DELL PCIe NVMe / SAS3 / SATA3 HARD DRIVE BACKPLANE 2.5 INCH

Part number 8DJ9J · also known as SATA3

Price: $768.60 USD

DELL PCIe NVMe / SAS3 / SATA3 HARD DRIVE BACKPLANE 2.5 INCH SFF 8 BAY V2 FOR DELL EMC POWEREDGE R760 / R760XA / R7625 - HDD BP SMALL FORM FACTOR 8B / 8SFF - PCI-E NON VOLATILE MEMORY EXPRESS / SAS / SATA - ( ASSY, PWA, BKPLN, 2U, 8X2.5, 15G, V2 )

Specifications

interfaceNVMe
form factor2.5"
component typebackplane

Works with these servers

Configure a complete server with live pricing

Frequently asked questions

What does the error 'CPU 1 VCCIO PG Voltage Is Outside of Range' mean on a PowerEdge R760?

This error is typically associated with issues in the motherboard's voltage regulation or CPU seating. To troubleshoot, perform a power drain, check for firmware updates, and inspect the CPU for any bent pins or debris. If the problem continues, the motherboard may need to be examined. [community thread]

Can the R760 server support two Nvidia L40 video cards?

Yes, the R760 server with dual CPUs can accommodate two Nvidia L40 GPUs, as they are double-width and within the power specifications. Ensure you have a power supply of at least 1600W and the appropriate GPU riser kit, power cables, and cooling components for optimal performance. [community thread]

What parts are needed to install a GPU on a PowerEdge R750XS server?

The PowerEdge R750XS does not have a specific GPU enablement kit, and there is no documented support for GPU configurations. For detailed information, refer to the technical guide provided by the manufacturer. [community thread]

What components are necessary for installing an NVIDIA L4 GPU in a PowerEdge R760xd2 server?

To install an NVIDIA L4 GPU in a PowerEdge R760xd2, you will need Riser Config 3A, a GPU enablement kit (part number 470-BBWW), and the NVIDIA L4 GPU itself (part number 490-BJRQ). Ensure that your server's BIOS and iDRAC are updated, and a power supply of 1100W or more is recommended for stable operation. [community thread]

What do the LED codes on the R660 motherboard indicate when the server fails to boot?

The LED codes on the R660 motherboard can signal various issues, such as a 5V switch fault or problems with connected USB devices, iDRAC cables, or the rear I/O card. To troubleshoot, perform a flea power drain, clear the NVRAM, and test with only the minimum components necessary for POST. If the server still does not boot, further inspection of the components may be required. [community thread]