Dell 700W Titanium PSU (HLAC)

Part number 3D09N · also known as 373CM · 42P96

Request a quote

Dell 700W Titanium HLAC-only (240V required) hot-plug PSU, 15G/16G/17G CFF

Specifications

inputAC
watts700
hlac onlyTrue
redundantTrue
efficiencyTitanium
form factorCFF
requires 240vTrue
component typehot_plug
compatibility familydell-700w
psu compatibility familydell-15g-16g-17g-cff

Works with these servers

Configure a complete server with live pricing

Frequently asked questions

What does the error 'CPU 1 VCCIO PG Voltage Is Outside of Range' mean on a PowerEdge R760?

This error is typically associated with issues in the motherboard's voltage regulation or CPU seating. To troubleshoot, perform a power drain, check for firmware updates, and inspect the CPU for any bent pins or debris. If the problem continues, the motherboard may need to be examined. [community thread]

Can the R760 server support two Nvidia L40 video cards?

Yes, the R760 server with dual CPUs can accommodate two Nvidia L40 GPUs, as they are double-width and within the power specifications. Ensure you have a power supply of at least 1600W and the appropriate GPU riser kit, power cables, and cooling components for optimal performance. [community thread]

What do the LED codes on the R660 motherboard indicate when the server fails to boot?

The LED codes on the R660 motherboard can signal various issues, such as a 5V switch fault or problems with connected USB devices, iDRAC cables, or the rear I/O card. To troubleshoot, perform a flea power drain, clear the NVRAM, and test with only the minimum components necessary for POST. If the server still does not boot, further inspection of the components may be required. [community thread]

What power cable is needed to install a Nvidia A100-SXM4-40GB in a R760 server?

To connect the Nvidia A100-SXM4-40GB GPU in a R760 server, you will need the appropriate power cable. The correct part numbers to look for are 9PVH2 for Riser 4 and CPH58 for Riser 1, but it's advisable to verify compatibility before purchasing. [community thread]

What should I do if my PowerEdge R250 won't power on after adding components?

If your server shows no signs of power, indicated by blinking LEDs, it may be experiencing a 5V SW fault. Begin troubleshooting by disconnecting all USB devices, checking for shorts in the iDRAC Direct cable and video connections, and removing the front control panel cable. If the issue persists after these steps, consider testing with minimal components or replacing the motherboard. [community thread]