being used and consider upgrading to a dedicated Smart Array controller for full support of all 12 drives. [community thread]

What should I do if I encounter a REST API error with my ProLiant DL380 Gen10 server's iLO firmware?

To resolve the REST API error, try resetting the iLO from the console and then SSH into the iLO to execute the command 'oemhp_clearRESTAPIstate'. After that, reboot both the server and the iLO by shutting down the server, disconnecting all power sources and cables, reconnecting them, and powering the server back on. [community thread]

Why does my ML350 Gen10 server power up all fans to maximum every 26 hours?

This issue may be related to firmware or embedded system settings rather than user activity. To troubleshoot, check the iLO logs during the fan spike, verify BIOS/iLO versions, consider downgrading iLO for testing, ensure AMS is functioning properly, and monitor hardware sensors. If the problem persists, contact HPE Support for further assistance. [community thread]

What should I do if I can't re-add my DL380 Gen10 servers to OneView?

Ensure that your network settings are correct and that the servers are reachable. You may want to review the documentation for adding servers to OneView and consider resetting the iLO configuration or checking for any certificate issues. [community thread]